Literature DB >> 2230977

Biologically inert synthetic dural substitutes. Appraisal of a medical-grade aliphatic polyurethane and a polysiloxane-carbonate block copolymer.

D E Sakas1, K Charnvises, L F Borges, N T Zervas.   

Abstract

Two types of artificial membranes, a medical-grade aliphatic polyurethane and a polysiloxane-carbonate block copolymer, were tested as substitutes for dura in 24 and 12 rabbits, respectively. The films were placed either epidurally, subdurally, or as dural grafts in equal subgroups of animals. The postoperative course was uneventful with no manifestations of convulsive disorder or cerebrospinal fluid leak. The animals were sacrificed 3, 6, or 9 months after implantation of the artificial membranes. Both types of artificial membranes were easily removed from the underlying nervous and the other surrounding tissues. The histological examination failed to reveal adhesions, neomembrane formations, or any type of foreign body reactions to the polyurethane film. The implantation of the polysiloxane-carbonate film caused no reaction when it was applied epidurally. As a dural graft, the polysiloxane-carbonate copolymer induced the formation of a thin neomembrane of one to two layers of fibroblasts which formed a watertight seal of the dural defect. A similar thin neomembrane was found to encase this artificial membrane in the group of animals in which it was implanted subdurally. There was no foreign body reaction to the polysiloxane-carbonate film. The authors conclude that these materials hold promise as dural substitutes or in the prevention of spinal dural scarring, and should be evaluated clinically.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2230977     DOI: 10.3171/jns.1990.73.6.0936

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  11 in total

1.  Optical imaging of functional domains in the cortex of the awake and behaving monkey.

Authors:  N Vnek; B M Ramsden; C P Hung; P S Goldman-Rakic; A W Roe
Journal:  Proc Natl Acad Sci U S A       Date:  1999-03-30       Impact factor: 11.205

2.  Two-photon imaging of cerebral hemodynamics and neural activity in awake and anesthetized marmosets.

Authors:  Thom P Santisakultarm; Calvin J Kersbergen; Daryl K Bandy; David C Ide; Sang-Ho Choi; Afonso C Silva
Journal:  J Neurosci Methods       Date:  2016-07-05       Impact factor: 2.390

3.  Functional organization of temporal frequency selectivity in primate visual cortex.

Authors:  Ilya Khaytin; Xin Chen; David W Royal; Octavio Ruiz; Walter J Jermakowicz; Ralph M Siegel; Vivien A Casagrande
Journal:  Cereb Cortex       Date:  2007-12-03       Impact factor: 5.357

4.  Quantification of optical images of cortical responses for inferring functional maps.

Authors:  Gopathy Purushothaman; Ilya Khaytin; Vivien A Casagrande
Journal:  J Neurophysiol       Date:  2009-02-18       Impact factor: 2.714

5.  Principles of Intrinsic Motor Cortex Connectivity in Primates.

Authors:  Nicholas S Card; Omar A Gharbawie
Journal:  J Neurosci       Date:  2020-04-23       Impact factor: 6.167

6.  Absorbable Artificial Dura Versus Nonabsorbable Artificial Dura in Decompressive Craniectomy for Severe Traumatic Brain Injury: A Retrospective Cohort Study in Two Centers.

Authors:  Zhong-Ding Zhang; Li-Yan Zhao; Yi-Ru Liu; Jing-Yu Zhang; Shang-Hui Xie; Yan-Qi Lin; Zhuo-Ning Tang; Huang-Yi Fang; Yue Yang; Shi-Ze Li; Jian-Xi Liu; Han-Song Sheng
Journal:  Front Surg       Date:  2022-07-01

7.  Cortical connectivity is embedded in resting state at columnar resolution.

Authors:  Nicholas S Card; Omar A Gharbawie
Journal:  Prog Neurobiol       Date:  2022-03-12       Impact factor: 10.885

8.  Formulation and characterization of a porous, elastomeric biomaterial for vocal fold tissue engineering research.

Authors:  Joel Gaston; Rebecca S Bartlett; Sarah A Klemuk; Susan L Thibeault
Journal:  Ann Otol Rhinol Laryngol       Date:  2014-06-18       Impact factor: 1.547

9.  Two alternative dural sealing techniques in posterior fossa surgery: (Polylactide-co-glycolide) self-adhesive resorbable membrane versus polyethylene glycol hydrogel.

Authors:  Marco Schiariti; Francesco Acerbi; Morgan Broggi; Giovanni Tringali; Alberto Raggi; Giovanni Broggi; Paolo Ferroli
Journal:  Surg Neurol Int       Date:  2014-12-03

10.  Histological analysis of the repair of dural lesions with silicone mesh in rats subjected to experimental lesions.

Authors:  Fernando William Figueiredo da Rosa; Pedro Henrique Isoldi Pohl; Ana Maria Amaral Antônio Mader; Carla Peluso de Paiva; Aline Amaro dos Santos; Bianca Bianco; Luciano Miller Reis Rodrigues
Journal:  Einstein (Sao Paulo)       Date:  2015 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.