Literature DB >> 22416291

Measurement of knee joint gaps without bone resection: "physiologic" extension and flexion gaps in total knee arthroplasty are asymmetric and unequal and anterior and posterior cruciate ligament resections produce different gap changes.

Andrej Maria Nowakowski1, Martin Majewski, Magdalena Müller-Gerbl, Victor Valderrabano.   

Abstract

General agreement is that flexion and extension gaps should be equal and symmetrical in total knee arthroplasty (TKA) procedures. However, comparisons using a standard TKA approach to normal knee joints that have not undergone bone resection are currently unavailable. Since bony preparation can influence capsule and ligament tension, our purpose was to perform measurements without this influence. Ten normal cadaveric knees were assessed using a standard medial parapatellar TKA approach with patellar subluxation. Gap measurements were carried out twice each alternating 100 and 200 N per compartment using a prototypical force-determining ligament balancer without the need for bony resection. Initial measurements were performed in extension, followed by 908 of flexion. The ACL was then resected, and finally the PCL was resected, and measurements were carried out in an analogous fashion. In general, the lateral compartment could be stretched further than the medial compartment, and the corresponding flexion gap values were significantly larger. ACL resection predominantly increased extension gaps, while PCL resection increased flexion gaps. Distraction force of 100 N per compartment appeared adequate; increasing to 200 N did not improve the results.

Entities:  

Mesh:

Year:  2012        PMID: 22416291     DOI: 10.1002/jor.21564

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  15 in total

1.  Patient-related factors influence stiffness of the soft tissue complex during intraoperative gap balancing in cruciate-retaining total knee arthroplasty.

Authors:  P J C Heesterbeek; N Haffner; A B Wymenga; J Stifter; P Ritschl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-15       Impact factor: 4.342

2.  Posterior reference guides do not always maintain the size of posterior femoral condyles in TKA.

Authors:  Yukihide Minoda; Shigekazu Mizokawa; Yoichi Ohta; Mitsuhiko Ikebuchi; Maki Itokazu; Kazumasa Yamamura; Suguru Nakamura; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-21       Impact factor: 4.342

3.  Proven accuracy for a new dynamic gap measurement in navigated TKA.

Authors:  Volkmar Mehliß; Marco Strauch Leira; Agustín Serrano Olaizola; Wolfgang Scior; Heiko Graichen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-05-22       Impact factor: 4.342

4.  How precise is computer-navigated gap assessment in TKA?

Authors:  James B Stiehl; David A Heck
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

5.  Influence of tibial slope on extension and flexion gaps in total knee arthroplasty: increasing the tibial slope affects both gaps.

Authors:  Andrej Maria Nowakowski; Marcus Kamphausen; Geert Pagenstert; Victor Valderrabano; Magdalena Müller-Gerbl
Journal:  Int Orthop       Date:  2014-05-25       Impact factor: 3.075

6.  Shear wave speeds track axial stress in porcine collateral ligaments.

Authors:  Jonathon L Blank; Darryl G Thelen; Joshua D Roth
Journal:  J Mech Behav Biomed Mater       Date:  2020-02-18

7.  A single type of varus knee does not exist: morphotyping and gap analysis in varus OA.

Authors:  Heiko Graichen; Kreangsak Lekkreusuwan; Kim Eller; Thomas Grau; Michael T Hirschmann; Wolfgang Scior
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-08-19       Impact factor: 4.114

8.  Low tibial baseplate migration 1 year after unrestricted kinematically aligned total knee arthroplasty using a medial conforming implant design.

Authors:  Abigail E Niesen; Anna L Garverick; Stephen M Howell; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-10-06       Impact factor: 4.114

Review 9.  [Kinematic alignment-management of deformities and flexion contractures].

Authors:  M Malavolta; K Kley
Journal:  Orthopade       Date:  2021-03       Impact factor: 1.087

10.  Varus-valgus stability at 90° flexion correlates with the stability at midflexion range more widely than that at 0° extension in posterior-stabilized total knee arthroplasty.

Authors:  Kazunori Hino; Tatsuhiko Kutsuna; Kunihiko Watamori; Hiroshi Kiyomatsu; Yasumitsu Ishimaru; Jun Takeba; Seiji Watanabe; Yoshitaka Shiraishi; Hiromasa Miura
Journal:  Arch Orthop Trauma Surg       Date:  2017-08-28       Impact factor: 3.067

View more