Literature DB >> 22339741

A systematic review of radiation dose associated with different generations of multidetector CT coronary angiography.

Akmal Sabarudin1, Zhonghua Sun, Kwan-Hoong Ng.   

Abstract

The purpose of this paper is to perform a systematic review on radiation dose reduction in coronary computed tomography (CT) angiography that is done using different generations of multidetector CT (MDCT) scanners ranging from four-slice to 320-slice CTs, and have different dose-saving techniques. The method followed was to search for references on coronary CT angiography (CTA) that had been published in English between 1998 and February 2011. The effective radiation dose reported in each study based on different generations of MDCT scanners was analysed and compared between the types of scanners, gender, exposure factors and scanning protocols. Sixty-six studies were eligible for inclusion in this analysis. The mean effective dose (ED) for MDCT angiography with retrospective electrocardiogram (ECG) gating without use of any dose-saving protocol was 6.0 ± 2.8, 10.4 ± 4.90 and 11.8 ± 5.9 mSv for four-slice, 16-slice and 64-slice CTs, respectively. More dose-saving strategies were applied in recent CT generations including prospective ECG-gating protocols, application of lower tube voltage and tube current modulation to achieve a noteworthy dose reduction. Prospective ECG-gating protocol was increasingly used in 64, 125, 256 and 320 slices with corresponding ED of 4.1 ± 1.7, 3.6 ± 0.4, 3.0 ± 1.9 and 7.6 ± 1.6 mSv, respectively. Lower tube voltage and tube current modulation were widely applied in 64-slice CT and resulted in significant dose reduction (P < 0.05). This analysis has shown that dose-saving strategies can substantially reduce the radiation dose in CT coronary angiography. The fact that more and more clinicians are opting for dose-saving strategies in CT coronary angiography indicates an increased awareness of risks associated with high radiation doses among them.
© 2012 The Authors. Journal of Medical Imaging and Radiation Oncology © 2012 The Royal Australian and New Zealand College of Radiologists.

Mesh:

Year:  2012        PMID: 22339741     DOI: 10.1111/j.1754-9485.2011.02335.x

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  17 in total

1.  Feasibility study of low tube voltage (80 kVp) coronary CT angiography combined with contrast medium reduction using iterative model reconstruction (IMR) on standard BMI patients.

Authors:  Fan Zhang; Li Yang; Xiang Song; Ying-Na Li; Yan Jiang; Xing-Hua Zhang; Hai-Yue Ju; Jian Wu; Rui-Ping Chang
Journal:  Br J Radiol       Date:  2015-11-26       Impact factor: 3.039

2.  Cardiac CT imaging in coronary artery disease: Current status and future directions.

Authors:  Zhonghua Sun
Journal:  Quant Imaging Med Surg       Date:  2012-06

3.  Importance of dynamic aortic evaluation in planning TEVAR.

Authors:  Guido H W van Bogerijen; Joost A van Herwaarden; Michele Conti; Ferdinando Auricchio; Vincenzo Rampoldi; Santi Trimarchi; Frans L Moll
Journal:  Ann Cardiothorac Surg       Date:  2014-05

Review 4.  Computed tomography coronary angiography - past, present and future.

Authors:  Pei Ing Ngam; Ching Ching Ong; Ping Chai; Siong Sung Wong; Chong Ri Liang; Lynette Li San Teo
Journal:  Singapore Med J       Date:  2020-03       Impact factor: 1.858

5.  256-slice CT coronary angiography: in vivo dosimetry and technique optimization.

Authors:  Manuel Belgrano; Paola Bregant; Micheline Fute Djoguela; William Toscano; Elena Marchese; Maria A Cova
Journal:  Radiol Med       Date:  2013-12-12       Impact factor: 3.469

6.  ECG-gated coronary angiography enables submillisievert imaging in invasive cardiology.

Authors:  E Kuon; S B Felix; K Weitmann; I Büchner; A Hummel; M Dörr; T Reffelmann; A Riad; M C Busch; K Empen
Journal:  Herz       Date:  2014-10-04       Impact factor: 1.443

7.  A comparison of coronary CTA and stress testing using high-efficiency SPECT MPI for the evaluation of chest pain in the emergency department.

Authors:  W Lane Duvall; John A Savino; Elliot J Levine; Usman Baber; Jonathan T Lin; Andrew J Einstein; Luke K Hermann; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2013-12-06       Impact factor: 5.952

8.  Evaluation of an adaptive detector collimation for prospectively ECG-triggered coronary CT angiography with third-generation dual-source CT.

Authors:  Michael Messerli; Patricia Dewes; Jan-Erik Scholtz; Christophe Arendt; Simon Wildermuth; Thomas J Vogl; Ralf W Bauer
Journal:  Eur Radiol       Date:  2017-12-07       Impact factor: 5.315

9.  Low-dose CT coronary angiography using iterative reconstruction with a 256-slice CT scanner.

Authors:  Patricia Carrascosa; Gastón A Rodriguez-Granillo; Carlos Capuñay; Alejandro Deviggiano
Journal:  World J Cardiol       Date:  2013-10-26

10.  Use of coronary CT angiography in the diagnosis of patients with suspected coronary artery disease: findings and clinical indications.

Authors:  Zhong-Hua Sun; Yu-Pin Liu; Dong-Jin Zhou; Yan Qi
Journal:  J Geriatr Cardiol       Date:  2012-06       Impact factor: 3.327

View more