Literature DB >> 22456944

Orbscan II and double-K method for IOL calculation after refractive surgery.

Sérgio Kwitko1, Diane R Marinho, Samuel Rymer, Norton Severo, Carlos G Arce.   

Abstract

BACKGROUND: Precise IOL calculation in post-refractive surgery patients is still a challenge for the cataract surgeon. The purpose of this study is to test whether adding Orbscan II values into the double-K method improves IOL calculation in this group of patients.
METHODS: A prospective study with 43 eyes previously submitted to refractive surgery that underwent cataract extraction. IOL calculation was performed with double-K method. Post-K value was derived from Orbscan total-mean power map. The average corneal curvature of the general population (43.8D) was used as the pre-K value. Refraction results 30 days after surgery were compared with refraction that would be obtained if we used: (1) post-K values from keratometry, (2) post-K values from topography, and (3) pre-K values from Orbscan total-mean power. Anterior chamber depth measures obtained with the IOL Master and Orbscan II were compared.
RESULTS: Mean postoperative spherical equivalent (SE) was -0.25 ± 1.10 D in eyes submitted to radial keratotomy , -1.04 ± 1.42 D in eyes previously submitted to myopic Lasik, and +0.05 ± 1.76 D in those submitted to hyperopic surgeries. Had we inputted post-K values derived from keratometer and from topography, we would have obtained significantly higher postoperative refractive errors in eyes previously submitted to myopic refractive surgery (p < 0.05). Refractions using pre-K derived from the central 8 mm Orbscan instead of 43.8 D were similar in all studied groups (p > 0.05). Anterior chamber depth measured with IOL Master or Orbscan were similar.
CONCLUSIONS: Orbscan measurements used as the post-K values into the double-K method provide a precise IOL calculation, especially in post myopic refractive surgery patients.

Entities:  

Mesh:

Year:  2012        PMID: 22456944     DOI: 10.1007/s00417-012-1974-z

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  20 in total

1.  Simple regression formula for intraocular lens power adjustment in eyes requiring cataract surgery after excimer laser photoablation.

Authors:  Samuel Masket; Seth Everett Masket
Journal:  J Cataract Refract Surg       Date:  2006-03       Impact factor: 3.351

2.  A direct method to measure the power of the central cornea after myopic laser in situ keratomileusis.

Authors:  Sergio Sónego-Krone; Gerson López-Moreno; Oscar V Beaujon-Balbi; Carlos G Arce; Paulo Schor; Mauro Campos
Journal:  Arch Ophthalmol       Date:  2004-02

3.  Comparative estimation of anterior chamber depth by ultrasonography, Orbscan II, and IOLMaster.

Authors:  Aravind R Reddy; Milind V Pande; Paul Finn; Hazem El-Gogary
Journal:  J Cataract Refract Surg       Date:  2004-06       Impact factor: 3.351

Review 4.  Orbscan computerized topography: attributes, applications, and limitations.

Authors:  Gerard Cairns; Charles N J McGhee
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

5.  Determining corneal power using Orbscan II videokeratography for intraocular lens calculation after excimer laser surgery for myopia.

Authors:  Mujtaba A Qazi; Irwin Y Cua; Cynthia J Roberts; Jay S Pepose
Journal:  J Cataract Refract Surg       Date:  2007-01       Impact factor: 3.351

6.  Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula.

Authors:  Wolfgang Haigis
Journal:  J Cataract Refract Surg       Date:  2008-10       Impact factor: 3.351

7.  Corneal power measurements with the Pentacam Scheimpflug camera after myopic excimer laser surgery.

Authors:  Giacomo Savini; Piero Barboni; Vincenzo Profazio; Maurizio Zanini; Kenneth J Hoffer
Journal:  J Cataract Refract Surg       Date:  2008-05       Impact factor: 3.351

8.  Intraocular lens power calculation after laser in situ keratomileusis for myopia and hyperopia: a standardized approach.

Authors:  V Feiz; M J Mannis; F Garcia-Ferrer; G Kandavel; J K Darlington; E Kim; J Caspar; J L Wang; W Wang
Journal:  Cornea       Date:  2001-11       Impact factor: 2.651

9.  Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis.

Authors:  H John Shammas; Maya C Shammas; Antoine Garabet; Jenny H Kim; Abraham Shammas; Laurie LaBree
Journal:  Am J Ophthalmol       Date:  2003-09       Impact factor: 5.258

10.  Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK.

Authors:  Li Wang; Marc A Booth; Douglas D Koch
Journal:  Ophthalmology       Date:  2004-10       Impact factor: 12.079

View more
  5 in total

1.  Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery.

Authors:  Sabong Srivannaboon; Chareenun Chirapapaisan
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-05       Impact factor: 3.117

2.  The distribution of orbscan indices in young population.

Authors:  Hassan Hashemi; Mehdi Khabazkhoob; Negareh Yazdani; Hadi Ostadimoghaddam; Payam Nabovati; Raheleh Moravej; AbbasAli Yekta
Journal:  J Curr Ophthalmol       Date:  2016-08-31

3.  Cataract Surgery following Sequential Myopic and Hyperopic LASIK.

Authors:  Tao Ming Thomas Chia; Hoon C Jung
Journal:  Case Rep Ophthalmol       Date:  2018-05-24

4.  Improving accuracy of corneal power measurement with partial coherence interferometry after corneal refractive surgery using a multivariate polynomial approach.

Authors:  Michele Lanza; Robert Koprowski; Mario Bifani Sconocchia
Journal:  Biomed Eng Online       Date:  2018-08-13       Impact factor: 2.819

5.  Effects and risks of 3.2-mm transparent corneal incision phacoemulsification for cataract after radial keratotomy.

Authors:  Jin-da Wang; Xue Liu; Jing-Shang Zhang; Ying Xiong; Jing Li; Xiao-Xia Li; Jing Zhao; Qi-Sheng You; Yao Huang; Mark Espina; Vishal Jhanji; Xiu-Hua Wan
Journal:  J Int Med Res       Date:  2020-03       Impact factor: 1.671

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.