Literature DB >> 22313216

How successful are small-diameter implants? A literature review.

Keyvan Sohrabi1, Ammar Mushantat, Shahrokh Esfandiari, Jocelyne Feine.   

Abstract

BACKGROUND: Edentulism is an important issue and will remain so due to high numbers of edentate individuals worldwide. For many years, complete dentures have been the only treatment option for this population. Implant overdentures have been shown to have many advantages over conventional complete dentures. However, although dissatisfied with their mandibular dentures, some edentate elders are reluctant to undergo even simple implant treatment due to factors such as cost and fear of surgery. To address these obstacles, this paper reports on a review of small-diameter implant (SDI) studies that were performed in the last two decades. The aim of this study is to (i) determine the survival of narrow diameter implants, (ii) determine whether survival is dependent on whether these implants are placed using a flap or flapless approach, and (ii) determine whether there is a relationship between length and implant survival in SDIs.
METHODS: In this review, studies were included that (i) involve implants with 3.5 mm diameter or less, (ii) have a randomized clinical trial, retrospective or prospective cohort design with human subjects, (iii) provide a follow up duration of at least 5 months following implant placement, (iv) include data on the survival rate of the implants.
RESULTS: Forty one studies meeting the above criteria were published between 1993 and 2011 using SDIs from a variety of companies and surface characteristics with diameters of 1.8 mm to 3.5 mm and lengths of 8 mm to 18 mm. A total of 10,093 SDIs were inserted in approximately 2762 patients. Twenty-six studies involved flap reflection techniques for implant placement, six studies used a flapless technique and two studies used both techniques; in the remaining studies, the technique was not specified. Follow up duration varied from 5 months to over 9 years. The survival rate reported in all screened studies was over 90%, including eight studies in which a 100% survival rate was reported. In 22 studies, the reported survival rate ranged from 95% to 99.9%. Failure was reported most often in short SDIs (less than or equal 13 mm) (n = 88) compared to longer ones (more than 13 mm).
CONCLUSION: Survival rates reported for SDI are similar to those reported for standard width implants. These survival rates did not appear to differ between studies that used flapless and flap reflection techniques. The failure rate appeared to be higher in shorter SDIs than in longer ones in the studies in which the length of the failed implants was reported. SDIs could be considered for use with fixed restorations and mandibular overdentures, since their success rate appears to be comparable to that of regular diameter implants. They might also be an efficient, low-cost solution for elders who wish to reduce problems with denture instability.
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22313216     DOI: 10.1111/j.1600-0501.2011.02410.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  15 in total

Review 1.  Role of implant diameter on long-term survival of dental implants placed in posterior maxilla: a systematic review.

Authors:  Fawad Javed; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2014-11-01       Impact factor: 3.573

2.  Long-term implant success at the Academy for Oral Implantology: 8-year follow-up and risk factor analysis.

Authors:  Dieter Busenlechner; Rudolf Fürhauser; Robert Haas; Georg Watzek; Georg Mailath; Bernhard Pommer
Journal:  J Periodontal Implant Sci       Date:  2014-06-05       Impact factor: 2.614

3.  Success of dental implants in patients with large bone defect and analysis of risk factors for implant failure: a non-randomized retrospective cohort study.

Authors:  Takumi Hasegawa; Aki Sasaki; Izumi Saito; Satomi Arimoto; Nanae Yatagai; Yujiro Hiraoka; Daisuke Takeda; Yasumasa Kakei; Masaya Akashi
Journal:  Clin Oral Investig       Date:  2021-11-16       Impact factor: 3.573

4.  Immediate provisionalization in the esthetic zone: 1-year interim results from a prospective single-cohort multicenter study evaluating 3.0-mm-diameter tapered implants.

Authors:  Martin Kolinski; Pablo Hess; Sonia Leziy; Bertil Friberg; Gionata Bellucci; Davide Trisciuoglio; Wilfried Wagner; Maximilian Moergel; Alessandro Pozzi; Jörg Wiltfang; Eleonore Behrens; Werner Zechner; Christoph Vasak; Paul Weigl
Journal:  Clin Oral Investig       Date:  2018-02-03       Impact factor: 3.573

5.  A Novel Zirconia-Based Composite Presents an Aging Resistant Material for Narrow-Diameter Ceramic Implants.

Authors:  Felix Burkhardt; Markus Harlass; Erik Adolfsson; Kirstin Vach; Benedikt Christopher Spies; Ralf-Joachim Kohal
Journal:  Materials (Basel)       Date:  2021-04-23       Impact factor: 3.623

6.  Geriatric slim implants for complete denture wearers: clinical aspects and perspectives.

Authors:  Cedric Huard; Marion Bessadet; Emmanuel Nicolas; Jean-Luc Veyrune
Journal:  Clin Cosmet Investig Dent       Date:  2013-08-28

Review 7.  Narrow-diameter implants: are they a predictable treatment option? A literature review.

Authors:  José-Luis Sierra-Sánchez; Amparo Martínez-González; Fernando García-Sala Bonmatí; José-Félix Mañes-Ferrer; Alejandro Brotons-Oliver
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-01-01

8.  Narrow- versus mini-implants at crestal and subcrestal bone levels. Experimental study in beagle dogs at three months.

Authors:  José Luis Calvo-Guirado; Carlos Pérez-Albacete; Antonio Aguilar-Salvatierra; José E de Val Maté-Sánchez; Rafael A Delgado-Ruiz; Marcus Abboud; Eugenio Velasco; Gerardo Gómez-Moreno; Georgios E Romanos
Journal:  Clin Oral Investig       Date:  2014-12-11       Impact factor: 3.573

9.  Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlled trial.

Authors:  Frauke Müller; Bilal Al-Nawas; Stefano Storelli; Marc Quirynen; Stefan Hicklin; Jose Castro-Laza; Renzo Bassetti; Martin Schimmel
Journal:  BMC Oral Health       Date:  2015-10-12       Impact factor: 2.757

10.  Effects of Length and Inclination of Implants on Terminal Abutment Teeth and Implants in Mandibular CL1 Removable Partial Denture Assessed by Three-Dimensional Finite Element Analysis.

Authors:  Amir Fayaz; Alahyar Geramy; Yeganeh Memari; Zahra Rahmani
Journal:  J Dent (Tehran)       Date:  2015-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.