Literature DB >> 22414638

Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner.

Hyun Suk Yoon1, Guen Bae Ko, Sun Il Kwon, Chan Mi Lee, Mikiko Ito, In Chan Song, Dong Soo Lee, Seong Jong Hong, Jae Sung Lee.   

Abstract

UNLABELLED: The most investigated semiconductor photosensor for MRI-compatible PET detectors is the avalanche photodiode (APD). However, the silicon photomultiplier (SiPM), also called the Geiger-mode APD, is gaining attention in the development of the next generation of PET/MRI systems because the SiPM has much better performance than the APD. We have developed an MRI-compatible PET system based on multichannel SiPM arrays to allow simultaneous PET/MRI.
METHODS: The SiPM PET scanner consists of 12 detector modules with a ring diameter of 13.6 cm and an axial extent of 3.2 cm. In each detector module, 4 multichannel SiPM arrays (with 4 × 4 channels arranged in a 2 × 2 array to yield 8 × 8 channels) were coupled with 20 × 18 Lu(1.9)Gd(0.1)SiO(5):Ce crystals (each crystal is 1.5 × 1.5 × 7 mm) and mounted on a charge division network for multiplexing 64 signals into 4 position signals. Each detector module was enclosed in a shielding box to reduce interference between the PET and MRI scanners, and the temperature inside the box was monitored for correction of the temperature-dependent gain variation of the SiPM. The PET detector signal was routed to the outside of the MRI room and processed with a field programmable gate array-based data acquisition system. MRI compatibility tests and simultaneous PET/MRI acquisitions were performed inside a 3-T clinical MRI system with 4-cm loop receiver coils that were built into the SiPM PET scanner. Interference between the imaging systems was investigated, and phantom and mouse experiments were performed.
RESULTS: No radiofrequency interference on the PET signal or degradation in the energy spectrum and flood map was shown during simultaneous PET/MRI. The quality of the MRI scans acquired with and without the operating PET showed only slight degradation. The results of phantom and mouse experiments confirmed the feasibility of this system for simultaneous PET/MRI.
CONCLUSION: Simultaneous PET/MRI was possible with a multichannel SiPM-based PET scanner, with no radiofrequency interference on PET signals or images and only slight degradation of the MRI scans.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22414638     DOI: 10.2967/jnumed.111.097501

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  26 in total

Review 1.  PET/MRI of central nervous system: current status and future perspective.

Authors:  Zhen Lu Yang; Long Jiang Zhang
Journal:  Eur Radiol       Date:  2016-01-15       Impact factor: 5.315

Review 2.  Recent advances in cardiac SPECT instrumentation and system design.

Authors:  Mark F Smith
Journal:  Curr Cardiol Rep       Date:  2013-08       Impact factor: 2.931

Review 3.  PET/MRI: current state of the art and future potential for cardiovascular applications.

Authors:  Nebiyu Adenaw; Michael Salerno
Journal:  J Nucl Cardiol       Date:  2013-12       Impact factor: 5.952

4.  Development of 1.45-mm resolution four-layer DOI-PET detector for simultaneous measurement in 3T MRI.

Authors:  Fumihiko Nishikido; Atsushi Tachibana; Takayuki Obata; Naoko Inadama; Eiji Yoshida; Mikio Suga; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2014-10-28

5.  Evaluation of Matrix9 silicon photomultiplier array for small-animal PET.

Authors:  Junwei Du; Jeffrey P Schmall; Yongfeng Yang; Kun Di; Emilie Roncali; Gregory S Mitchell; Steve Buckley; Carl Jackson; Simon R Cherry
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

Review 6.  Quantitative Rodent Brain Receptor Imaging.

Authors:  Kristina Herfert; Julia G Mannheim; Laura Kuebler; Sabina Marciano; Mario Amend; Christoph Parl; Hanna Napieczynska; Florian M Maier; Salvador Castaneda Vega; Bernd J Pichler
Journal:  Mol Imaging Biol       Date:  2020-04       Impact factor: 3.488

7.  Small animal, positron emission tomography-magnetic resonance imaging system based on a clinical magnetic resonance imaging scanner: evaluation of basic imaging performance.

Authors:  Raymond R Raylman; Patrick Ledden; Alexander V Stolin; Bob Hou; Ganghadar Jaliparthi; Peter F Martone
Journal:  J Med Imaging (Bellingham)       Date:  2018-09-08

8.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

9.  Design, evaluation and initial imaging results of a PET insert based on strip-line readout for simultaneous PET/MRI.

Authors:  H Kim; Y Hua; H-T Chen; H-M Tsai; C-T Chen; G Karczmar; X Fan; D Xi; Q Xie; C-Y Chou; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2020-02-05       Impact factor: 1.455

Review 10.  Current Status of Hybrid PET/MRI in Oncologic Imaging.

Authors:  Andrew B Rosenkrantz; Kent Friedman; Hersh Chandarana; Amy Melsaether; Linda Moy; Yu-Shin Ding; Komal Jhaveri; Luis Beltran; Rajan Jain
Journal:  AJR Am J Roentgenol       Date:  2015-10-22       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.