Literature DB >> 22413894

N95 filtering facepiece respirator deadspace temperature and humidity.

Raymond J Roberge1, Jung-Hyun Kim, Stacey Benson.   

Abstract

The objective of this study was to determine the levels of heat and humidity that develop within the deadspace of N95 filtering facepiece respirators (N95 FFR). Seventeen subjects wore two models each of N95 FFR and N95 FFR with an exhalation valve (N95 FFR/EV) while exercising on a treadmill at a low-moderate work rate for 1 and 2 hr in a temperate ambient environment. FFR deadspace temperature and relative humidity were monitored by a wireless sensor housed within the FFR. Each FFR was weighed pre- and post-testing to determine moisture retention. After 1 hr, FFR deadspace temperature and humidity were markedly elevated above ambient levels, and the FFR deadspace mean apparent heat index was 54°C. N95 FFR/EV use resulted in significantly lower deadspace temperatures than N95 FFR (p = 0.01), but FFR deadspace humidity levels were not significantly different (p = 0.32). Compared with the first hour of use, no significant increase in FFR deadspace heat and humidity occurred over the second hour. FFR mean moisture retention was < 0.3 grams over 2 hr. N95 FFR/EV offer a significant advantage in deadspace heat dissipation over N95 FFR at a low-moderate work rate over 1 hr of continuous use but offered no additional benefit in humidity amelioration. Moisture retention in N95 FFR and N95 FFR/EV is minimal after 2 hr of use. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: a file containing N95 filtering facepiece respirator deadspace mean RH and temperature recordings for 17 subjects treadmill exercising at 5.6 Km/H over 1 hour.].

Entities:  

Mesh:

Year:  2012        PMID: 22413894     DOI: 10.1080/15459624.2012.660428

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  17 in total

1.  N95 respirator use during advanced pregnancy.

Authors:  Raymond J Roberge; Jung-Hyun Kim; Jeffrey B Powell
Journal:  Am J Infect Control       Date:  2014-10       Impact factor: 2.918

2.  Comfort and exertion while using filtering facepiece respirators with exhalation valve and an active venting system among male military personnel.

Authors:  Melvin Seng; Liang En Wee; Xiahong Zhao; Alex R Cook; Sin Eng Chia; Vernon J Lee
Journal:  Singapore Med J       Date:  2017-07-06       Impact factor: 1.858

3.  A Modified Method for Measuring Pressure Drop in Non-medical Face Masks with Automated Data Acquisition and Analysis.

Authors:  Alexander Herman; Daniel Porter; Dana Rottach; Suvajyoti Guha
Journal:  J Int Soc Respir Prot       Date:  2021-12-31

Review 4.  Selecting models for a respiratory protection program: what can we learn from the scientific literature?

Authors:  Ronald E Shaffer; Larry L Janssen
Journal:  Am J Infect Control       Date:  2014-12-10       Impact factor: 2.918

Review 5.  Review of the Breathability and Filtration Efficiency of Common Household Materials for Face Masks.

Authors:  Laura H Kwong; Rob Wilson; Shailabh Kumar; Yoshika Susan Crider; Yasmin Reyes Sanchez; David Rempel; Ajay Pillarisetti
Journal:  ACS Nano       Date:  2021-04-06       Impact factor: 15.881

6.  Reduction of Carbon Dioxide in Filtering Facepiece Respirators with an Active-Venting System: A Computational Study.

Authors:  Erik Birgersson; Ee Ho Tang; Wei Liang Jerome Lee; Kwok Jiang Sak
Journal:  PLoS One       Date:  2015-06-26       Impact factor: 3.240

7.  Impact of low filter resistances on subjective and physiological responses to filtering facepiece respirators.

Authors:  Raymond J Roberge; Jung-Hyun Kim; Jeffrey B Powell; Ronald E Shaffer; Caroline M Ylitalo; John M Sebastian
Journal:  PLoS One       Date:  2013-12-27       Impact factor: 3.240

8.  Comparison of fit factors among healthcare providers working in the Emergency Department Center before and after training with three types of N95 and higher filter respirators.

Authors:  Hongjung Kim; Juncheol Lee; Sanghyun Lee; Jaehoon Oh; Boseung Kang; Tae Ho Lim; Hyunggoo Kang
Journal:  Medicine (Baltimore)       Date:  2019-02       Impact factor: 1.817

9.  An Improved FFR Design with a Ventilation Fan: CFD Simulation and Validation.

Authors:  Xiaotie Zhang; Hui Li; Shengnan Shen; Yu Rao; Feng Chen
Journal:  PLoS One       Date:  2016-07-25       Impact factor: 3.240

10.  Considerations for recommending extended use and limited reuse of filtering facepiece respirators in health care settings.

Authors:  Edward M Fisher; Ronald E Shaffer
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.