Stroke dynamics and frequency of 3 phacoemulsification machines.

Daniele Tognetto1, Paolo Cecchini, Pia Leon, Marta Di Nicola, Giuseppe Ravalico.   

Abstract

PURPOSE: To measure the working frequency and the stroke dynamics of the phaco tip of 3 phacoemulsification machines.
SETTING: University Eye Clinic of Trieste, Italy.
DESIGN: Experimental study.
METHODS: A video wet fixture was assembled to measure the working frequency using a micro camera and a micropulsed strobe-light system. A different video wet fixture was created to measure tip displacement as vectorial movement at different phaco powers using a microscopic video apparatus.
RESULTS: The working frequency of the Infiniti Ozil machine was 43.0 kHz in longitudinal mode and 31.6 kHz in torsional mode. The frequency of the Whitestar Signature machine was 29.0 kHz in longitudinal mode and 38.0 kHz with the Ellips FX handpiece. The Stellaris machine had a frequency of 28.8 kHz. The longitudinal stroke of the 3 machines at different phaco powers was statistically significantly different. The Stellaris machine had the highest stroke extent (139 μm). The lateral movement of the Infiniti Ozil and Whitestar Signature machines differed significantly. No movement on the y-axis was observed for the Infiniti Ozil machine in torsional mode. The elliptical path of the Ellips FX handpiece had different x and y components at different phaco powers.
CONCLUSIONS: The 3 phaco machines performed differently in terms of working frequency and stroke dynamics. The knowledge of the peculiar lateral and elliptical path strokes of Infiniti and Whitestar Signature machines may allow the surgeon to fully use these features for lens removal.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22322168     DOI: 10.1016/j.jcrs.2011.07.041

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Comparative clinical study of Whitestar Signature phacoemulsification system with standard and Ellips FX handpieces.

Authors:  Daniele Tognetto; Rossella D'Aloisio; Paolo Cecchini; Marta Di Nicola; Giuseppe Di Martino
Journal:  Int Ophthalmol       Date:  2017-07-13       Impact factor: 2.031

2.  Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines.

Authors:  Mustafa Ataş; Süleyman Demircan; Arzu Seyhan Karatepe Haşhaş; Ahmet Gülhan; Gökmen Zararsız
Journal:  Int J Ophthalmol       Date:  2014-10-18       Impact factor: 1.779

3.  A novel method to compare phacoemulsification parameters in vivo: two halves of one nucleus.

Authors:  Elena Tomilova; Sergey Shukhaev
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-06-21       Impact factor: 3.117

4.  Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision.

Authors:  Ahmed Assaf; Maged Maher Roshdy
Journal:  Clin Ophthalmol       Date:  2013-01-08

5.  Comparison of effective phacoemulsification time and corneal endothelial cell loss using three different ultrasound frequencies: A randomized controlled trial.

Authors:  Taru Dewan; Praveen K Malik; Preeti Tomar
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

6.  Transverse vs torsional ultrasound: prospective randomized contralaterally controlled study comparing two phacoemulsification-system handpieces.

Authors:  Kerry K Assil; Lindsay Harris; Jeannie Cecka
Journal:  Clin Ophthalmol       Date:  2015-08-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.