Harmonic reduction in capacitive micromachined ultrasonic transducers by gap feedback linearization.

Sarp Satir1, F Levent Degertekin.   

Abstract

The nonlinear relationship between the electrical input signal and electrostatic force acting on the capacitive micromachined ultrasonic transducer (CMUT) membrane limits its harmonic imaging performance. Several input shaping methods were proposed to compensate for the nonlinearity originating from the electrostatic force's dependence on the square of the applied voltage. Here, we analyze harmonic generation in CMUTs with a time-domain model. The model explains the basis of the input shaping methods and suggests that the nonlinearity resulting from gap dependence of the electrostatic force is also significant. It also suggests that the harmonic distortion in the output pressure can be eliminated by subharmonic ac-only excitation of the CMUT in addition to scaling the input voltage with the instantaneous gap. This gap feedback configuration can be approximated by the simple addition of a series impedance to the CMUT capacitance. We analyze several types of series impedance feedback topologies for gap feedback linearization. We show that for subharmonic ac excitation, although resistive and capacitive impedances result in a trade-off between input voltage and harmonic distortion for a desired pressure output, harmonic generation can be suppressed while increasing the Pa/V transmit sensitivity for proper series inductance and resistance feedback. We experimentally demonstrate the feedback method by reducing harmonic generation by 10 dB for the same output pressure at the fundamental frequency by using a simple series resistor feedback with a CMUT operating at a center frequency of 3 MHz. The proposed methods also allow for utilization of the full CMUT gap for transmit operation and, hence, should be useful in high-intensity ultrasonic applications in addition to harmonic imaging.
© 2012 IEEE

Entities:  

Mesh:

Year:  2012        PMID: 22293735      PMCID: PMC3369142          DOI: 10.1109/TUFFC.2012.2155

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  7 in total

1.  Precompensated excitation waveforms to suppress harmonic generation in MEMS electrostatic transducers.

Authors:  Shiwei Zhou; Paul Reynolds; John Hossack
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-11       Impact factor: 2.725

2.  Linear and nonlinear equivalent circuit modeling of CMUTs.

Authors:  Annette Lohfink; Peter-Christian Eccardt
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

3.  CMUTS with dual-electrode structure for improved transmit and receive performance.

Authors:  Rasim O Guldiken; Jeff McLean; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-02       Impact factor: 2.725

4.  Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents.

Authors:  D H Simpson; C T Chin; P N Burns
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

5.  Third harmonic transmit phasing for tissue harmonic generation.

Authors:  Che-Chou Shen; Yu-Chun Wang; Yi-Chun Hsieh
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-07       Impact factor: 2.725

6.  Exploitation of capacitive micromachined transducers for nonlinear ultrasound imaging.

Authors:  Anthony Novell; Mathieu Legros; Nicolas Felix; Ayache Bouakaz
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-12       Impact factor: 2.725

7.  Surface micromachined capacitive ultrasonic transducers.

Authors:  I Ladabaum; X Jin; H T Soh; A Atalar; B T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

  7 in total
  9 in total

1.  A nonlinear lumped model for ultrasound systems using CMUT arrays.

Authors:  Sarp Satir; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-10       Impact factor: 2.725

2.  Phase and Amplitude Modulation Methods for Nonlinear Ultrasound Imaging With CMUTs.

Authors:  Sarp Satir; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-04-21       Impact factor: 2.725

3.  Wideband acoustic activation and detection of droplet vaporization events using a capacitive micromachined ultrasonic transducer.

Authors:  Anthony Novell; Christopher B Arena; Omer Oralkan; Paul A Dayton
Journal:  J Acoust Soc Am       Date:  2016-06       Impact factor: 1.840

4.  An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography.

Authors:  Marzana Mantasha Mahmud; Xun Wu; Jean Lunsford Sanders; Ali Onder Biliroglu; Oluwafemi Joel Adelegan; Isabel G Newsome; Feysel Yalcin Yamaner; Paul A Dayton; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-09       Impact factor: 2.725

5.  Highly Integrated Guidewire Ultrasound Imaging System-on-a-Chip.

Authors:  Jaemyung Lim; Coskun Tekes; Evren F Arkan; Ahmad Rezvanitabar; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE J Solid-State Circuits       Date:  2020-01-30       Impact factor: 5.013

6.  A large-signal model for CMUT arrays with arbitrary membrane geometry operating in non-collapsed mode.

Authors:  Sarp Satir; Jaime Zahorian; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-11       Impact factor: 2.725

7.  Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array.

Authors:  Anthony Novell; Christopher B Arena; Sandeep Kasoji; Paul A Dayton
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

8.  Supply-Inverted Bipolar Pulser and Tx/Rx Switch for CMUTs Above the Process Limit for High Pressure Pulse Generation.

Authors:  Gwangrok Jung; Amirabbas Pirouz; Coskun Tekes; Thomas M Carpenter; David Cowell; Steven Freear; Maysam Ghovanloo; F Levent Degertekin
Journal:  IEEE Sens J       Date:  2019-08-28       Impact factor: 3.301

9.  Supply-Doubled Pulse-Shaping High Voltage Pulser for CMUT Arrays.

Authors:  Gwangrok Jung; Coskun Tekes; Amirabbas Pirouz; F Levent Degertekin; Maysam Ghovanloo
Journal:  IEEE Trans Circuits Syst II Express Briefs       Date:  2017-04-06       Impact factor: 3.292

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.