INTRODUCTION: The opening of the round window and the insertion of the electrode array into the scala tympani during cochlear implant surgery can lead to a pressure shock of the delicate inner ear structures. By filling the tympanic cavity with Ringer Solution during these surgical steps (underwater technique), the hydrostatic pressure of the fluid acts as a smooth pressure stabilizer, avoiding a pressure shock of the inner ear structures. The aim of this retrospective study was to present long-term results of this new method of cochlear implantation in underwater technique.
METHODS: Altogether, 47 implantations in 43 patients with residual hearing at the frequencies 250, 500 and 1000 Hz in the unaided preoperative pure tone audiometry were included. A cochlear implantation via round window with a conventional full-length electrode was performed in underwater technique. Changes of residual hearing 7 weeks and 24 months after surgery were analyzed.
RESULTS: Overall postimplant hearing preservation 7 weeks after implantation was achieved in 22 ears (47%). Subsequent follow-up was performed on average 24 months after surgery (range 12 months-4.2 years) in all patients. At this late postoperative evaluation, preservation of hearing was recorded in 18 ears (38%). Neither the follow-up time nor the type of electrode had a significant impact on the postoperative hearing loss.
CONCLUSION: The underwater technique is an atraumatic cochlear implantation technique with hearing preservation rates comparable to results in literature and a very small hearing preservation decline rate over time even when using full-length CI electrodes.

Entities:  

Keywords:  Atraumatic surgery; Cochlear implantation; Electrodes; Hearing preservation; Residual hearing

Mesh:

Substances:

Year:  2018        PMID: 29417275     DOI: 10.1007/s00405-018-4886-7

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  37 in total

1.  Preservation of cochlear structures and hearing when using the Nucleus Slim Straight (CI422) electrode in children.

Authors:  H Skarzynski; M Matusiak; A Lorens; M Furmanek; A Pilka; P H Skarzynski
Journal:  J Laryngol Otol       Date:  2016-01-14       Impact factor: 1.469

2.  Does the surgical approach in cochlear implantation influence the occurrence of postoperative vertigo?

Authors:  Ingo Todt; Dietmar Basta; Arne Ernst
Journal:  Otolaryngol Head Neck Surg       Date:  2008-01       Impact factor: 3.497

3.  An evaluation of the preservation of residual hearing with the Nucleus Contour Advance electrode.

Authors:  Luis Garcia-Ibanez; Angel Ramos Macias; Constantino Morera; Manuel Manrique Rodriguez; Witold Szyfter; Henryk Skarszynski; Hessam Emamdjomeh; Wolf-Dieter Baumgartner
Journal:  Acta Otolaryngol       Date:  2009-06       Impact factor: 1.494

Review 4.  Electric-acoustic stimulation of the auditory system: a review of the first decade.

Authors:  Christoph A von Ilberg; Uwe Baumann; Jan Kiefer; Jochen Tillein; Oliver F Adunka
Journal:  Audiol Neurootol       Date:  2011-05-24       Impact factor: 1.854

Review 5.  Surgical aspects of cochlear implantation: mechanisms of insertional trauma.

Authors:  Peter S Roland; Charles G Wright
Journal:  Adv Otorhinolaryngol       Date:  2006

6.  The Impact of Electrode Array Length on Hearing Preservation in Cochlear Implantation.

Authors:  Marie-Charlot Suhling; Omid Majdani; Rolf Salcher; Melanie Leifholz; Andreas Büchner; Anke Lesinski-Schiedat; Thomas Lenarz
Journal:  Otol Neurotol       Date:  2016-09       Impact factor: 2.311

7.  Predictive factors for short- and long-term hearing preservation in cochlear implantation with conventional-length electrodes.

Authors:  George B Wanna; Brendan P O'Connell; David O Francis; Rene H Gifford; Jacob B Hunter; Jourdan T Holder; Marc L Bennett; Alejandro Rivas; Robert F Labadie; David S Haynes
Journal:  Laryngoscope       Date:  2017-06-22       Impact factor: 3.325

8.  Reimplantation of hybrid cochlear implant users with a full-length electrode after loss of residual hearing.

Authors:  Matthew B Fitzgerald; Elad Sagi; Michael Jackson; William H Shapiro; J Thomas Roland; Susan B Waltzman; Mario A Svirsky
Journal:  Otol Neurotol       Date:  2008-02       Impact factor: 2.311

9.  Insertion of Cochlear Implant Electrode Array Using the Underwater Technique for Preserving Residual Hearing.

Authors:  Andreas Anagiotos; Dirk Beutner; Antoniu-Oreste Gostian; David Schwarz; Jan-Christoffer Luers; Karl-Bernd Hüttenbrink
Journal:  Otol Neurotol       Date:  2016-04       Impact factor: 2.311

Review 10.  Hearing preservation in cochlear implant surgery.

Authors:  Priscila Carvalho Miranda; André Luiz Lopes Sampaio; Rafaela Aquino Fernandes Lopes; Alessandra Ramos Venosa; Carlos Augusto Costa Pires de Oliveira
Journal:  Int J Otolaryngol       Date:  2014-09-03
View more
  4 in total

1.  Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion: Effect of Micro-mechanical Control on Limiting Pressure Trauma.

Authors:  Renee M Banakis Hartl; Christopher Kaufmann; Marlan R Hansen; Daniel J Tollin
Journal:  Otol Neurotol       Date:  2019-07       Impact factor: 2.311

2.  [Hearing preservation in children with electric-acoustic stimulation after cochlear implantation : Outcome after electrode insertion with minimal insertion trauma (German version)].

Authors:  T Rader; A Bohnert; C Matthias; D Koutsimpelas; M-A Kainz; S Strieth
Journal:  HNO       Date:  2018-09       Impact factor: 1.284

3.  Intracochlear Pressure Changes After Cochlea Implant Electrode Pullback-Reduction of Intracochlear Trauma.

Authors:  Gina Lauer; Julica Uçta; Lars Decker; Arneborg Ernst; Philipp Mittmann
Journal:  Laryngoscope Investig Otolaryngol       Date:  2019-07-11

4.  Hearing preservation in children with electric-acoustic stimulation after cochlear implantation : Outcome after electrode insertion with minimal insertion trauma.

Authors:  T Rader; A Bohnert; C Matthias; D Koutsimpelas; M-A Kainz; S Strieth
Journal:  HNO       Date:  2018-07       Impact factor: 1.284

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.