OBJECTIVE: To evaluate folding in infrarenal stent grafts in relation to oversizing, barb angle, and barb length using computed tomography images of stent grafts deployed in explanted bovine aortas. METHODS: Computed tomography data from an in vitro investigation on the effect of oversizing of 4% to 45% (n = 19), barb length of 2 to 7 mm (n = 11), and barb angle of 10° to 90° (n = 7) on device fixation were examined for instances of folding. Folding was classified as circumferential or longitudinal and quantified on an ordinal scale based on codified criteria. Cumulative fold ranking from 0 (no fold) to 6 (two severe folds) for each deployment was used as the measure of folding observed. RESULTS: Of the 37 cases, cumulative mean ± standard deviation fold ranking for stent grafts oversized >30% (n = 5) was significantly greater than the rest (3.4 ± 1.7 vs 0.5 ± 1.2, respectively; Mann-Whitney U test; P < .005). When barb length was varied from 2 to 7 mm (oversizing held at 10%-20%), folding was noted in one of 11 cases. Similarly, when barb angle was varied from 0° (vertical) to 90° (horizontal), folding was not noted in any of the seven cases. The pullout force was not significantly different between stent grafts with and without folding (5.4 ± 1.95 vs 5.12 ± 1.89 N, respectively; P > .5). At least one instance of folding was noted in the seven of seven (100%) stent grafts with oversizing >23.5% and in only five of 30 (14%) stent grafts with oversizing <23.5%. CONCLUSIONS: Stent graft folding was prevalent when oversized >30%. Large variations in barb length and angle did not aggravate folding risk when oversized within the recommended range of 10% to 20%.
OBJECTIVE: To evaluate folding in infrarenal stent grafts in relation to oversizing, barb angle, and barb length using computed tomography images of stent grafts deployed in explanted bovine aortas. METHODS: Computed tomography data from an in vitro investigation on the effect of oversizing of 4% to 45% (n = 19), barb length of 2 to 7 mm (n = 11), and barb angle of 10° to 90° (n = 7) on device fixation were examined for instances of folding. Folding was classified as circumferential or longitudinal and quantified on an ordinal scale based on codified criteria. Cumulative fold ranking from 0 (no fold) to 6 (two severe folds) for each deployment was used as the measure of folding observed. RESULTS: Of the 37 cases, cumulative mean ± standard deviation fold ranking for stent grafts oversized >30% (n = 5) was significantly greater than the rest (3.4 ± 1.7 vs 0.5 ± 1.2, respectively; Mann-Whitney U test; P < .005). When barb length was varied from 2 to 7 mm (oversizing held at 10%-20%), folding was noted in one of 11 cases. Similarly, when barb angle was varied from 0° (vertical) to 90° (horizontal), folding was not noted in any of the seven cases. The pullout force was not significantly different between stent grafts with and without folding (5.4 ± 1.95 vs 5.12 ± 1.89 N, respectively; P > .5). At least one instance of folding was noted in the seven of seven (100%) stent grafts with oversizing >23.5% and in only five of 30 (14%) stent grafts with oversizing <23.5%. CONCLUSIONS: Stent graft folding was prevalent when oversized >30%. Large variations in barb length and angle did not aggravate folding risk when oversized within the recommended range of 10% to 20%.
Authors: Christopher K Zarins; Daniel A Bloch; Tami Crabtree; Alan H Matsumoto; Rodney A White; Thomas J Fogarty Journal: J Vasc Surg Date: 2003-12 Impact factor: 4.268
Authors: Marina Piccinelli; Alessandro Veneziani; David A Steinman; Andrea Remuzzi; Luca Antiga Journal: IEEE Trans Med Imaging Date: 2009-05-12 Impact factor: 10.048
Authors: Frederik H W Jonker; Felix J V Schlosser; Arnar Geirsson; Bauer E Sumpio; Frans L Moll; Bart E Muhs Journal: J Endovasc Ther Date: 2010-12 Impact factor: 3.487
Authors: J van Prehn; F J V Schlösser; B E Muhs; H J M Verhagen; F L Moll; J A van Herwaarden Journal: Eur J Vasc Endovasc Surg Date: 2009-05-09 Impact factor: 7.069
Authors: Irwin V Mohan; Peter L Harris; Corine J Van Marrewijk; Robert J Laheij; Thien V How Journal: J Endovasc Ther Date: 2002-12 Impact factor: 3.487
Authors: Michael S Conners; W Charles Sternbergh; Glen Carter; Britt H Tonnessen; Moises Yoselevitz; Samuel R Money Journal: J Vasc Surg Date: 2002-09 Impact factor: 4.268
Authors: Guido H W van Bogerijen; Jip L Tolenaar; Michele Conti; Ferdinando Auricchio; Francesco Secchi; Francesco Sardanelli; Frans L Moll; Joost A van Herwaarden; Vincenzo Rampoldi; Santi Trimarchi Journal: Aorta (Stamford) Date: 2013-08-01