Literature DB >> 22332063

Timing-invariant reconstruction for deriving high-quality CT angiographic data from cerebral CT perfusion data.

Ewoud J Smit1, Evert-jan Vonken, Irene C van der Schaaf, Adrienne M Mendrik, Jan Willem Dankbaar, Alexander D Horsch, Tom van Seeters, Bram van Ginneken, Mathias Prokop.   

Abstract

PURPOSE: To suggest a simple and robust technique used to reconstruct high-quality computed tomographic (CT) angiographic images from CT perfusion data and to compare it with currently used CT angiography techniques.
MATERIALS AND METHODS: Institutional review board approval was waived for this retrospective study, which included 25 consecutive patients who had had a stroke. Temporal maximum intensity projection (tMIP) CT angiographic images were created by using prior temporal filtering as a timing-insensitive technique to produce CT angiographic images from CT perfusion data. The temporal filter strength was optimized to gain maximal contrast-to-noise ratios (CNRs) in the circle of Willis. The resulting timing-invariant (TI) CT angiography was compared with standard helical CT angiography, the arterial phase of dynamic CT angiography, and nonfiltered tMIP CT angiography. Vascular contrast, image noise, and CNR were measured. Four experienced observers scored all images for vascular noise, vascular contour, detail of small and medium arteries, venous superimposition, and overall image quality in a blinded side-by-side comparison. Measurements were compared with a paired t test; P ≤ .05 indicated a significant difference.
RESULTS: On average, optimized temporal filtering in TI CT angiography increased CNR by 18% and decreased image noise by 18% at the expense of a decrease in vascular contrast of 3% when compared with nonfiltered tMIP CT angiography. CNR, image noise, vascular noise, vascular contour, detail visibility of small and medium arteries, and overall image quality of TI CT angiograms were superior to those of standard CT angiography, tMIP CT angiography, and the arterial phase of dynamic CT angiography at a vascular contrast that was similar to that of standard CT angiography. Venous superimposition was similar for all techniques. Image quality of the arterial phase of dynamic CT angiography was rated inferior to that of standard CT angiography.
CONCLUSION: TI CT angiographic images constructed by using temporally filtered tMIP CT angiographic data have excellent image quality that is superior to that achieved with currently used techniques, but they suffer from modest venous superimposition. © RSNA, 2012.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22332063     DOI: 10.1148/radiol.11111068

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  29 in total

1.  Prediction of Stent-Retriever Thrombectomy Outcomes by Dynamic Multidetector CT Angiography in Patients with Acute Carotid T or MCA Occlusions.

Authors:  K M Thierfelder; W H Sommer; B Ertl-Wagner; S E Beyer; F G Meinel; W G Kunz; G Buchholz; M F Reiser; H Janssen
Journal:  AJNR Am J Neuroradiol       Date:  2016-02-11       Impact factor: 3.825

2.  Strategies of collateral blood flow assessment in ischemic stroke: prediction of the follow-up infarct volume in conventional and dynamic CTA.

Authors:  S E Beyer; K M Thierfelder; L von Baumgarten; M Rottenkolber; F G Meinel; H Janssen; B Ertl-Wagner; M F Reiser; W H Sommer
Journal:  AJNR Am J Neuroradiol       Date:  2014-12-18       Impact factor: 3.825

3.  Wavelet-based calculation of cerebral angiographic data from time-resolved CT perfusion acquisitions.

Authors:  Lukas Havla; Kolja M Thierfelder; Sebastian E Beyer; Wieland H Sommer; Olaf Dietrich
Journal:  Eur Radiol       Date:  2015-02-26       Impact factor: 5.315

4.  Optimal scan timing for artery-vein separation at whole-brain CT angiography using a 320-row MDCT volume scanner.

Authors:  Takashi Shirasaka; Akio Hiwatashi; Koji Yamashita; Masatoshi Kondo; Hiroshi Hamasaki; Yamato Shimomiya; Yasuhiko Nakamura; Yoshinori Funama; Hiroshi Honda
Journal:  Br J Radiol       Date:  2016-12-20       Impact factor: 3.039

5.  Temporal averaging for analysis of four-dimensional whole-heart computed tomography perfusion of the myocardium: proof-of-concept study.

Authors:  S Feger; A Shaban; S Lukas; C Kendziorra; M Rief; E Zimmermann; M Dewey
Journal:  Int J Cardiovasc Imaging       Date:  2016-11-10       Impact factor: 2.357

6.  Detection of single-phase CTA occult vessel occlusions in acute ischemic stroke using CT perfusion-based wavelet-transformed angiography.

Authors:  Wolfgang G Kunz; Wieland H Sommer; Lukas Havla; Franziska Dorn; Felix G Meinel; Olaf Dietrich; Grete Buchholz; Birgit Ertl-Wagner; Kolja M Thierfelder
Journal:  Eur Radiol       Date:  2016-10-08       Impact factor: 5.315

7.  3D movement correction of CT brain perfusion image data of patients with acute ischemic stroke.

Authors:  Fahmi Fahmi; Henk A Marquering; Jordi Borst; Geert J Streekstra; Ludo F M Beenen; Joris M Niesten; Birgitta K Velthuis; Charles B L Majoie; Ed vanBavel
Journal:  Neuroradiology       Date:  2014-04-09       Impact factor: 2.804

8.  Validation of a method to differentiate arterial and venous vessels in CT perfusion data using linear combinations of quantitative time-density curve characteristics.

Authors:  Lukas Havla; Moritz Schneider; Kolja M Thierfelder; Sebastian E Beyer; Birgit Ertl-Wagner; Wieland H Sommer; Olaf Dietrich
Journal:  Eur Radiol       Date:  2015-03-28       Impact factor: 5.315

9.  Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

Authors:  Zebin Xiao; Yingyan Zheng; Jian Li; Dehua Chen; Fang Liu; Dairong Cao
Journal:  Dentomaxillofac Radiol       Date:  2017-10-10       Impact factor: 2.419

10.  4D CT angiography more closely defines intracranial thrombus burden than single-phase CT angiography.

Authors:  A M J Frölich; D Schrader; E Klotz; R Schramm; K Wasser; M Knauth; P Schramm
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-25       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.