Literature DB >> 20040410

Exploitation of capacitive micromachined transducers for nonlinear ultrasound imaging.

Anthony Novell1, Mathieu Legros, Nicolas Felix, Ayache Bouakaz.   

Abstract

Capacitive micromachined ultrasonic transducers (CMUTs) present advantages such as wide frequency bandwidth, which could be further developed for nonlinear imaging. However, the driving electrostatic force induces a nonlinear behavior of the CMUT, thus generating undesirable harmonic components in the generated acoustic signal. Consequently, the use of CMUT for harmonic imaging (with or without contrast agents) becomes challenging. This paper suggests 2 compensation approaches, linear and nonlinear methods, to cancel unwanted nonlinear components. Furthermore, nonlinear responses from contrast agent were evaluated using CMUT in transmit before and after compensation. The results were compared with those obtained using a PZT transducer in transmit. Results showed that CMUT nonlinear behavior is highly influenced by the excitation to bias voltage ratio. Measurements of output pressure very close to the CMUT surface allow the estimation of optimal parameters for each compensation approach. Both methods showed a harmonic reduction higher than 20 dB when one element or several elements are excited. In addition, the study demonstrates that nonlinear approach seems to be more efficient because it is shown to be less sensitive to interelement variability and further avoids fundamental component deterioration. The results from contrast agent measurements showed that the responses obtained using CMUT elements in transmit with compensation were similar to those from PZT transducer excitation. This experimental study demonstrates the opportunity to use CMUT with traditional harmonic contrast imaging techniques.

Entities:  

Mesh:

Year:  2009        PMID: 20040410     DOI: 10.1109/TUFFC.2009.1364

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  7 in total

1.  Harmonic reduction in capacitive micromachined ultrasonic transducers by gap feedback linearization.

Authors:  Sarp Satir; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-01       Impact factor: 2.725

2.  Phase and Amplitude Modulation Methods for Nonlinear Ultrasound Imaging With CMUTs.

Authors:  Sarp Satir; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-04-21       Impact factor: 2.725

3.  Wideband acoustic activation and detection of droplet vaporization events using a capacitive micromachined ultrasonic transducer.

Authors:  Anthony Novell; Christopher B Arena; Omer Oralkan; Paul A Dayton
Journal:  J Acoust Soc Am       Date:  2016-06       Impact factor: 1.840

4.  An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography.

Authors:  Marzana Mantasha Mahmud; Xun Wu; Jean Lunsford Sanders; Ali Onder Biliroglu; Oluwafemi Joel Adelegan; Isabel G Newsome; Feysel Yalcin Yamaner; Paul A Dayton; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-09       Impact factor: 2.725

5.  Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer.

Authors:  Brooks D Lindsey; Jinwook Kim; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-05-08       Impact factor: 2.725

6.  Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array.

Authors:  Anthony Novell; Christopher B Arena; Sandeep Kasoji; Paul A Dayton
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

7.  Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging.

Authors:  K Heath Martin; Brooks D Lindsey; Jianguo Ma; Mike Lee; Sibo Li; F Stuart Foster; Xiaoning Jiang; Paul A Dayton
Journal:  Sensors (Basel)       Date:  2014-11-04       Impact factor: 3.576

  7 in total