Mixing and matching causing taper wear: corrosion associated with pseudotumour formation.

R Chana1, C Esposito, P A Campbell, W K Walter, W L Walter.   

Abstract

We report a case of a male patient presenting with bilateral painful but apparently well-positioned and -fixed large-diameter metal-on-metal hip replacements four years post-operatively. Multiple imaging modes revealed a thick-walled, cystic expansile mass in communication with the hip joint (a pseudotumour). Implant retrieval analysis and tissue culture eliminated high bearing wear or infection as causes for the soft-tissue reaction, but noted marked corrosion of the modular neck taper adaptor and corrosion products in the tissues. Therefore, we believe corrosion products from the taper caused by mismatch of the implant components led to pseudotumour formation requiring revision.

Entities:  

Mesh:

Year:  2012        PMID: 22323701     DOI: 10.1302/0301-620X.94B2.27247

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  21 in total

1.  Taper design affects failure of large-head metal-on-metal total hip replacements.

Authors:  Nader A Nassif; Danyal H Nawabi; Kirsten Stoner; Marcella Elpers; Timothy Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

Review 2.  The surgical options and clinical evidence for treatment of wear or corrosion occurring with THA or TKA.

Authors:  Charles A Engh; Henry Ho; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

Review 3.  What is the trouble with trunnions?

Authors:  Christina I Esposito; Timothy M Wright; Stuart B Goodman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

4.  Does Taper Angle Clearance Influence Fretting and Corrosion Damage at the Head-Stem Interface? A Matched Cohort Retrieval Study.

Authors:  Sevi B Kocagöz; Richard J Underwood; Shiril Sivan; Jeremy L Gilbert; Daniel W Macdonald; Judd S Day; Steven M Kurtz
Journal:  Semin Arthroplasty       Date:  2013-12-01

Review 5.  Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

Authors:  Michael Morlock; Dennis Bünte; Julian Gührs; Nicholas Bishop
Journal:  HSS J       Date:  2016-09-20

6.  Ten year results of the collum femoris preserving total hip replacement: a prospective cohort study of seventy five patients.

Authors:  Jonathan Hutt; Ziad Harb; Ian Gill; Fadhil Kashif; John Miller; Matthew Dodd
Journal:  Int Orthop       Date:  2013-12-10       Impact factor: 3.075

7.  Aseptic hip pneumarthrosis following modular total hip arthroplasty: a potential mimic of hip infection.

Authors:  Yoav Morag; Corrie M Yablon; Alexander E Weber; Catherine Brandon; David J Blaha
Journal:  Emerg Radiol       Date:  2014-12-10

8.  What causes unexplained pain in patients with metal-on metal hip devices? A retrieval, histologic, and imaging analysis.

Authors:  Danyal H Nawabi; Nader A Nassif; Huong T Do; Kirsten Stoner; Marcella Elpers; Edwin P Su; Timothy Wright; Hollis G Potter; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

9.  Trunnionosis: the latest culprit in adverse reactions to metal debris following hip arthroplasty.

Authors:  Ryan M Shulman; Michael G Zywiel; Rajiv Gandhi; J Roderick Davey; David C Salonen
Journal:  Skeletal Radiol       Date:  2014-08-12       Impact factor: 2.199

10.  Does Surface Topography Play a Role in Taper Damage in Head-neck Modular Junctions?

Authors:  Robin Pourzal; Deborah J Hall; Nguyen Q Ha; Robert M Urban; Brett R Levine; Joshua J Jacobs; Hannah J Lundberg
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.