Literature DB >> 22411124

Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis.

Richard Castillo1, Edward Castillo, Matthew McCurdy, Daniel R Gomez, Alec M Block, Derek Bergsma, Sarah Joy, Thomas Guerrero.   

Abstract

To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R² = 0.99). Respective values for the average DSC, NDSC(1 mm) and NDSC(2 mm) for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between clinically acquired SPECT perfusion and specific ventilation from 4D CT. Results suggest high correlation between methods within the sub-population of lung cancer patients with malignant airway stenosis.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22411124     DOI: 10.1088/0031-9155/57/7/1855

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  23 in total

1.  4D CT lung ventilation images are affected by the 4D CT sorting method.

Authors:  Tokihiro Yamamoto; Sven Kabus; Cristian Lorenz; Eric Johnston; Peter G Maxim; Maximilian Diehn; Neville Eclov; Cristian Barquero; Billy W Loo; Paul J Keall
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

2.  Regional Lung Function Profiles of Stage I and III Lung Cancer Patients: An Evaluation for Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Leah Schubert; Quentin Diot; Timothy Waxweiller; Phillip Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Chad Rusthoven; Laurie Gaspar; Brian Kavanagh; Moyed Miften
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-07-15       Impact factor: 7.038

3.  Clinical validation of 4-dimensional computed tomography ventilation with pulmonary function test data.

Authors:  Douglas Brennan; Leah Schubert; Quentin Diot; Richard Castillo; Edward Castillo; Thomas Guerrero; Mary K Martel; Derek Linderman; Laurie E Gaspar; Moyed Miften; Brian D Kavanagh; Yevgeniy Vinogradskiy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-25       Impact factor: 7.038

4.  Technical Note: Deriving ventilation imaging from 4DCT by deep convolutional neural network.

Authors:  Yuncheng Zhong; Yevgeniy Vinogradskiy; Liyuan Chen; Nick Myziuk; Richard Castillo; Edward Castillo; Thomas Guerrero; Steve Jiang; Jing Wang
Journal:  Med Phys       Date:  2019-03-12       Impact factor: 4.071

5.  Reproducibility of four-dimensional computed tomography-based lung ventilation imaging.

Authors:  Tokihiro Yamamoto; Sven Kabus; Jens von Berg; Cristian Lorenz; Melody P Chung; Julian C Hong; Billy W Loo; Paul J Keall
Journal:  Acad Radiol       Date:  2012-09-10       Impact factor: 3.173

6.  Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.

Authors:  Kaifang Du; Joseph M Reinhardt; Gary E Christensen; Kai Ding; John E Bayouth
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

7.  Interim Analysis of a Two-Institution, Prospective Clinical Trial of 4DCT-Ventilation-based Functional Avoidance Radiation Therapy.

Authors:  Yevgeniy Vinogradskiy; Chad G Rusthoven; Leah Schubert; Bernard Jones; Austin Faught; Richard Castillo; Edward Castillo; Laurie E Gaspar; Jennifer Kwak; Timothy Waxweiler; Michele Dougherty; Dexiang Gao; Craig Stevens; Moyed Miften; Brian Kavanagh; Thomas Guerrero; Inga Grills
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-10-18       Impact factor: 7.038

8.  Comparison of 4-dimensional computed tomography ventilation with nuclear medicine ventilation-perfusion imaging: a clinical validation study.

Authors:  Yevgeniy Vinogradskiy; Phillip J Koo; Richard Castillo; Edward Castillo; Thomas Guerrero; Laurie E Gaspar; Moyed Miften; Brian D Kavanagh
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-05-01       Impact factor: 7.038

9.  Changes in Regional Ventilation During Treatment and Dosimetric Advantages of CT Ventilation Image Guided Radiation Therapy for Locally Advanced Lung Cancer.

Authors:  Tokihiro Yamamoto; Sven Kabus; Matthieu Bal; Karl Bzdusek; Paul J Keall; Cari Wright; Stanley H Benedict; Megan E Daly
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-05-04       Impact factor: 7.038

10.  A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive.

Authors:  Richard Castillo; Edward Castillo; David Fuentes; Moiz Ahmad; Abbie M Wood; Michelle S Ludwig; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2013-04-10       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.