Literature DB >> 2230301

Validation of a new automatic system for biplane quantitative coronary arteriography.

M Büchi1, O M Hess, R L Kirkeeide, T Suter, M Muser, H P Osenberg, P Niederer, M Anliker, K L Gould, H P Krayenbühl.   

Abstract

In a collaboration between the University of Texas (software) and the University of Zürich (hardware) a compact, automatic system for biplane quantitative coronary arteriography was developed. The system is based on a 35 mm film projector, a slow-scan CCD-camera (image digitizing) and a computer workstation (Apollo DN 3000, image storage and processing). A new calibration procedure based on two fixed reference points in the center of the image intensifier was used (isocenter technique). Contour detection of coronary arteries was carried out in biplane projection using a geometric-densitometric edge-detection algorithm. The proximal and distal luminal areas, as well as the minimal luminal area of the stenotic vessel segment were determined. Accuracy and precision were determined from precision drilled holes in a plexiglas cube which were filled with 50%, 75% and 100% contrast medium. The diameter of the holes ranged from 0.5 to 5.0 mm. The mean difference and the standard deviation of the differences between the true and the measured diameters were 0.12 +/- 0.14 mm for plane A and 0.26 +/- 0.17 mm for plane B, respectively. After a second order correction the mean difference amounted to 0.02 +/- 0.09 mm for plane A and 0.02 +/- 0.12 mm for plane B, respectively. Intra- and interobserver variability were evaluated in 5 patients (age 60 +/- 10 years) with coronary artery disease using 16 normal and 5 stenotic vessel segments (cross-sectional area ranging from 0.8 to 8.7 mm2). Two independent observers analyzed the same vessel segment twice. Intraobserver variability expressed as the standard error of estimate in percent of the mean angiographic vessel area (SEE) amounted to 2.1% for observer 1 and 4.4% for observer 2, respectively. Interobserver variability expressed as SEE was 4.1% for measurement 1 and 3.6% for measurement 2, respectively.

Entities:  

Mesh:

Year:  1990        PMID: 2230301     DOI: 10.1007/bf01833978

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  8 in total

1.  Vasoconstriction of stenotic coronary arteries during dynamic exercise in patients with classic angina pectoris: reversibility by nitroglycerin.

Authors:  J E Gage; O M Hess; T Murakami; M Ritter; J Grimm; H P Krayenbuehl
Journal:  Circulation       Date:  1986-05       Impact factor: 29.690

2.  Mathematical tools for spatial computations with biplane isocentric X-ray equipment.

Authors:  H Wollschläger; P Lee; A Zeiher; U Solzbach; T Bonzel; H Just
Journal:  Biomed Tech (Berl)       Date:  1986-05       Impact factor: 1.411

3.  Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.

Authors:  J H Reiber; P W Serruys; C J Kooijman; W Wijns; C J Slager; J J Gerbrands; J C Schuurbiers; A den Boer; P G Hugenholtz
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

4.  Is there coronary vasoconstriction after intracoronary beta-adrenergic blockade in patients with coronary artery disease.

Authors:  A Gaglione; O M Hess; W J Corin; M Ritter; J Grimm; H P Krayenbuehl
Journal:  J Am Coll Cardiol       Date:  1987-08       Impact factor: 24.094

5.  Left ventricular border recognition using a dynamic search algorithm.

Authors:  D L Pope; D L Parker; P D Clayton; D E Gustafson
Journal:  Radiology       Date:  1985-05       Impact factor: 11.105

6.  Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms.

Authors:  J R Spears; T Sandor; A V Als; M Malagold; J E Markis; W Grossman; J R Serur; S Paulin
Journal:  Circulation       Date:  1983-08       Impact factor: 29.690

7.  Cine-densitometric measurement of coronary arterial stenoses.

Authors:  T Sandor; A V Als; S Paulin
Journal:  Cathet Cardiovasc Diagn       Date:  1979

8.  Quantitative coronary arteriography: estimation of dimensions, hemodynamic resistance, and atheroma mass of coronary artery lesions using the arteriogram and digital computation.

Authors:  B G Brown; E Bolson; M Frimer; H T Dodge
Journal:  Circulation       Date:  1977-02       Impact factor: 29.690

  8 in total
  4 in total

Review 1.  Biplane X-ray angiograms, intravascular ultrasound, and 3D visualization of coronary vessels.

Authors:  K R Hoffmann; A Wahle; C Pellot-Barakat; J Sklansky; M Sonka
Journal:  Int J Card Imaging       Date:  1999-12

2.  A system for determination of 3D vessel tree centerlines from biplane images.

Authors:  K R Hoffmann; A Sen; L Lan; K G Chua; J Esthappan; M Mazzucco
Journal:  Int J Card Imaging       Date:  2000-10

3.  Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound.

Authors:  G P Prause; S C DeJong; C R McKay; M Sonka
Journal:  Int J Card Imaging       Date:  1997-12

4.  The impact of vessel and catheter position on the measurement accuracy in catheter-based quantitative coronary angiography.

Authors:  W Wunderlich; B Roehrig; F Fischer; H R Arntz; R Agrawal; A Morguet; H P Schultheiss; D Horstkotte
Journal:  Int J Card Imaging       Date:  1998-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.