Literature DB >> 2245503

Relation between transcardiac and transthoracic current during defibrillation in humans.

B B Lerman1, O C Deale.   

Abstract

Conceptually, transthoracic defibrillation threshold current can be considered a function of at least two quantities. It is directly proportional to the transcardiac threshold current and inversely proportional to the transcardiac current fraction (FC) or the ratio of transcardiac and transthoracic current. Although experimental and theoretical estimates of FC have been as high as 45%, previous measurements in humans have not been made. This study was designed to quantify FC in humans. During intraoperative testing of the automatic implantable cardioverter defibrillator, transthoracic rescue shocks of 200-400 J were delivered when the device failed to defibrillate. Simultaneous transthoracic voltage (VT) and transcardiac voltage (VC) between two implanted epicardial patch electrodes were measured. The ratio, VC/VT, was 0.04 +/- 0.03 (mean +/- SD) in 10 patients. In 16 dogs, a comparison was made between direct measurement of FC and VC/VT. FC was determined with a specially designed electrode system, which was calibrated to account for field distortion introduced by the electrodes. There was no significant difference between FC and VC/VT, which were both approximately 0.05, suggesting that VC/VT was statistically equivalent to FC. The results of this study, therefore, indicate that during transthoracic defibrillation in humans, approximately 4% of transthoracic current traverses the heart. This relatively small percentage of current results from the existence of parallel pathways, such as the thoracic cage and lungs, which shunt current around the heart.

Entities:  

Mesh:

Year:  1990        PMID: 2245503     DOI: 10.1161/01.res.67.6.1420

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  14 in total

Review 1.  Cardiac stimulation with high voltage discharge from stun guns.

Authors:  Kumaraswamy Nanthakumar; Stephane Massé; Karthikeyan Umapathy; Paul Dorian; Elias Sevaptsidis; Menashe Waxman
Journal:  CMAJ       Date:  2008-05-01       Impact factor: 8.262

2.  Cardioversion: past, present, and future.

Authors:  Ivan Cakulev; Igor R Efimov; Albert L Waldo
Journal:  Circulation       Date:  2009-10-20       Impact factor: 29.690

3.  The 1998 European Resuscitation Council guidelines for adult advanced life support. Advanced Life Support Working Group of the European Resuscitation Council.

Authors: 
Journal:  BMJ       Date:  1998-06-20

4.  The subcutaneous defibrillator will replace the transvenous defibrillator.

Authors:  Ian Crozier
Journal:  J Interv Card Electrophysiol       Date:  2011-04-27       Impact factor: 1.900

5.  Association between transthoracic impedance and electrical cardioversion success with biphasic defibrillators: An analysis of 1055 shocks for atrial fibrillation and flutter.

Authors:  Mouhannad M Sadek; Varsha Chaugai; Mark J Cleland; Timothy J Zakutney; David H Birnie; F Daniel Ramirez
Journal:  Clin Cardiol       Date:  2018-05-11       Impact factor: 2.882

6.  Role of peak current in conversion of patients with ventricular fibrillation.

Authors:  Venkataraman Anantharaman; Paul Weng Wan; Seow Yian Tay; Peter George Manning; Swee Han Lim; Siang Jin Terrance Chua; Tiru Mohan; Antony Charles Rabind; Sudarshan Vidya; Ying Hao
Journal:  Singapore Med J       Date:  2017-07       Impact factor: 1.858

7.  Transmural recording of shock potential gradient fields, early postshock activations, and refibrillation episodes associated with external defibrillation of long-duration ventricular fibrillation in swine.

Authors:  James D Allred; Cheryl R Killingsworth; J Scott Allison; Derek J Dosdall; Sharon B Melnick; William M Smith; Raymond E Ideker; Gregory P Walcott
Journal:  Heart Rhythm       Date:  2008-08-28       Impact factor: 6.343

8.  The nitric oxide synthase inhibitor N(G)-nitro-L-arginine decreases defibrillation-induced free radical generation.

Authors:  Craig B Clark; Yi Zhang; Sean M Martin; L Ray Davies; Linjing Xu; Kevin C Kregel; Francis J Miller; Garry R Buettner; Richard E Kerber
Journal:  Resuscitation       Date:  2004-03       Impact factor: 5.262

9.  Defibrillation in children.

Authors:  Sarah E Haskell; Dianne L Atkins
Journal:  J Emerg Trauma Shock       Date:  2010-07

Review 10.  How good is your defibrillation technique?

Authors:  Daniel M Sado; Charles D Deakin
Journal:  J R Soc Med       Date:  2005-01       Impact factor: 18.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.