Literature DB >> 22442606

Efficacy of 2-mm locking miniplates in the management of mandibular fractures without maxillomandibular fixation.

Chandan Prabhakar1, Jayaprasad N Shetty, O R Hemavathy, Yadavalli Guruprasad.   

Abstract

BACKGROUND: The management of trauma has evolved greatly over the past many years. Various bone plating systems have been developed to provide stable fixation of mandibular fractures. The introduction of the locking plate/screw system has offered certain advantages over the conventional plating systems. This system does not require intimate adaptation of the miniplates to the underlying bone and has greater stability. This study evaluates the efficacy of locking miniplate/screw system in the treatment of mandibular fractures without maxillomandibular fixation.
MATERIALS AND METHODS: This was a prospective study analyzing 20 patients with undisplaced or minimally displaced mandibular fractures, who reported to Department of Oral and Maxillofacial Surgery, Government Dental College and Research Institute, Bangalore. The selected cases were treated by open reduction and internal fixation using the 2.0 mm locking plate/screw system.
RESULTS: Open reduction and internal fixation with the 2.0 mm locking plate/screw system were achieved in all the 20 cases with satisfactory stability of the fracture fragments. The system was found to be reliable and effective intraoperatively. Only two complications were noted in the study.
CONCLUSION: The locking miniplate system was found to be reliable and effective in management of mandibular fractures without postoperative intermaxillary fixation, however further studies with more sample size is required.

Entities:  

Keywords:  Locking plate/screw system; locking miniplates; mandibular fractures

Year:  2011        PMID: 22442606      PMCID: PMC3304230          DOI: 10.4103/0975-5950.85850

Source DB:  PubMed          Journal:  Natl J Maxillofac Surg        ISSN: 0975-5950


INTRODUCTION

The management of trauma has evolved greatly over the past many years from supportive bandages, splints, circummandibular wiring, extraoral pins, and semi-rigid fixation with transosseous wiring to rigid fixation with compression plates and more lately back to semi-rigid fixation with miniplates.[12] Mandibular fractures are the most common facial injuries treated by the oral and maxillofacial surgeon. Fractures of the mandible occur more frequently than any other fracture of the facial skeleton.[12] Rigid internal fixation of mandibular fractures eliminates the need for intermaxillary fixation and facilitates stable anatomic reduction while reducing the risk of postoperative displacement of the fractured fragments, allowing immediate return to function.[3-5] In the 21st century, the near total abolition of maxillomandibular fixation in the treatment of mandibular fractures is a major step in the evolution of maxillofacial trauma management due to advent of various plating systems.[3-5] Transoral placement of noncompressive miniplate fixation has gained popularity using the principles of Champy and colleagues. Various types of bone-plating systems have been developed to provide stable fixation for mandibular fractures and osteotomies.[67] Currently, modifications in miniplates, like locking plate/screw system, have been developed.[7] The introduction of locking plate/screw miniplate and reconstruction plating systems for the treatment of mandibular fractures and continuity defects has offered certain advantages over other plating systems. A major disadvantage of the conventional bone plate is that it must be perfectly adapted to the underlying bone to prevent alterations in the alignment of the segments and changes in the occlusal relationship.[89] Research continues to focus on the size, shape, number, and biomechanics of plate/screw systems to improve surgical outcomes. In locking plate/screw system, the hole in the plate is engineered to accept screws that lock to it by a second thread under the head of the screw. These plates function as internal fixators achieving stability by locking the screw to the plate.[7-9] A unique advantage of the locking plate/screw system is that it becomes unnecessary for the plate to have intimate contact with the underlying bone, making plate adaptation easier leading to lesser alterations in the alignment of the segments and changes in the occlusal relationship upon screw tightening.[1011] Another theoretical advantage in the locking plate/screw system is that these plates do not disrupt the underlying cortical bone perfusion as much as the conventional plates, which compress the undersurface of the bone plate to the cortical bone.[1011] A third advantage of the locking plate/screw system is that the screws are unlikely to loosen from the bone plate. This means that even if the screw is inserted into the fracture line, loosening of the screw will not occur. The possible advantage to this property of a locking plate/screw system is decreased incidence of inflammatory complications from loosening of hardware.[10-12] The purpose of this study was to review the efficacy of this new locking bone plate or screw system without post surgical maxillomandibular fixation in mandibular fractures.

MATERIALS AND METHODS

This was a prospective study analyzing 20 patients with undisplaced or minimally displaced mandibular fractures, having insignificant medical history. The data were randomly collected from the patients visiting the Department of Oral and Maxillofacial Surgery, Government Dental College and Research Institute, Bangalore. The selected cases were treated by open reduction and internal fixation with 2.0 mm titanium locking miniplates. Inclusion criteria were undisplaced or minimally displaced fractures of the mandible requiring open reduction and internal fixation in any one of the following regions: symphysis, parasymphysis and body or angle region. Exclusion criteria were fractures infected prior to treatment, comminuted fractures or mandibular fractures with associated condylar and coronoid fractures and patients with compromised medical conditions.

Surgical procedure

After the routine clinical and radiological examination protocol, the fracture site was exposed by intraoral approach except in some inaccessible angle fractures, where transbuccal trocar was used with osteosynthesis using locking miniplates without maxillomandibular fixation. In symphysis and parasymphysis region, two miniplates were used, one at inferior and one at superior border; in body and angular region, only one plate was used. The patients were evaluated for the location, type and number of fractures, presence of tooth in fracture line, time elapsed between the presentation of the patient after trauma, complications during surgery, pre and post surgical occlusal relationship, adequacy of reduction on postoperative radiograph and any post surgical complications requiring a secondary surgical intervention. Antibiotics and analgesics were administered for 7 days following surgery. The patients were followed up for a period of 6 weeks initially for every week and a period of 6 months later to assess radiographic evidence of healing [Figures 1–4].
Figure 1

Locking miniplate system

Figure 4

Orthopantomograph showing internal fixation with tooth in the line of fracture extracted

Locking miniplate system Locking miniplates used in this study Orthopantomograph showing left mandibular angle fracture with tooth in the line of fracture Orthopantomograph showing internal fixation with tooth in the line of fracture extracted

The 2.0-mm locking miniplate system

The thickness of the plate was 2 mm, and the lengths of the plates and screws were variable depending on the fracture site and other clinical considerations. The screws were 2 mm longer from the conventional screws wherein the first 2 mm of the screws locks the miniplate. The locking plate/screw system obviously has the advantage of less screw loosening, greater stability, less precision required for plate adaptation, less alteration in postoperative occlusal relationship and more importantly they do not disrupt the underlying cortical bone perfusion. The technique for application of the 2.0-mm locking plates is not different than the application of any other non compression type of miniplate. The only exception is that one should use a drill guide to “center” the drill hole within the center of bone plate to facilitate proper screw locking with the plate [Figures 5 and 6].
Figure 5

Orthopantomograph showing right parasymphysis and left mandibular angle fracture with tooth in the line of fracture

Figure 6

Orthopantomograph showing internal fixation of right parasymphysis and left mandibular angle fracture with tooth in the line of fracture retained

Orthopantomograph showing right parasymphysis and left mandibular angle fracture with tooth in the line of fracture Orthopantomograph showing internal fixation of right parasymphysis and left mandibular angle fracture with tooth in the line of fracture retained

RESULTS

Among the study population, the majority of cases were in the age group of 21-30 years (65%) with a mean age of 28.8 years. There were 19 (95%) male and 1 (5%) female patient of Asian origin, with road traffic accident (RTA) being the most common etiological cause 11 (55%), followed by assault 5 (25%), and work-related or self-fall 4 (20%) [Table 1].
Table 1

Cause of injury

Cause of injury Fracture distribution consisted of 14 parasymphysis (43.75%), 2 symphysis (6.25%), 8 body (25%) and 8 angle (25%) fractures, with a total of 32 fracture sites in the 20 cases selected, with 15 fractures distributed on both left and right sides of the mandible [Graph 1]. There were 13 undisplaced and 7 minimally displaced fractures observed. Teeth in fracture line were retained in 15 (75%) cases and extracted in 5 (25%) cases. Teeth were extracted only when there was an absolute indication, with the most common reason being fractured teeth.
Graph 1

Distribution of site of fracture

Distribution of site of fracture The fractures were treated ranging from 1 to 5 days with a mean of 1.8 days from the time of injury. The fractures were approached intraorally in 15 (75%) cases, a combination of both intraoral and extraoral approach was used when extraoral lacerations were present in 4 (20%) of the cases and 1 (5%) fracture was approached through an external laceration. All the patients were followed up for postoperative complications initially on a weekly basis for 6 weeks and later monthly till 6 months. A minor complication (3.125%) of wound dehiscence was noted which was treated with wound irrigation and local measures. There was one major complication with infection (3.125%) at fracture site, requiring incision and drainage and subsequent miniplate removal after 5 weeks of fracture treatment. This patient was placed on an 8-day period of Maxillomandibular fixation. The infection resolved after hardware removal and the fracture showed delayed healing during the follow-up period. The other fracture sites healed without any complications. Primary bone healing was noted in the 93.75% of fracture sites with overall postoperative complications of 6.25% in the study [Graph 2].
Graph 2

Overall complications

Overall complications

DISCUSSION

The objective in the treatment of mandibular fracture is to re-establish normal occlusion and masticatory function. Conservative treatment to achieve this is performed by immobilizing the mandible for the healing period by intermaxillary fixation which is achieved by dental wiring, arch bars, cap splints, and gunning splints.[1112] Operative treatment of mandibular fractures involves intraoral or extraoral opening of the fracture site and direct osteosynthesis with transosseous wires (Schwenzes 1982), lag screws (Niederdellmann 1982), or bone plates (Schilli 1975, Spiessel 1976).[13-15] A number of fixation methods have been advocated for the treatment of mandibular fractures. A new type of plating system is “the locking plate/screw system”, which was initially developed by Raveh et al.[16] In the mid 1980s, the principles of external fixation device were incorporated into a bone plate. These plates achieve stability by locking the screw into the plate and have been shown to enhance fixation stability. A unique advantage to the locking plate/screw system is that it becomes unnecessary for the plate to have intimate contact with the underlying bone, making plate adaptation easier leading to lesser alterations in the alignment of the segments and changes in the occlusal relationship upon screw tightening.[1718] Another theoretical advantage in the locking plate/screw system is that these plates do not disrupt the underlying cortical bone perfusion as much as the conventional plates which compress the undersurface of the bone plate to the cortical bone (Edward Ellis III and John Graham 2002).[1920] A third advantage of the locking plate/screw system is that the screws are unlikely to loosen from the plate. This means that even if the screw is inserted into the fracture line, loosening of the screw will not occur. The possible advantage to this property of the locking plate/screw system is decreased incidence of inflammatory complications from loosening of hardware (Reza Bolourian 2002).[21] It is also proposed that this system provides greater stability that provided by the standard conventional miniplate (Edward Ellis III and John Graham 2002).[22] It is observed that the degree of plate adaptation affected the mechanical behavior of nonlocking plates but did not affect the locking plate/screw system. The only exception is that one should use a drill guide to "center" the drill hole within the center of bone plate to facilitate proper screw locking to the plate (Brain Alpert, Rolf Gutwald, and Rainer Schmelzeisen 2003).[2324] The screws, plate and bone form a solid framework with higher stability than the traditional miniplate system. The locking plate/screw system has demonstrated higher stability across a fracture/osteotomy gap compared with the conventional nonlocking 2.0 mm miniplate in in vitro studies.[25] Our study reviews the efficacy of 2.0-mm locking plate/screw system in 20 patients requiring open reduction and internal fixation without maxillomandibular fixation. The patients were evaluated for the location, type and number of fractures; presence of tooth in line, time elapsed between the presentation of the patient after trauma, pre and post surgical occlusal relationship, adequacy of reduction on postoperative radiograph, and any post surgical complications requiring a secondary surgical intervention. In this study, 32 fractures were observed in the 20 patients selected. Open reduction and internal fixation was carried out in standard operating protocol using either an intraoral or an extraoral approach. The system was found to be reliable and effective treatment modality of mandibular fractures. Our observations do correlate with those of the study conducted by Ayman Chritah, Stewart K Lazow, and Julius R Berger (2005).[2627] Postoperative complications were noted in two patients. One developed an intraoral wound dehiscence which was treated with antibiotics and local measures. There was one major complication (3.125%) with infection at fracture site requiring incision and drainage and subsequent miniplate removal after 5 weeks of fracture treatment. Primary bone healing was noted in 93.75% of fracture sites with an overall postoperative complication of 6.25% in the study. Our study observations do correlate with those of the study conducted by Edward Ellis III and John Graham (2002).[28] In this study, a sincere attempt was made to clinically evaluate the efficacy of 2.0 mm locking plate/screw system in treatment of mandibular fractures without maxillomandibular fixation and the results of this study are in accordance with the study conducted bydifferent authors.
  27 in total

1.  Principle and stability of locking plates.

Authors:  Ralf Gutwald; Brian Alpert; Rainer Schmelzeisen
Journal:  Keio J Med       Date:  2003-03

Review 2.  Development of the Locking Compression Plate.

Authors:  Robert Frigg
Journal:  Injury       Date:  2003-11       Impact factor: 2.586

3.  Mandibular fractures: Historical perspective.

Authors:  R Mukerji; G Mukerji; M McGurk
Journal:  Br J Oral Maxillofac Surg       Date:  2005-08-19       Impact factor: 1.651

4.  Histologic study of the bone adjacent to titanium bone screws used for mandibular fracture treatment.

Authors:  H Hirai; A Okumura; M Goto; T Katsuki
Journal:  J Oral Maxillofac Surg       Date:  2001-05       Impact factor: 1.895

5.  Transoral 2.0-mm locking miniplate fixation of mandibular fractures plus 1 week of maxillomandibular fixation: a prospective study.

Authors:  Ayman Chritah; Stewart K Lazow; Julius R Berger
Journal:  J Oral Maxillofac Surg       Date:  2005-12       Impact factor: 1.895

6.  Rigid internal fixation of mandibular fractures--an analysis of 45 patients treated according to the ASIF method.

Authors:  C Lindqvist; R Kontio; A Pihakari; S Santavirta
Journal:  Int J Oral Maxillofac Surg       Date:  1986-12       Impact factor: 2.789

7.  Fixation of mandibular fractures: a comparative analysis of rigid internal fixation and standard fixation techniques.

Authors:  T B Dodson; D H Perrott; L B Kaban; N C Gordon
Journal:  J Oral Maxillofac Surg       Date:  1990-04       Impact factor: 1.895

8.  Study of mandibular fracture repair using quantitative radiodensitometry: a comparison between maxillomandibular and rigid internal fixation.

Authors:  P M Villarreal; L M Junquera; A Martínez; L García-Consuegra
Journal:  J Oral Maxillofac Surg       Date:  2000-07       Impact factor: 1.895

9.  Analysis of complications in fractures of the mandibular angle--a study with finite element computation and evaluation of data of 277 patients.

Authors:  Kay-Uwe Feller; Matthias Schneider; Matthias Hlawitschka; Günter Pfeifer; Günter Lauer; Uwe Eckelt
Journal:  J Craniomaxillofac Surg       Date:  2003-10       Impact factor: 2.078

10.  Supplemental maxillomandibular fixation with miniplate osteosynthesis.

Authors:  J Valentino; L J Marentette
Journal:  Otolaryngol Head Neck Surg       Date:  1995-02       Impact factor: 5.591

View more
  2 in total

1.  Comparison of 2 mm single locking miniplates versus 2 mm two non-locking miniplates in symphysis and parasymphysis fracture of mandible.

Authors:  Arpit Vashistha; Manpreet Singh; Manoj Chaudhary; Nimish Agarwal; Gagandeep Kaur
Journal:  J Oral Biol Craniofac Res       Date:  2016-02-01

2.  Efficacy of Locking Miniplates in Managing Mandibular Fractures without Intermaxillary Fixation.

Authors:  Sweta Sweta; Nikhil Raj; Manisha Malik; Ashish Kumar; Mukesh Kumar; K A Ahamed Irfan; Priyadarshini Rangari
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.