Literature DB >> 22388729

The role of hearing preservation on electrical thresholds and speech performances in cochlear implantation.

Alessandra D'Elia1, Roberto Bartoli, Francesca Giagnotti, Nicola Quaranta.   

Abstract

OBJECTIVE: The purpose of this study was to verify if the preservation of residual hearing after cochlear implantation in classic adult cochlear implant candidates implanted with a perimodiolar electrode correlates with the electric thresholds and with speech perception measures. STUDY
DESIGN: Retrospective study.
SETTING: Cochlear Implant Center at a tertiary referral University Hospital. PATIENTS: Forty-one patients with cochlear implant were involved in our study. They were subdivided into 2 groups according to the average preoperative hearing loss at the frequencies of 125 and 250 Hz (low-frequency pure tone average [LFPTA]). Group A included 21 patients with a mean LFPTA of 90 dB HL or lower; group B included 20 patients with a mean LFPTA of greater than 90 dB HL. They underwent 12 months' follow-up after cochlear implantation, including standard audiologic investigation, speech discrimination tests, and electrical measurements.
RESULTS: No significant differences were found in speech perception tests among groups. In group A, hearing was preserved in 8 (group A1) and was lost in 13 patients (group A2); the postoperative LFPTA was significantly better (p < 0.0001) in A1. Group A1 patients present significantly higher C values (p < 0.0001) than the other 2 groups, and the dynamic range was therefore significantly wider (p < 0.001).
CONCLUSION: Preservation of residual hearing should be attempted in all cases. In fact, although effects on the speech perception are not evident with the standard evaluation, larger electrical dynamic range can be achieved and may represent a sign of cochlear "well-being," potentially allowing a more complex electric stimulation of the nerve.

Entities:  

Mesh:

Year:  2012        PMID: 22388729     DOI: 10.1097/MAO.0b013e3182487dbb

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  10 in total

1.  Cochlear implantation with the nucleus slim modiolar electrode (CI532): a preliminary experience.

Authors:  Domenico Cuda; Alessandra Murri
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-10-14       Impact factor: 2.503

2.  Cochlear implantation using the underwater technique: long-term results.

Authors:  Konrad Johannes Stuermer; David Schwarz; Andreas Anagiotos; Ruth Lang-Roth; Karl-Bernd Hüttenbrink; Jan Christoffer Luers
Journal:  Eur Arch Otorhinolaryngol       Date:  2018-02-07       Impact factor: 2.503

3.  Timing of Acoustic Hearing Changes After Cochlear Implantation.

Authors:  Megan J Jensen; Heba Isaac; Helin Hernandez; Jacob Oleson; Camille Dunn; Bruce J Gantz; Marlan R Hansen
Journal:  Laryngoscope       Date:  2021-12-09       Impact factor: 2.970

4.  Comparisons between detection threshold and loudness perception for individual cochlear implant channels.

Authors:  Julie Arenberg Bierer; Amberly D Nye
Journal:  Ear Hear       Date:  2014 Nov-Dec       Impact factor: 3.570

5.  Intracochlear pressure changes due to round window opening: a model experiment.

Authors:  P Mittmann; A Ernst; I Todt
Journal:  ScientificWorldJournal       Date:  2014-05-22

6.  Binaural fusion and listening effort in children who use bilateral cochlear implants: a psychoacoustic and pupillometric study.

Authors:  Morrison M Steel; Blake C Papsin; Karen A Gordon
Journal:  PLoS One       Date:  2015-02-10       Impact factor: 3.240

Review 7.  Factors affecting residual hearing preservation in cochlear implantation.

Authors:  D Zanetti; N Nassif; L O Redaelli de Zinis
Journal:  Acta Otorhinolaryngol Ital       Date:  2015-12       Impact factor: 2.124

8.  Intracochlear Pressure Changes After Cochlea Implant Electrode Pullback-Reduction of Intracochlear Trauma.

Authors:  Gina Lauer; Julica Uçta; Lars Decker; Arneborg Ernst; Philipp Mittmann
Journal:  Laryngoscope Investig Otolaryngol       Date:  2019-07-11

9.  Assessment of cochlear trauma and telemetry measures after cochlear implantation: A comparative study between Nucleus® CI512 and CI532 electrode arrays.

Authors:  Domenico Cuda; Alessandra Murri
Journal:  Audiol Res       Date:  2019-07-11

10.  Correlation between Speech Perception Outcomes after Cochlear Implantation and Postoperative Acoustic and Electric Hearing Thresholds.

Authors:  Ursina Rüegg; Adrian Dalbert; Dorothe Veraguth; Christof Röösli; Alexander Huber; Flurin Pfiffner
Journal:  J Clin Med       Date:  2021-01-17       Impact factor: 4.241

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.