Literature DB >> 6861322

Computerized image analysis for quantitative measurement of vessel diameter from cineangiograms.

J R Spears, T Sandor, A V Als, M Malagold, J E Markis, W Grossman, J R Serur, S Paulin.   

Abstract

Subjective estimates of the angiographic severity of coronary artery stenoses show variability and inaccuracy. We therefore tested the accuracy of a newly developed computerized image analysis system for quantitating vessel diameter from cineangiograms. Fourteen cylindrical phantoms of known diameter were filled with contrast medium and filmed over a wide range of clinically relevant radiographic conditions in order to develop regression equations that related computer-derived to anatomic diameters. Computer measurements of vessel diameter were unaffected by vessel size, magnification, focal spot size, thickness of scattering medium, kilovolt peak, or location within the radiographic field, but a correction factor was necessary for a small but significant (p less than .01) linear dependence on contrast medium concentration. The accuracy of computerized vessel diameter measurements ranged between +/- 59 and +/- 137 mu for all conditions except for rapid vessel motion and contrast medium concentrations of 50% or less meglumine diatrizoate (Renografin 76), both of which resulted in reduced accuracy as well as in the inability to locate lumen edges of vessels less than 1 mm in diameter.

Entities:  

Mesh:

Year:  1983        PMID: 6861322     DOI: 10.1161/01.cir.68.2.453

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  22 in total

1.  Comparison of digital and cine coronary arteriography.

Authors:  J C Gurley; S E Nissen
Journal:  Int J Card Imaging       Date:  1990

2.  3D-reconstruction of coronary arteries in view of flow measurement.

Authors:  N Guggenheim; F Chappuis; C Suilen; P A Doriot; P A Dorsaz; P Descouts; W Rutishauser
Journal:  Int J Card Imaging       Date:  1992

3.  Effects of video frame averaging, smoothing and edge enhancement on the accuracy and precision of quantitative coronary arteriography.

Authors:  K M Kavanaugh; I M Pinto; M J McGillem; S F DeBoe; G B Mancini
Journal:  Int J Card Imaging       Date:  1990

4.  Validation of a new automatic system for biplane quantitative coronary arteriography.

Authors:  M Büchi; O M Hess; R L Kirkeeide; T Suter; M Muser; H P Osenberg; P Niederer; M Anliker; K L Gould; H P Krayenbühl
Journal:  Int J Card Imaging       Date:  1990

5.  Clinical percutaneous imaging of coronary anatomy using an over-the-wire ultrasound catheter system.

Authors:  J M Hodgson; S P Graham; A D Savakus; S G Dame; D N Stephens; P S Dhillon; D Brands; H Sheehan; M J Eberle
Journal:  Int J Card Imaging       Date:  1989

6.  Features of the angiographic evaluation of the INTACT study. International Nifedipine Trial on Antiatherosclerotic Therapy.

Authors:  S Jost; J Deckers; W Rafflenbeul; H Hecker; U Nellessen; B Wiese; P G Hugenholtz; P R Lichtlen
Journal:  Cardiovasc Drugs Ther       Date:  1990-08       Impact factor: 3.727

Review 7.  Novel QCA methodologies and angiographic scores.

Authors:  Vivian G Ng; Alexandra J Lansky
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-20       Impact factor: 2.357

8.  Automatic detection method of stenotic lesions in coronary cineangiograms.

Authors:  T Sugahara; H Maeda; Y Yanagihara
Journal:  Int J Card Imaging       Date:  1989

9.  Non-invasive measurement of human endothelium dependent arterial responses: accuracy and reproducibility.

Authors:  K E Sorensen; D S Celermajer; D J Spiegelhalter; D Georgakopoulos; J Robinson; O Thomas; J E Deanfield
Journal:  Br Heart J       Date:  1995-09

10.  In vivo detection of endothelium dependent and independent pulmonary artery relaxation in children.

Authors:  D S Celermajer; S Cullen; J E Deanfield
Journal:  Br Heart J       Date:  1993-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.