Comparison of pulse oximeters: accuracy at low arterial pressure in volunteers.

R J Falconer1, B J Robinson.   

Abstract

A laboratory model was developed of limb hypoperfusion in volunteers, using parital occlusion of the brachial artery with consequent reduction in radial artery pulse pressure. This was used to compare the function of 13 pulse oximeters and the effect of reduced pulse pressure and mild hypoxia on these devices. With the exception of one device, all the pulse oximeters studied demonstrated similar accuracies at pulse pressures exceeding 20 mm Hg. There were however, significant differences between several of the pulse oximeters in both ability to display readings and accuracy of readings displayed when brachial artery occlusion reduced radial artery pulse pressures equal to or less than 20 mm Hg.

Entities:  

Mesh:

Year:  1990        PMID: 2248826     DOI: 10.1093/bja/65.4.552

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  6 in total

1.  Arterial line for monitoring SpO2 in patients with ischemic peripheries.

Authors:  Goneppanavar Umesh; Kaur Jasvinder; Shetty Nanda; Shetty Ranjan
Journal:  J Clin Monit Comput       Date:  2010-07-16       Impact factor: 2.502

2.  Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: Is the perfusion index of any value?

Authors:  Helmut D Hummler; Anja Engelmann; Frank Pohlandt; Josef Högel; Axel R Franz
Journal:  Intensive Care Med       Date:  2006-06-30       Impact factor: 17.440

3.  Uses and abuses of pulse oximetry.

Authors:  D G Kruchek
Journal:  Arch Dis Child       Date:  1996-08       Impact factor: 3.791

4.  Multiple scattering effect in transmission pulse oximetry.

Authors:  I Fine; A Weinreb
Journal:  Med Biol Eng Comput       Date:  1995-09       Impact factor: 2.602

5.  Misleading information from pulse oximetry and the usefulness of continuous blood gas monitoring in a post cardiac surgery patient.

Authors:  J P Benson; B Venkatesh; V Patla
Journal:  Intensive Care Med       Date:  1995-05       Impact factor: 17.440

6.  The new trauma score (NTS): a modification of the revised trauma score for better trauma mortality prediction.

Authors:  Jin Hee Jeong; Yong Joo Park; Dong Hoon Kim; Tae Yun Kim; Changwoo Kang; Soo Hoon Lee; Sang Bong Lee; Seong Chun Kim; Daesung Lim
Journal:  BMC Surg       Date:  2017-07-03       Impact factor: 2.102

  6 in total