Abstract

Histological imaging is still considered the gold standard for analysing bone formation around metallic implants. Generally, a limited number of histological sections per sample are used for the approximation of mean values of peri-implant bone formation. In this study we compared statistically the results of bone-implant contact (BIC) and bone-implant volume (BIV) obtained by histological sections, with those obtained by X-ray absorption images from synchrotron radiation micro-computed tomography (SRµCT) using osseointegrated screw-shaped implants from a mini-pig study. Comparing the BIC results of 3-4 histological sections per implant sample with the appropriate 3-4 SRµCT slices showed a non-significant difference of 1.9 % (p = 0.703). The contact area assessed by the whole 3D information from the SRµCT measurement in comparison to the histomorphometric results showed a non-significant difference in BIC of 4.9 % (p = 0.171). The amount of the bone-implant volume in the histological sections and the appropriate SRµCT slices showed a non-significant difference by only 1.4 % (p = 0.736) and also remains non-significant with 2.6 % (p = 0.323) using the volumetric SRµCT information. We conclude that for a clinical evaluation of implant osseointegration with histological imaging at least 3-4 sections per sample are sufficient to represent the BIC or BIV for a sample. Due to the fact that in this study we have found a significant intra-sample variation in BIC of up to ± 35 % the selection of only one or two histological sections per sample may strongly influence the determined BIC.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22492016     DOI: 10.22203/ecm.v023a18

Source DB:  PubMed          Journal:  Eur Cell Mater        ISSN: 1473-2262            Impact factor:   3.942


  23 in total

1.  Osseointegration of titanium implants with SLAffinity treatment: a histological and biomechanical study in miniature pigs.

Authors:  Keng-Liang Ou; Heng-Jui Hsu; Tzu-Sen Yang; Yun-Ho Lin; Chin-Sung Chen; Pei-Wen Peng
Journal:  Clin Oral Investig       Date:  2015-10-28       Impact factor: 3.573

2.  Coating with artificial matrices from collagen and sulfated hyaluronan influences the osseointegration of dental implants.

Authors:  Matthias C Schulz; Paula Korn; Bernd Stadlinger; Ursula Range; Stephanie Möller; Jana Becher; Matthias Schnabelrauch; Ronald Mai; Dieter Scharnweber; Uwe Eckelt; Vera Hintze
Journal:  J Mater Sci Mater Med       Date:  2013-10-11       Impact factor: 3.896

3.  Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis.

Authors:  He-Kyong Kang; Tien-Min Chu; Paul Dechow; Kelton Stewart; Hee-Moon Kyung; Sean Shih-Yao Liu
Journal:  Eur J Orthod       Date:  2015-04-23       Impact factor: 3.075

4.  Sequential osseointegration from osseohealing to osseoremodeling - Histomorphological comparison of novel 3D porous and solid Ti-6Al-4V titanium implants.

Authors:  Alice Frosch; Sebastian Krohn; Gottfried Buchhorn; Wolfgang Lehmann; Karl-Heinz Frosch; László Füzesi; Stephan Frosch
Journal:  Histol Histopathol       Date:  2021-03-29       Impact factor: 2.303

5.  Osseointegration of a novel 3D porous Ti-6Al-4V implant material - Histomorphometric analysis in rabbits.

Authors:  Stephan Frosch; Gottfried Buchhorn; Sebastian Krohn; Wolfgang Lehmann; Karl-Heinz Frosch; László Füzesi; Alice Frosch
Journal:  Histol Histopathol       Date:  2021-05-11       Impact factor: 2.303

6.  Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

Authors:  Sung-Won Kang; Woo-Jin Lee; Soon-Chul Choi; Sam-Sun Lee; Min-Suk Heo; Kyung-Hoe Huh; Tae-Il Kim; Won-Jin Yi
Journal:  Imaging Sci Dent       Date:  2015-03-13

7.  Quantification of osseointegration of plasma-polymer coated titanium alloyed implants by means of microcomputed tomography versus histomorphometry.

Authors:  Carolin Gabler; Carmen Zietz; Richard Bieck; Rebecca Göhler; Tobias Lindner; Maximilian Haenle; Birgit Finke; Jürgen Meichsner; Holger Testrich; Mathias Nowottnick; Bernhard Frerich; Rainer Bader
Journal:  Biomed Res Int       Date:  2015-04-30       Impact factor: 3.411

8.  Osseointegration of TI6Al4V dental implants modified by thermal oxidation in osteoporotic rabbits.

Authors:  Oscar G Bodelón; Celia Clemente; Miguel Angel Alobera; Soledad Aguado-Henche; María Lorenza Escudero; María Cristina García Alonso
Journal:  Int J Implant Dent       Date:  2016-07-21

9.  A comparison of micro-CT and histomorphometry for evaluation of osseointegration of PEO-coated titanium implants in a rat model.

Authors:  Tao He; Cong Cao; Zhiguo Xu; Gen Li; Huiliang Cao; Xuanyong Liu; Chao Zhang; Yuqi Dong
Journal:  Sci Rep       Date:  2017-11-24       Impact factor: 4.379

10.  A systematic review on the effect of inorganic surface coatings in large animal models and meta-analysis on tricalcium phosphate and hydroxyapatite on periimplant bone formation.

Authors:  Jeanne-Marie Damerau; Susanne Bierbaum; Daniel Wiedemeier; Paula Korn; Ralf Smeets; Gregor Jenny; Johanna Nadalini; Bernd Stadlinger
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2021-07-16       Impact factor: 3.405

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.