Literature DB >> 22447807

Computed tomography myocardial perfusion imaging with 320-row detector computed tomography accurately detects myocardial ischemia in patients with obstructive coronary artery disease.

Richard T George1, Armin Arbab-Zadeh, Julie M Miller, Andrea L Vavere, Frank M Bengel, Albert C Lardo, João A C Lima.   

Abstract

BACKGROUND: Computed tomography coronary angiography (CTA) has been shown to be accurate in detecting anatomic coronary arterial obstruction, but is limited for the detection of myocardial ischemia. The primary aim of this study was to assess the accuracy of 320-row computed tomography perfusion imaging (CTP) to detect atherosclerosis causing myocardial ischemia. METHODS AND
RESULTS: Fifty symptomatic patients with recent single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) underwent a comprehensive cardiac computed tomography (CT) protocol that included 320-CTA, followed by adenosine stress CTP. CTP images were analyzed quantitatively for the presence of subendocardial perfusion deficits. All analyses were blinded to imaging and clinical results. CTA alone was a limited predictor of myocardial ischemia compared with SPECT, with a sensitivity, specificity, positive (PPV) and negative predictive value (NPV) of 56%, 75%, 56%, and 75%, and the area under the receiver operator characteristic curve (AUC) was 0.65 (95% CI, 0.51-0.78, P=0.07). CTP was a better predictor of myocardial ischemia, with a sensitivity, specificity, PPV, and NPV of 72%, 91%, 81%, and 85%, with an AUC of 0.81 (95% CI, 0.68-0.91, P<0.001), and was an excellent predictor of myocardial ischemia on SPECT-MPI in the presence of stenosis (≥50% on CTA), with a sensitivity, specificity, PPV, and NPV of 100%, 81%, 50%, and 100%, with an AUC of 0.92 (95% CI, 0.80-0.97, P<0.001). The radiation dose for the comprehensive cardiac CT protocol and SPECT were 13.8±2.9 and 13.1±1.7; respectively (P=0.15).
CONCLUSIONS: Computed tomography perfusion imaging with rest and adenosine stress 320-row CT is accurate in detecting obstructive atherosclerosis causing myocardial ischemia.

Entities:  

Mesh:

Year:  2012        PMID: 22447807     DOI: 10.1161/CIRCIMAGING.111.969303

Source DB:  PubMed          Journal:  Circ Cardiovasc Imaging        ISSN: 1941-9651            Impact factor:   7.792


  44 in total

1.  Diagnostic accuracy of combined coronary angiography and adenosine stress myocardial perfusion imaging using 320-detector computed tomography: pilot study.

Authors:  Arthur Nasis; Brian S Ko; Michael C Leung; Paul R Antonis; Dee Nandurkar; Dennis T Wong; Leo Kyi; James D Cameron; John M Troupis; Ian T Meredith; Sujith K Seneviratne
Journal:  Eur Radiol       Date:  2013-02-21       Impact factor: 5.315

2.  Evidence for myocardial CT perfusion imaging in the diagnosis of hemodynamically significant coronary artery disease.

Authors:  Zhonghua Sun
Journal:  Cardiovasc Diagn Ther       Date:  2015-02

Review 3.  Myocardial CT perfusion imaging for ischemia detection.

Authors:  Patricia Carrascosa; Carlos Capunay
Journal:  Cardiovasc Diagn Ther       Date:  2017-04

4.  Combined coronary angiography and myocardial perfusion by computed tomography in the identification of flow-limiting stenosis - The CORE320 study: An integrated analysis of CT coronary angiography and myocardial perfusion.

Authors:  Tiago A Magalhães; Satoru Kishi; Richard T George; Armin Arbab-Zadeh; Andrea L Vavere; Christopher Cox; Matthew B Matheson; Julie M Miller; Jeffrey Brinker; Marcelo Di Carli; Frank J Rybicki; Carlos E Rochitte; Melvin E Clouse; João A C Lima
Journal:  J Cardiovasc Comput Tomogr       Date:  2015-03-21

Review 5.  CT imaging of myocardial perfusion: possibilities and perspectives.

Authors:  Alexander Becker; Christoph Becker
Journal:  J Nucl Cardiol       Date:  2013-04       Impact factor: 5.952

Review 6.  Cardiac CT for myocardial ischaemia detection and characterization--comparative analysis.

Authors:  A M Bucher; C N De Cecco; U J Schoepf; R Wang; F G Meinel; S R Binukrishnan; J V Spearman; T J Vogl; B Ruzsics
Journal:  Br J Radiol       Date:  2014-08-19       Impact factor: 3.039

7.  Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography.

Authors:  S Feger; M Rief; E Zimmermann; F Richter; R Roehle; M Dewey; E Schönenberger
Journal:  Eur Radiol       Date:  2015-03-13       Impact factor: 5.315

8.  Detection of ischaemic myocardial lesions with coronary CT angiography and adenosine-stress dynamic perfusion imaging using a 128-slice dual-source CT: diagnostic performance in comparison with cardiac MRI.

Authors:  S M Kim; J-H Choi; S-A Chang; Y H Choe
Journal:  Br J Radiol       Date:  2013-10-04       Impact factor: 3.039

9.  Current status of cardiac CT for the detection of myocardial ischemia.

Authors:  A Schuhbäck; M Marwan; R C Cury; S Achenbach
Journal:  Herz       Date:  2013-06       Impact factor: 1.443

10.  Feasibility of dynamic CT-based adenosine stress myocardial perfusion imaging to detect and differentiate ischemic and infarcted myocardium in an large experimental porcine animal model.

Authors:  Fabian Bamberg; Rabea Hinkel; Roy P Marcus; Elisabeth Baloch; Kristof Hildebrandt; Florian Schwarz; Holger Hetterich; Torleif A Sandner; Christopher L Schlett; Ullrich Ebersberger; Christian Kupatt; Udo Hoffmann; Maximilian F Reiser; Daniel Theisen; Konstantin Nikolaou
Journal:  Int J Cardiovasc Imaging       Date:  2014-02-26       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.