Literature DB >> 22344580

Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery.

Ting Song1, Jeffrey A Stainsby, Vincent B Ho, Maureen N Hood, Glenn S Slavin.   

Abstract

A modified Look-Locker acquisition using saturation recovery (MLLSR) for breath-held myocardial T(1) mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T(1) mapping because it does not require time for magnetization to relax to equilibrium. Therefore, MLLSR enables segmented readouts, shorter data acquisition windows, and shorter breath holds compared with inversion recovery. T(1) measurements in phantoms using MLLSR showed a high correlation with conventional single-point inversion recovery spin echo. In vivo T(1) measurements from normal and infarcted myocardium in 41 volunteers and patients were consistent with previously reported values. Twenty subjects were also scanned with MLLSR using an accelerated sampling scheme that required half the scan time (eight vs. 16 heartbeats) but yielded equivalent results. The flexibility afforded by the improved imaging efficiency of MLLSR allows the acquisition to be tailored to particular clinical needs and to individual patient's breath-holding abilities.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22344580     DOI: 10.1002/mrm.24137

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Wideband arrhythmia-Insensitive-rapid (AIR) pulse sequence for cardiac T1 mapping without image artifacts induced by an implantable-cardioverter-defibrillator.

Authors:  KyungPyo Hong; Eun-Kee Jeong; T Scott Wall; Stavros G Drakos; Daniel Kim
Journal:  Magn Reson Med       Date:  2015-05-14       Impact factor: 4.668

2.  Optimized AIR and investigational MOLLI cardiac T1 mapping pulse sequences produce similar intra-scan repeatability in patients at 3T.

Authors:  KyungPyo Hong; Jeremy Collins; Daniel C Lee; Jane E Wilcox; Michael Markl; James Carr; Daniel Kim
Journal:  NMR Biomed       Date:  2016-09-05       Impact factor: 4.044

3.  MOLLI and AIR T1 mapping pulse sequences yield different myocardial T1 and ECV measurements.

Authors:  KyungPyo Hong; Daniel Kim
Journal:  NMR Biomed       Date:  2014-11       Impact factor: 4.044

4.  Free-breathing post-contrast three-dimensional T1 mapping: Volumetric assessment of myocardial T1 values.

Authors:  Sebastian Weingärtner; Mehmet Akçakaya; Sébastien Roujol; Tamer Basha; Christian Stehning; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02-05       Impact factor: 4.668

5.  Evaluation of age-related interstitial myocardial fibrosis with cardiac magnetic resonance contrast-enhanced T1 mapping: MESA (Multi-Ethnic Study of Atherosclerosis).

Authors:  Chia-Ying Liu; Yuan-Chang Liu; Colin Wu; Anderson Armstrong; Gustavo J Volpe; Rob J van der Geest; Yongmei Liu; William G Hundley; Antoinette S Gomes; Songtao Liu; Marcelo Nacif; David A Bluemke; João A C Lima
Journal:  J Am Coll Cardiol       Date:  2013-07-17       Impact factor: 24.094

6.  Dose correction for post-contrast T1 mapping of the heart: the MESA study.

Authors:  Neville D Gai; Veit Sandfort; Songtao Liu; João A C Lima; David A Bluemke
Journal:  Int J Cardiovasc Imaging       Date:  2015-09-11       Impact factor: 2.357

7.  Accelerated and navigator-gated look-locker imaging for cardiac T1 estimation (ANGIE): Development and application to T1 mapping of the right ventricle.

Authors:  Bhairav B Mehta; Xiao Chen; Kenneth C Bilchick; Michael Salerno; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2014-02-11       Impact factor: 4.668

8.  Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE.

Authors:  Sébastien Roujol; Sebastian Weingärtner; Murilo Foppa; Kelvin Chow; Keigo Kawaji; Long H Ngo; Peter Kellman; Warren J Manning; Richard B Thompson; Reza Nezafat
Journal:  Radiology       Date:  2014-04-04       Impact factor: 11.105

Review 9.  T1-mapping in the heart: accuracy and precision.

Authors:  Peter Kellman; Michael S Hansen
Journal:  J Cardiovasc Magn Reson       Date:  2014-01-04       Impact factor: 5.364

10.  Fast myocardial T1 mapping using shortened inversion recovery based schemes.

Authors:  Li Huang; Radhouene Neji; Muhummad Sohaib Nazir; John Whitaker; Fiona Reid; Filippo Bosio; Amedeo Chiribiri; Reza Razavi; Sébastien Roujol
Journal:  J Magn Reson Imaging       Date:  2019-01-22       Impact factor: 4.813

  10 in total