Tracking target position variability using intraprostatic fiducial markers and electronic portal imaging in prostate cancer radiotherapy.

F Munoz1, C Fiandra, P Franco, A Guarneri, P Ciammella, P De Stefanis, N Rondi, F Moretto, S Badellino, C Iftode, R Ragona, U Ricardi.   

Abstract

PURPOSE: Modern radiotherapy has achieved substantial improvement in tumour control and toxicity rates by escalating the total dose to the target volume while sparing surrounding normal tissues. It has therefore become necessary to precisely track tumour position in order to minimise geometrical uncertainties due to setup errors and organ motion. We conducted this prospective evaluation of prostate cancer patients treated with image-guided conformal radiation therapy at our institution. We implanted three fiducial markers (gold seeds) within the prostatic gland in order to quantify daily target displacements and to generate specific margins around the clinical target volume (CTV) to create an appropriate planned target volume (PTV).
MATERIALS AND METHODS: Between April and December 2009, ten patients affected with localised prostate cancer were transrectally implanted with three radio-opaque markers. Each patient underwent a computed tomography (CT) scan for planning purposes following proper bladder and rectum preparation. During treatment two orthogonal images were acquired daily and compared with previously generated digitally reconstructed radiographs. After manual localisation, comparison between the position of the gold seeds on the portal and reference images was carried out, and a set of extrapolated lateral-lateral (LL), anterior-posterior (AP) and cranial-caudal (CC) shift corrections was calculated and recorded. Couch corrections were applied with a threshold of 3 mm displacement.
RESULTS: Systematic and random errors for each direction were calculated either as measured according to displacement of the gold seeds prior to any couch movement and after couch position correction according to the radio-opaque markers. For skin marks, mean systematic and random errors were 0.12+2.94 mm for LL, 1.04+3.37 mm for AP, -1.14+2.71 mm for CC, whereas for seed markers, mean and systematic errors were 0.6+1.5 mm for LL, 0.51+2.45 mm for AP and -0.25+2.51 mm for CC. A scatter plot generated on all measurements after couch repositioning according to gold-seed displacement suggested a confidence range of shift distributions within 5 mm for LL, 8 mm for CC, and 7 mm for AP. The total systematic and random components were then used to calculate proper PTV in patients receiving conventional treatment (7 mm for LL and 9 mm for both AP and CC).
CONCLUSIONS: Prostate positional variability during a course of radiation treatment is strongly influenced by setup and organ motion. Organ tracking through fiducial markers and electronic portal imaging is able to reduce the spread of displacements, significantly contributing to improve the ballistic precision of radiation delivery.

Entities:  

Mesh:

Year:  2012        PMID: 22327924     DOI: 10.1007/s11547-012-0797-7

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  25 in total

1.  Inclusion of geometric uncertainties in treatment plan evaluation.

Authors:  Marcel van Herk; Peter Remeijer; Joos V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-04-01       Impact factor: 7.038

Review 2.  Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy.

Authors:  Hiroki Shirato; Shinichi Shimizu; Kei Kitamura; Rikiya Onimaru
Journal:  Int J Clin Oncol       Date:  2007-02-25       Impact factor: 3.402

Review 3.  Advances in image-guided radiation therapy.

Authors:  Laura A Dawson; David A Jaffray
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

4.  A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer.

Authors:  J Lattanzi; S McNeeley; W Pinover; E Horwitz; I Das; T E Schultheiss; G E Hanks
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-03-01       Impact factor: 7.038

5.  Three-dimensional conformal radiation therapy in locally advanced carcinoma of the prostate: preliminary results of a phase I dose escalation study.

Authors:  T L Phillips
Journal:  Int J Radiat Oncol Biol Phys       Date:  1994-01-01       Impact factor: 7.038

Review 6.  The radiobiology of prostate cancer including new aspects of fractionated radiotherapy.

Authors:  Jack F Fowler
Journal:  Acta Oncol       Date:  2005       Impact factor: 4.089

7.  Cancer-specific mortality after surgery or radiation for patients with clinically localized prostate cancer managed during the prostate-specific antigen era.

Authors:  Anthony V D'Amico; Judd Moul; Peter R Carroll; Leon Sun; Deborah Lubeck; Ming-Hui Chen
Journal:  J Clin Oncol       Date:  2003-06-01       Impact factor: 44.544

8.  Prostate target volume variations during a course of radiotherapy.

Authors:  J A Antolak; I I Rosen; C H Childress; G K Zagars; A Pollack
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-10-01       Impact factor: 7.038

9.  Lateral rectal shielding reduces late rectal morbidity following high dose three-dimensional conformal radiation therapy for clinically localized prostate cancer: further evidence for a significant dose effect.

Authors:  W R Lee; G E Hanks; A L Hanlon; T E Schultheiss; M A Hunt
Journal:  Int J Radiat Oncol Biol Phys       Date:  1996-05-01       Impact factor: 7.038

10.  Potentials of on-line repositioning based on implanted fiducial markers and electronic portal imaging in prostate cancer radiotherapy.

Authors:  Reinhold Graf; Peter Wust; Volker Budach; Dirk Boehmer
Journal:  Radiat Oncol       Date:  2009-04-27       Impact factor: 3.481

View more
  4 in total

1.  Displacements of fiducial markers in patients with prostate cancer treated with image guided radiotherapy: A single-institution descriptive study.

Authors:  Ricardo Cendales; Felipe Torres; Juan Arbelaez; Armando Gaitan; Jaider Vasquez; Ivan Bobadilla
Journal:  Rep Pract Oncol Radiother       Date:  2014-09-01

Review 2.  A comparison of robotic arm versus gantry linear accelerator stereotactic body radiation therapy for prostate cancer.

Authors:  Vladimir Avkshtol; Yanqun Dong; Shelly B Hayes; Mark A Hallman; Robert A Price; Mark L Sobczak; Eric M Horwitz; Nicholas G Zaorsky
Journal:  Res Rep Urol       Date:  2016-08-18

3.  Impact of the observers' experience on daily prostate localization accuracy in ultrasound-based IGRT with the Clarity platform.

Authors:  Christian Fiandra; Alessia Guarneri; Fernando Muñoz; Francesco Moretto; Andrea Riccardo Filippi; Mario Levis; Riccardo Ragona; Umberto Ricardi
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

4.  Analysis of Geometric Shifts and Proper Setup-Margin in Prostate Cancer Patients Treated With Pelvic Intensity-Modulated Radiotherapy Using Endorectal Ballooning and Daily Enema for Prostate Immobilization.

Authors:  Songmi Jeong; Jong Hoon Lee; Mi Joo Chung; Sea Won Lee; Jeong Won Lee; Dae Gyu Kang; Sung Hwan Kim
Journal:  Medicine (Baltimore)       Date:  2016-01       Impact factor: 1.817