Literature DB >> 15510361

A prospective randomized clinical trial comparing 2.0-mm locking plates to 2.0-mm standard plates in treatment of mandible fractures.

Chad P Collins1, Galia Pirinjian-Leonard, Andrew Tolas, Rafael Alcalde.   

Abstract

PURPOSE: The purpose of this study was to compare standard 2.0-mm monocortical plates to 2.0-mm locking plates in the treatment of mandible fractures. PATIENTS AND METHODS: A prospective randomized clinical trial was conducted at Harborview Medical Center in Seattle, WA, from January 1, 2002, to February 1, 2003, to compare 2.0-mm locking plates to 2.0-mm standard plates in treating consecutive mandible fractures. Patients were randomly assigned to receive locking 2.0-mm plates (group A) or nonlocking 2.0-mm plates (group B). Complications were divided into major and minor categories. Each complication was analyzed according to which plate was used and where the fracture occurred. The number of days from injury to operation, average age, gender, American Society of Anesthesiologists (ASA) classification,compliance, and social habits were all reviewed.
RESULTS: Ninety patients with 122 fractures met the inclusion criteria. Sixty-four fracture sites were treated with locking plates and 58 with standard plates. A total of 6 complications occurred: 2 occurred at the angle, 3 at the parasymphysis, and 1 at the body. Three complications occurred in the locking group and 3 in the standard group with complication rates equaling 4.6% and 5.2%, respectively. When comparing the overall complication rates according to plates used, the Fisher exact test showed no statistically significant difference between the locking and standard plates (P = .90). The 95% confidence interval for the odds ratio is from 0.1 to 7.
CONCLUSION: Mandible fractures treated with 2.0-mm locking plates and standard 2.0-mm plates present similar short-term complication rates.

Entities:  

Mesh:

Year:  2004        PMID: 15510361     DOI: 10.1016/j.joms.2004.04.020

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  25 in total

1.  Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates and 3-D Locking Plates.

Authors:  Manoj Goyal; Karan Marya; Sonia Chawla; Richa Pandey
Journal:  J Maxillofac Oral Surg       Date:  2011-03-25

2.  Comparison of 2 mm single locking miniplates versus 2 mm two non-locking miniplates in symphysis and parasymphysis fracture of mandible.

Authors:  Arpit Vashistha; Manpreet Singh; Manoj Chaudhary; Nimish Agarwal; Gagandeep Kaur
Journal:  J Oral Biol Craniofac Res       Date:  2016-02-01

3.  Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates & 3-D Locking Plates.

Authors:  Manoj Goyal; Karan Marya; Sonia Chawla; Richa Pandey
Journal:  J Maxillofac Oral Surg       Date:  2011-05-22

4.  Pearls of mandibular trauma management.

Authors:  John C Koshy; Evan M Feldman; Chuma J Chike-Obi; Jamal M Bullocks
Journal:  Semin Plast Surg       Date:  2010-11       Impact factor: 2.314

5.  Comparison of 3D plate and locking plate in treatment of mandibular fracture-a clinical study.

Authors:  Sakshi Aggarwal; Manpreet Singh; Palash Modi; Esha Walia; Rachit Aggarwal
Journal:  Oral Maxillofac Surg       Date:  2017-08-07

6.  Study of Efficacy and the Comparison Between 2.0 mm Locking Plating System and 2.0 mm Standard Plating System in Mandibular Fractures.

Authors:  B Pavan Kumar; K A Jeevan Kumar; V Venkatesh; A P Mohan; K Ramesh; K Mallikarjun
Journal:  J Maxillofac Oral Surg       Date:  2014-11-05

7.  Pattern and treatment of mandible body fracture.

Authors:  Sergio Olate; Adriano Freitas de Assis; Leandro Pozzer; Lucas Cavalieri-Pereira; Luciana Asprino; Marcio de Moraes
Journal:  Int J Burns Trauma       Date:  2013-07-08

8.  Evaluation of 2.0-mm Titanium Three-Dimensional Curved Angle Strut Plate in the Fixation of Mandibular Angle Fractures-A Prospective Clinical and Radiological Analysis.

Authors:  Gaurav Chhabaria; Rajshekhar Halli; Sanjay Chandan; Samir Joshi; Sneha Setiya; Anand Shah
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-02-20

9.  Standard 3D Titanium Miniplate Versus Locking 3D Miniplate in Fracture of Mandible: A Prospective Comparative Study.

Authors:  Arjun Singh; K V Arunkumar
Journal:  J Maxillofac Oral Surg       Date:  2015-07-29

10.  The Use of 2.4-mm Locking Plate System in Treating Comminuted Mandibular Fracture by Firearm.

Authors:  Cassiano Costa Silva Pereira; Pâmela Letícia Dos Santos; Ellen Cristina Gaetti Jardim; Idelmo Rangel Garcia Júnior; Elio Hitoshi Shinohara; Marcelo Marotta Araujo
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2012-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.