Literature DB >> 17543177

Contrast sensitivity and higher-order aberrations in patients with astigmatism.

Guang-ying Zheng1, Jun Du, Jin-song Zhang, Su-bing Liu, Xiao-li Nie, Xiao-hong Zhu, Xiu-xia Tang, Bao-li Xin, Zhi-bin Mai, Wei-xia Zhang.   

Abstract

BACKGROUND: Astigmatism is one of the most significant obstacles for achieving satisfactory visual function. This study was to evaluate the influence of astigmatism on contrast sensitivity (CS) and higher-order aberrations.
METHODS: CS, accommodation response and wavefront aberration were measured in 113 patients with astigmatism, aged 18 - 36 years. Both single and binocular visual performance were examined under four lighting conditions: photopia, photopia with glare, scotopia and scotopia with glare respectively. Accommodation response was classified as normal, abnormal and low. The contribution of the power and axis of astigmatism to CS, accommodation response and wavefront aberration was analyzed.
RESULTS: As the dioptric power of astigmatism increased, the loss of CS spatial frequency changed from high to intermediate, and then to low frequency. CS scores varied at different illuminance levels, descending in the following sequence: photopia, photopia with glare, scotopia, and scotopia with glare. However, the normal accommodation group showed better CS values under photopia with glare than without glare. The range of influenced direction of sine-wave gratings remained mostly at the meridian line of high dioptric power, which would be expanded when optical accommadation attenuated. The patients with symmetrical astigmatism got higher CS scores with binoculus vision than with dominant eye vision, while the patients with asymmetrical astigmatism did this only at scotopia with glare. Among higher-order aberrations, coma aberration, secondary coma aberration and the total higher order aberration were influenced by astigmatism, all of which rising with the power of astigmatism increased.
CONCLUSIONS: Reducing astigmatism might improve the performance of visual function. Not only the power of astigmatism should be cut down, but also the binocular axes should be made symmetrically.

Entities:  

Mesh:

Year:  2007        PMID: 17543177

Source DB:  PubMed          Journal:  Chin Med J (Engl)        ISSN: 0366-6999            Impact factor:   2.628


  6 in total

1.  Visual performance in cataract patients with low levels of postoperative astigmatism: full correction versus spherical equivalent correction.

Authors:  Robert P Lehmann; Diane M Houtman
Journal:  Clin Ophthalmol       Date:  2012-03-02

2.  Higher-order aberrations in myopic eyes.

Authors:  Farid Karimian; Sepehr Feizi; Azade Doozande
Journal:  J Ophthalmic Vis Res       Date:  2010-01

3.  Normal range of cambridge low contrast test; a population based study.

Authors:  Hadi Ostadimoghaddam; Akbar Fotouhi; Hassan Hashemi; Abbas Ali Yekta; Javad Heravian; Tahereh Abdolahinia; Reza Norouzi Rad; Soheila Asgari; Mehdi Khabazkhoob
Journal:  J Ophthalmic Vis Res       Date:  2014-01

4.  Successful Surgical Correction of Astigmatism using Customized Ablation Photorefractive Keratectomy.

Authors:  Hakimeh Taheri; Shahrokh Ramin
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2016

5.  Induced Higher-order aberrations after Laser In Situ Keratomileusis (LASIK) Performed with Wavefront-Guided IntraLase Femtosecond Laser in moderate to high Astigmatism.

Authors:  Ferial M Al-Zeraid; Uchechukwu L Osuagwu
Journal:  BMC Ophthalmol       Date:  2016-03-22       Impact factor: 2.209

6.  Correlation of higher order aberrations and components of astigmatism in myopic refractive surgery candidates.

Authors:  Mehrdad Mohammadpour; Zahra Heidari; Hossein Mohammad-Rabei; Ebrahim Jafarzadehpur; Mahmoud Jabbarvand; Hassan Hashemi; Mehdi Khabazkhoob
Journal:  J Curr Ophthalmol       Date:  2016-06-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.