Literature DB >> 22357385

Graft biomechanical properties after penetrating keratoplasty in keratoconus.

Sepehr Feizi1, Bahram Einollahi, Shahin Yazdani, Ali Hashemloo.   

Abstract

PURPOSE: To measure corneal graft biomechanical properties after penetrating keratoplasty (PKP) in a group of keratoconic eyes using the ocular response analyzer (ORA) and to evaluate the relationship between donor size, donor-recipient disparity and central graft thickness (CGT), and ORA parameters.
METHODS: This cross-sectional study was conducted on 34 eyes of 34 keratoconus patients who had undergone PKP. Corneal hysteresis (CH), corneal resistance factor (CRF), and cornea-compensated intraocular pressure were measured at least 6 months after complete suture removal. Two groups of donor-recipient disparity (0.25 vs. 0.50 mm) were compared using the independent t test. Multivariate regression analysis was used to investigate the correlation of donor trephine size and CGT with ORA parameters. Factors influencing intraocular pressure measured with the Goldmann applanation tonometer (IOP GAT) after PKP were determined using multiple regression analysis.
RESULTS: Mean patient age and follow-up period were 29.6 ± 6.2 years and 82.4 ± 59.6 months, respectively. Mean CGT, CH, and CRF were 564.7 ± 36.9 μm, 10.1 ± 2.1 mm Hg, and 10.0 ± 2.3 mm Hg, respectively. CH and CRF had a significant positive correlation with donor trephine size and CGT. Significantly greater values of CH and CRF were observed in the 0.5-mm disparity group compared with the 0.25-mm disparity group. Among the studied parameters, only CH, CRF, and cornea-compensated intraocular pressure had a significant positive correlation with IOP GAT.
CONCLUSION: Graft biomechanics seem to be closer to normal values with larger grafts and greater donor-recipient disparity. These metrics had a significant correlation with IOP GAT after PKP.

Entities:  

Mesh:

Year:  2012        PMID: 22357385     DOI: 10.1097/ICO.0b013e31823f8ce4

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  8 in total

1.  Corneal biomechanical properties in eyes with no previous surgery, with previous penetrating keratoplasty and with deep anterior lamellar keratoplasty.

Authors:  Banu Torun Acar; Mehmet Orcun Akdemir; Suphi Acar
Journal:  Jpn J Ophthalmol       Date:  2012-11-03       Impact factor: 2.447

2.  Long-term outcomes of penetrating keratoplasty in keratoconus: analysis of the factors associated with final visual acuities.

Authors:  Jin A Choi; Min A Lee; Man-Soo Kim
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

3.  Surgical outcome of deep anterior lamellar keratoplasty with air-assisted manual dissection for corneas with previous inflammation or fibrosis.

Authors:  Yi-Ju Ho; Cheng-Hsiu Wu; Hung-Chi Chen; Chin-Shi Hsiao; Yi-Jen Hsueh; David Hui-Kang Ma
Journal:  Taiwan J Ophthalmol       Date:  2017 Oct-Dec

4.  Corneal biomechanics and intraocular pressure assessment after penetrating keratoplasty for non keratoconic patients, long term results.

Authors:  Mohamed Samy Abd Elaziz; Hoda Mohamed Elsobky; Adel Galal Zaky; Eslam Ahmed Maher Hassan; Mahmoud Tawfik KhalafAllah
Journal:  BMC Ophthalmol       Date:  2019-08-07       Impact factor: 2.209

Review 5.  Intraocular Pressure Measurement after Penetrating Keratoplasty.

Authors:  Otilia-Maria Dumitrescu; Sinziana Istrate; Mioara-Laura Macovei; Alina Gabriela Gheorghe
Journal:  Diagnostics (Basel)       Date:  2022-01-19

Review 6.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

7.  Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer.

Authors:  Vanathi Murugesan; Ravi Bypareddy; Mahesh Kumar; Dada Tanuj; Panda Anita
Journal:  Indian J Ophthalmol       Date:  2014-04       Impact factor: 1.848

8.  Corneal Biomechanical Properties of Keratoconic Eyes Following Penetrating Keratoplasty.

Authors:  Hamidu Gobeka; Özlem Barut Selver; Melis Palamar Onay; Sait Eğrilmez; Ayşe Yağcı
Journal:  Turk J Ophthalmol       Date:  2018-09-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.