Literature DB >> 22360677

Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD: design and rationale of the EFFORTLESS S-ICD Registry.

Susanne S Pedersen1, Pier Lambiase, Lucas V A Boersma, Francis Murgatroyd, Jens Brock Johansen, Helen Reeve, A Graham Stuart, Pedro Adragao, Dominic A M J Theuns.   

Abstract

BACKGROUND: Leads in and on the heart of the transvenous implantable cardioverter defibrillator (ICD) form the Achilles' heel of this system due to potential for peri- and postimplant complications. The S-ICD is a newer generation of the ICD that does not require leads on the heart or in the vasculature. We present the rationale and study design of the Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD (EFFORTLESS S-ICD) Registry which was designed to evaluate the long-term performance of the S-ICD including patient quality of life and long-term resource utilization.
METHODS: The Registry is an observational, nonrandomized, standard of care evaluation to be conducted at approximately 50 investigational centers in Europe and New Zealand where the S-ICD is approved for use and distribution. Clinical Registry endpoints include perioperative (30 days postimplant) complication-free rate, 360-day complication-free rate, and percentage of inappropriate shocks for atrial fibrillation and supraventricular ventricular tachyarrhythmia. Other endpoints include patient-reported outcomes (e.g., quality of life) and hospital personnel implant and follow-up experience with the S-ICD system.
CONCLUSIONS: Results from EFFORTLESS will build on and expand the initial published experience with the S-ICD, which demonstrated that the device successfully and consistently detects and treats episodes of sustained ventricular tachyarrhythmias. The Registry will also evaluate the patients' perspective of how it is to live with an S-ICD as compared to a contemporary transvenous system and track the experience of implanting physicians and personnel performing patient follow-up with a completely subcutaneous system. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22360677     DOI: 10.1111/j.1540-8159.2012.03337.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  11 in total

Review 1.  [Implantable cardioverter defibrillator].

Authors:  C Stellbrink; D Andresen; D Böcker; T Lewalter
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-03

Review 2.  Clinical experience with subcutaneous implantable cardioverter-defibrillators.

Authors:  Geoffrey F Lewis; Michael R Gold
Journal:  Nat Rev Cardiol       Date:  2015-04-21       Impact factor: 32.419

Review 3.  Subcutaneous and Transvenous ICDs: an Update on Contemporary Questions and Controversies.

Authors:  Daniel J Friedman; Albert S Tully; Emily P Zeitler
Journal:  Curr Cardiol Rep       Date:  2022-05-31       Impact factor: 3.955

Review 4.  Subcutaneous implantable defibrillator: State-of-the art 2013.

Authors:  Finn Akerström; Miguel A Arias; Marta Pachón; Alberto Puchol; Jesús Jiménez-López
Journal:  World J Cardiol       Date:  2013-09-26

5.  Initial experience with the subcutaneous implantable cardioverter-defibrillator with the real costs of hospitalization analysis in a single Polish center.

Authors:  Marcin Grabowski; Monika Gawałko; Marcin Michalak; Andrzej Cacko; Michał Kowara; Agnieszka Kołodzińska; Łukasz Januszkiewicz; Paweł Balsam; Laura Vitali Serdoz; Joachim Winter; Grzegorz Opolski
Journal:  Cardiol J       Date:  2018-04-03       Impact factor: 2.737

6.  Subcutaneous implantable cardioverter-defibrillators: long-term results of the EFFORTLESS study.

Authors:  Pier D Lambiase; Dominic A Theuns; Francis Murgatroyd; Craig Barr; Lars Eckardt; Petr Neuzil; Marcoen Scholten; Margaret Hood; Jȕrgen Kuschyk; Amy J Brisben; Nathan Carter; Timothy M Stivland; Reinoud Knops; Lucas V A Boersma
Journal:  Eur Heart J       Date:  2022-06-01       Impact factor: 35.855

7.  Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry.

Authors:  Pier D Lambiase; Craig Barr; Dominic A M J Theuns; Reinoud Knops; Petr Neuzil; Jens Brock Johansen; Margaret Hood; Susanne Pedersen; Stefan Kääb; Francis Murgatroyd; Helen L Reeve; Nathan Carter; Lucas Boersma
Journal:  Eur Heart J       Date:  2014-03-26       Impact factor: 29.983

Review 8.  The entirely subcutaneous defibrillator (s-icd): state of the art and selection of the ideal candidate.

Authors:  Elia De Maria; Alina Olaru; Stefano Cappelli
Journal:  Curr Cardiol Rev       Date:  2015

9.  Evaluation of subcutaneous implantable cardioverter-defibrillator performance in patients with ion channelopathies from the EFFORTLESS cohort and comparison with a meta-analysis of transvenous ICD outcomes.

Authors:  Pier D Lambiase; Lars Eckardt; Dominic A Theuns; Timothy R Betts; Andreas L Kyriacou; Elizabeth Duffy; Reinoud Knops
Journal:  Heart Rhythm O2       Date:  2020-10-28

Review 10.  Early experience with the subcutaneous ICD.

Authors:  Pier D Lambiase; Neil T Srinivasan
Journal:  Curr Cardiol Rep       Date:  2014-08       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.