Literature DB >> 22341081

Computed micro-tomographic evaluation of glide path with nickel-titanium rotary PathFile in maxillary first molars curved canals.

Damiano Pasqualini1, Caterina Chiara Bianchi, Davide Salvatore Paolino, Lucia Mancini, Andrea Cemenasco, Giuseppe Cantatore, Arnaldo Castellucci, Elio Berutti.   

Abstract

INTRODUCTION: X-ray computed micro-tomography scanning allows high-resolution 3-dimensional imaging of small objects. In this study, micro-CT scanning was used to compare the ability of manual and mechanical glide path to maintain the original root canal anatomy.
METHODS: Eight extracted upper first permanent molars were scanned at the TOMOLAB station at ELETTRA Synchrotron Light Laboratory in Trieste, Italy, with a microfocus cone-beam geometry system. A total of 2,400 projections on 360° have been acquired at 100 kV and 80 μA, with a focal spot size of 8 μm. Buccal root canals of each specimen (n = 16) were randomly assigned to PathFile (P) or stainless-steel K-file (K) to perform glide path at the full working length. Specimens were then microscanned at the apical level (A) and at the point of the maximum curvature level (C) for post-treatment analyses. Curvatures of root canals were classified as moderate (≤35°) or severe (≥40°). The ratio of diameter ratios (RDRs) and the ratio of cross-sectional areas (RAs) were assessed. For each level of analysis (A and C), 2 balanced 2-way factorial analyses of variance (P < .05) were performed to evaluate the significance of the instrument factor and of canal curvature factor as well as the interactions of the factors both with RDRs and RAs.
RESULTS: Specimens in the K group had a mean curvature of 35.4° ± 11.5°; those in the P group had a curvature of 38° ± 9.9°. The instrument factor (P and K) was extremely significant (P < .001) for both the RDR and RA parameters, regardless of the point of analysis.
CONCLUSIONS: Micro-CT scanning confirmed that NiTi rotary PathFile instruments preserve the original canal anatomy and cause less canal aberrations. Copyright Â
© 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22341081     DOI: 10.1016/j.joen.2011.11.011

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  15 in total

1.  Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Authors:  Ana Arias; Rupinderpal Singh; Ove A Peters
Journal:  Odontology       Date:  2015-02-21       Impact factor: 2.634

Review 2.  Endodontic Rotary Files, What Should an Endodontist Know?

Authors:  Ana-Belén Dablanca-Blanco; Pablo Castelo-Baz; Ramón Miguéns-Vila; Pablo Álvarez-Novoa; Benjamín Martín-Biedma
Journal:  Medicina (Kaunas)       Date:  2022-05-27       Impact factor: 2.948

3.  Canal shaping with WaveOne reciprocating files: influence of operator experience on instrument breakage and canal preparation time.

Authors:  Luigi Generali; Elena Righi; Maria Vittoria Todesca; Ugo Consolo
Journal:  Odontology       Date:  2013-06-28       Impact factor: 2.634

4.  Apical root canal transportation of different pathfinding systems and their effects on shaping ability of ProTaper Next.

Authors:  Sevinç-Aktemur Türker; Emel Uzunoğlu
Journal:  J Clin Exp Dent       Date:  2015-07-01

5.  Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro.

Authors:  Sílvio Emanuel Acioly Conrado de Menezes; Shirley Machado Batista; Juliana Ouro Preto Lira; Gabriela Queiroz de Melo Monteiro
Journal:  Iran Endod J       Date:  2017

6.  Comparison of automatic and visual methods used for image segmentation in Endodontics: a microCT study.

Authors:  Polyane Mazucatto Queiroz; Karla Rovaris; Gustavo Machado Santaella; Francisco Haiter-Neto; Deborah Queiroz Freitas
Journal:  J Appl Oral Sci       Date:  2017 Nov-Dec       Impact factor: 2.698

7.  Cone-beam computed tomography assessment of root canal transportation using WaveOne Gold and Neoniti single-file systems.

Authors:  Saritha Vallabhaneni; Kainath Fatima; Twino H Kumar
Journal:  J Conserv Dent       Date:  2017 Nov-Dec

8.  Micro-Computed Tomography (Micro-CT) Evaluation of Effects of Different Rotary Glide Path Techniques on Canal Transportation and Centering in Curved Root Canals.

Authors:  Gabrielė Česaitienė; Tadas Venskutonis; Vita Mačiulskienė; Vaidotas Cicėnas; Vykintas Samaitis; Elena Jasiūnienė
Journal:  Med Sci Monit       Date:  2019-08-24

9.  Reduction of an in vitro Intraradicular Multispecies Biofilm Using Two Rotary Instrumentation Sequences.

Authors:  Angelo Zavattini; Jonathan Cowie; Sadia Niazi; Massimo Giovarruscio; Salvatore Sauro; Federico Foschi
Journal:  Eur J Dent       Date:  2020-02-04

10.  Influence of a glide path on the dentinal crack formation of ProTaper Next system.

Authors:  Sevinç Aktemur Türker; Emel Uzunoğlu
Journal:  Restor Dent Endod       Date:  2015-09-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.