Abstract

This article presents a new method of cranioplasty in which polypropylene polyester knitwear was used as the filling material. The basis for prosthesis shaping was a three-dimensional model of the defect made according to the patient's CT scans. Previously, such material has never been a subject of computer-aided design and computer-aided manufacturing (CAD/CAM) individual forming. The process of the prosthesis design included CT bone scans and mold preparation for each patient. Such prostheses were implanted in 48 patients with cranial defects. The total number of prostheses applied was 51. The follow-up time was at least 6 months up to 36 months. The group of treated patients is described here, and sample pictures are shown to illustrate the results. The smallest defect had a size of 15 cm(2); the biggest, 178 cm(2). The coverage and the aesthetic results were very good in all cases. Two patients had postoperative complications. The cranioplastic solution described here is a valuable addition to the existing reconstructive methods, because of the low cost of the implant, the ease of its adjustment to the shape of the defect, and the short time of preparation.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22320208     DOI: 10.1089/neu.2011.2247

Source DB:  PubMed          Journal:  J Neurotrauma        ISSN: 0897-7151            Impact factor:   5.269


  5 in total

Review 1.  The Recent Revolution in the Design and Manufacture of Cranial Implants: Modern Advancements and Future Directions.

Authors:  David J Bonda; Sunil Manjila; Warren R Selman; David Dean
Journal:  Neurosurgery       Date:  2015-11       Impact factor: 4.654

2.  A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury.

Authors:  JingLe Jiang; Amar R Marathe; Jennifer C Keene; Dawn M Taylor
Journal:  J Neurosci Methods       Date:  2016-12-12       Impact factor: 2.390

3.  Cranioplasty with custom made alloplastic prosthetic implant: A case report.

Authors:  Lokendra Gupta; In Aparna; Dhanasekar Balakrishnan; Lingeshwar Deenadayalan; Puneeth Hegde; Priyanka Agarwal
Journal:  World J Clin Cases       Date:  2014-09-16       Impact factor: 1.337

Review 4.  Characterisation of Selected Materials in Medical Applications.

Authors:  Kacper Kroczek; Paweł Turek; Damian Mazur; Jacek Szczygielski; Damian Filip; Robert Brodowski; Krzysztof Balawender; Łukasz Przeszłowski; Bogumił Lewandowski; Stanisław Orkisz; Artur Mazur; Grzegorz Budzik; Józef Cebulski; Mariusz Oleksy
Journal:  Polymers (Basel)       Date:  2022-04-09       Impact factor: 4.967

5.  Comparison of two different titanium cranioplasty methods: Custom-made titanium prostheses versus precurved titanium mesh.

Authors:  Domenico Policicchio; Gina Casu; Giosuè Dipellegrini; Artan Doda; Giampiero Muggianu; Riccardo Boccaletti
Journal:  Surg Neurol Int       Date:  2020-06-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.