| Literature DB >> 22399846 |
Robert P Lehmann1, Diane M Houtman.
Abstract
PURPOSE: To evaluate whether visual performance could be improved in pseudophakic subjects by correcting low levels of postoperative astigmatism.Entities:
Keywords: aspheric intraocular lens; astigmatism; cataract surgery; contrast sensitivity; reading acuity; visual acuity
Year: 2012 PMID: 22399846 PMCID: PMC3295631 DOI: 10.2147/OPTH.S28241
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Figure 1High-contrast (100%) and low-contrast (25% and 9%) visual acuity with full correction versus spherical equivalent correction (N = 37).
Note: Error bars represent standard error of the mean.
Abbreviation: logMAR, logarithm of the minimum angle of resolution.
Mean differences in contrast sensitivity between full correction and spherical equivalent correction (N = 38)
| Contrast sensitivity condition | Mean difference | |||
|---|---|---|---|---|
|
| ||||
| 3 cpd | 6 cpd | 12 cpd | 18 cpd | |
| Photopic without glare | 0.008 ± 0.04 | 0.01 ± 0.04 | 0.01 ± 0.06 | 0.02 ± 0.05 |
| Mesopic without glare | −0.05 ± 0.05 | 0.12 ± 0.06 | 0.03 ± 0.06 | 0.02 ± 0.05 |
| Mesopic with glare | 0.02 ± 0.04 | 0.03 ± 0.05 | 0.03 ± 0.045 | 0.07 ± 0.04 |
Notes:
Mean difference = score with full correction – score with spherical equivalent correction;
P = 0.046.
Abbreviations: cpd, cycles per degree; logMAR, logarithm of the minimum angle of resolution; SEM, standard error of the mean.
Figure 2Mean differences in reading speed across print sizes between use of full correction and spherical equivalent correction (N = 37).
Notes: Error bars represent standard error of the mean; *Hommel’s adjusted P value, P < 0.05.
Abbreviation: logRAD, logarithm of the reading acuity determination; SE, spherical equivalent.
Mean differences in additional Radner reading test outcomes between full correction and spherical equivalent correction (N = 37)
| Outcome | Mean difference | |
|---|---|---|
| Corrected critical print size, logRAD | 0.02 (−0.09, 0.14) | 0.6803 |
| Reading acuity @ 40 cm, logRAD | −0.02 (−0.04, −0.001) | 0.0376 |
| Corrected maximum reading speed, words/minute | 19.2 (10.4, 28.0) | <0.001 |
| LogMAR/logRAD ratio | −6.54 (−9.95, −3.12) | <0.001 |
Notes:
Mean difference = score with full correction – score with spherical equivalent correction;
P values signify statistically significant differences, all of which favored outcomes using full correction.
Abbreviations: logMAR, logarithm of the minimum angle of resolution; logRAD, logarithm of the reading acuity determination.