Literature DB >> 22365424

Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation.

Hasan Jilaihawi1, Mohammad Kashif, Gregory Fontana, Azusa Furugen, Takahiro Shiota, Gerald Friede, Rakhee Makhija, Niraj Doctor, Martin B Leon, Raj R Makkar.   

Abstract

OBJECTIVES: In an effort to define the gold standard for annular sizing for transcatheter aortic valve replacement (TAVR), we sought to critically analyze and compare the predictive value of multiple measures of the aortic annulus for post-TAVR paravalvular (PV) regurgitation and then assess the impact of a novel cross-sectional computed tomographic (CT) approach to annular sizing.
BACKGROUND: Recent studies have shown clear discrepancies between conventional 2-dimensional (2D) echocardiographic and CT measurements. In terms of aortic annular measurement for TAVR, such findings have lacked the outcome analysis required to inform clinical practice.
METHODS: The discriminatory value of multiple CT annular measures for post-TAVR PV aortic regurgitation was compared with 2D echocardiographic measures. TAVR outcomes with device selection according to aortic annular sizing using a traditional 2D transesophageal echocardiography-guided or a novel CT-guided approach were also studied.
RESULTS: In receiver-operating characteristic models, cross-sectional CT parameters had the highest discriminatory value for post-TAVR PV regurgitation: This was with the area under the curve for [maximal cross-sectional diameter minus prosthesis size] of 0.82 (95% confidence interval: 0.69 to 0.94; p < 0.001) and that for [circumference-derived cross-sectional diameter minus prosthesis size] of 0.81 (95% confidence interval: 0.7 to 0.94; p < 0.001). In contrast, traditional echocardiographic measures were nondiscriminatory in relation to post-TAVR PV aortic regurgitation. The prospective application of a CT-guided annular sizing approach resulted in less PV aortic regurgitation of grade worse than mild after TAVR (7.5% vs. 21.9%; p = 0.045).
CONCLUSIONS: Our data lend strong support to 3-dimensional cross-sectional measures, using CT as the new gold standard for aortic annular evaluation for TAVR with the Edwards SAPIEN device.
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22365424     DOI: 10.1016/j.jacc.2011.11.045

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  92 in total

1.  Assessment of annular distensibility in the aortic valve.

Authors:  John O'Dea; David J Nolan
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-06-13

Review 2.  Role of Cardiac CT Before Transcatheter Aortic Valve Implantation (TAVI).

Authors:  Mohamed Marwan; Stephan Achenbach
Journal:  Curr Cardiol Rep       Date:  2016-02       Impact factor: 2.931

3.  Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing.

Authors:  Won-Keun Kim; Alexander Meyer; Helge Möllmann; Andreas Rolf; Susanne Möllmann; Johannes Blumenstein; Arnaud Van Linden; Christian W Hamm; Thomas Walther; Jörg Kempfert
Journal:  Clin Res Cardiol       Date:  2016-02-18       Impact factor: 5.460

4.  Sizing the aortic annulus.

Authors:  Alfredo G Cerillo; Massimiliano Mariani; Sergio Berti; Mattia Glauber
Journal:  Ann Cardiothorac Surg       Date:  2012-07

Review 5.  Advanced 3-D analysis, client-server systems, and cloud computing-Integration of cardiovascular imaging data into clinical workflows of transcatheter aortic valve replacement.

Authors:  Paul Schoenhagen; Mathis Zimmermann; Juergen Falkner
Journal:  Cardiovasc Diagn Ther       Date:  2013-06

Review 6.  Workup and Management of Patients With Paradoxical Low-Flow, Low-Gradient Aortic Stenosis.

Authors:  Mohamed-Salah Annabi; Marine Clisson; Marie-Annick Clavel; Philippe Pibarot
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-05-02

Review 7.  The role of echocardiography in transcatheter aortic valve implantation.

Authors:  Toshinari Onishi; Kaoruko Sengoku; Yasuhiro Ichibori; Isamu Mizote; Koichi Maeda; Toru Kuratani; Yoshiki Sawa; Yasushi Sakata
Journal:  Cardiovasc Diagn Ther       Date:  2018-02

Review 8.  Transcatheter aortic valve repair, imaging, and electronic imaging health record.

Authors:  Paul Schoenhagen; Juergen Falkner; David Piraino
Journal:  Curr Cardiol Rep       Date:  2013-01       Impact factor: 2.931

9.  Comparison of aortic root dimension changes during cardiac cycle between the patients with and without aortic valve calcification using ECG-gated 64-slice and dual-source 256-slice computed tomography scanners: results of a multicenter study.

Authors:  Abbas Arjmand Shabestari; Ramin Pourghorban; Mahmood Tehrai; Hamidreza Pouraliakbar; Taraneh Faghihi Langroudi; Hooman Bakhshandeh; Seifollah Abdi
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-13       Impact factor: 2.357

10.  Gated thoracic magnetic resonance angiography at 3T: noncontrast versus blood pool contrast.

Authors:  Chengcheng Zhu; Henrik Haraldsson; Kimberly Kallianos; Liang Ge; Elaine Tseng; Travis Henry; David Saloner; Michael D Hope
Journal:  Int J Cardiovasc Imaging       Date:  2017-09-13       Impact factor: 2.357

View more