Literature DB >> 22430524

Catastrophic failure after open reduction internal fixation of femoral neck fractures with a novel locking plate implant.

Marschall B Berkes1, Milton T M Little, Lionel E Lazaro, Rachel M Cymerman, David L Helfet, Dean G Lorich.   

Abstract

OBJECTIVES: To determine if the use of a novel proximal femoral locking plate could reduce the incidence of femoral neck shortening and improve clinical outcomes after open reduction internal fixation (ORIF) for femoral neck fractures as compared with historical controls.
DESIGN: Single surgeon, retrospective case-control study.
SETTING: Academic level I trauma center. PATIENTS/PARTICIPANTS: Twenty-one femoral neck fractures treated with the posterolateral femoral locking plate (Synthes, Inc, Paoli, PA) were eligible for inclusion. Eighteen met inclusion/exclusion criteria with a mean follow-up of 16 months. INTERVENTION: ORIF of femoral neck fracture with the posterolateral femoral locking plate. This consists of a side plate with multiple locking screws directed into the femoral head at converging/diverging angles and a single shaft screw. Intraoperative compression was achieved with partially threaded screws before locking screw insertion. MAIN OUTCOME MEASUREMENTS: Maintenance of reduction was assessed by comparing immediate postoperative and final follow-up radiographs. Clinical outcome was assessed with Harris Hip Scores after 1 year. Complications and secondary operations were noted.
RESULTS: Seven (36.8%) of 18 patients experienced catastrophic failure. Five of these patients required total hip replacement, whereas the remaining 2 died before further treatment. The remaining 11 patients (61.1%) achieved bony union; the average displacement of the center of the head did not differ when compared with historical controls (0.78 mm inferiorly, 1.62 mm medially, and 2.4 degrees of increased varus vs. 0.86 mm, 1.23 mm, and 0.6 degree). Complications in this group include 1 instance of screw fracture, 2 total hip replacements, and a peri-implant subtrochanteric femur fracture. The average patient age and proportion of displaced fractures did not differ between the historical control and experimental groups. Fracture displacement was strongly associated with catastrophic failure in the experimental group only. Average Harris Hip Scores was significantly worse compared with that of historical controls (67.9 vs. 84.7, P = 0.05).
CONCLUSIONS: ORIF of femoral neck fractures using a locking plate construct yielded unacceptably poor outcomes in this patient population. We hypothesize that the stiffness of this construct prevents any fracture site micromotion, placing the mechanical burden on the implant, which can result in failure at the bone-screw interface or fatigue failure of the implant itself.

Entities:  

Mesh:

Year:  2012        PMID: 22430524     DOI: 10.1097/BOT.0b013e31823b4cd1

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  16 in total

1.  Subtrochanteric Fractures: Comparison of Proximal Femur Locking Plate and Intramedullary Locking Nail Fixation Outcome.

Authors:  Ahmadreza Mirbolook; Babak Siavashi; Adel Ebrahimpour Jafarinezhad; Sina Khajeh Jahromi; Maral Farahmand; Melina Roohi Rad; Mohammad Amin Kahe
Journal:  Indian J Surg       Date:  2013-11-16       Impact factor: 0.656

2.  The use of the 95-degree-angled blade plate in femoral nonunion surgery.

Authors:  Louis F Amorosa; Prem R Jayaram; David S Wellman; Dean G Lorich; David L Helfet
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-07-26

3.  Novel Treatment Options for the Surgical Management of Young Femoral Neck Fractures.

Authors:  Ashley E Levack; Elizabeth B Gausden; Aleksey Dvorzhinskiy; Dean G Lorich; David L Helfet
Journal:  J Orthop Trauma       Date:  2019-01       Impact factor: 2.512

4.  [Effectiveness analysis of medial buttress plate augmented hollow lag screws fixation in combination with sartorius pedicled iliac flap for the treatment of femoral neck fractures in young adults].

Authors:  Hai Wang; Junjian Ye; Chunyong Chen; Gui Wu; Yaoqing Chen; Yun Xie
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-02-15

5.  Factors Associated with Femoral Neck Shortening After Closed or Open Reduction and Screw Fixation.

Authors:  Abdulkadir Polat; Abdulhamit Misir; Mehmet Ozbey Buyukkuscu; Seckin Basilgan; Hakan Basar
Journal:  Indian J Orthop       Date:  2021-08-14       Impact factor: 1.033

6.  [Joint-preserving treatment of medial femoral neck fractures with an angular stable implant].

Authors:  M Saß; T Mittlmeier
Journal:  Oper Orthop Traumatol       Date:  2016-05-03       Impact factor: 1.154

7.  The Telescoping Hip Plate for Treatment of Femoral Neck Fracture: Design Rationale, Surgical Technique and Early Results.

Authors:  Michael Willey; Matthew L Welsh; Travis S Roth; Kenneth J Koval; James V Nepola
Journal:  Iowa Orthop J       Date:  2018

8.  Increased Fracture Collapse after Intertrochanteric Fractures Treated by the Dynamic Hip Screw Adversely Affects Walking Ability but Not Survival.

Authors:  Christian Fang; Paata Gudushauri; Tak-Man Wong; Tak-Wing Lau; Terence Pun; Frankie Leung
Journal:  Biomed Res Int       Date:  2016-02-03       Impact factor: 3.411

Review 9.  Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate.

Authors:  Bjarke Viberg; Katrine M V Rasmussen; Søren Overgaard; Cecilia Rogmark
Journal:  Acta Orthop       Date:  2017-03-13       Impact factor: 3.717

10.  Comparison of early complications between the use of a cannulated screw locking plate and multiple cancellous screws in the treatment of displaced intracapsular hip fractures in young adults: a randomized controlled clinical trial.

Authors:  Zhiqiang Wang; Yi Yin; Qingshan Li; Guanjun Sun; Xu Peng; Hua Yin; Yongjie Ye
Journal:  J Orthop Surg Res       Date:  2018-08-13       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.