Literature DB >> 22291055

Fast and universal HPLC method for determination of permethrin in formulations using 1.8-μm particle-packed column and performance comparison with other column types.

Maja A Shishovska1, Marina T Stefova.   

Abstract

An HPLC method has been developed for the fast separation and quantification of permethrin using C18 column packed with 1.8 µm particles. The method is specific with good resolution to degradation products and to other present components. It has acceptable validation results. The run time is 4.5 min (or may be within 1.6 min is rapid resolution mode) with an organic solvent consumption of 3.6 mL per run. The method has been applied to samples of formulations for various uses: mattress cleaner, shampoo, and veterinary powder. The performance of the applied column is compared with other common column types. The relationships between linear velocity of the mobile phase (u) and resolution factor (Rs), back-pressure (ΔP), and efficiency (H) are presented. The experimental data shows the advantages of 1.8-µm particle columns to be a significant reduction in solvent consumption (by factor of 4.4 and 1.5) and a reduction in run-time (by factor 4.7 and 1.5), and the weaknesses are a high back-pressure and lower efficiency. Finally, it has been shown that use of 1.8-µm particle packed columns with conventional HPLC systems is possible, but with limitations in mobile phase flow-rate.
© The Author [2011]. Published by Oxford University Press. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22291055      PMCID: PMC3252127          DOI: 10.1093/chromsci/bmr014

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  22 in total

1.  Comparison of the performance of conventional microparticulates and monolithic reversed-phase columns for liquid chromatography separation of eleven pollutant phenols.

Authors:  M Cledera-Castro; A Santos-Montes; R Izquierdo-Hornillos
Journal:  J Chromatogr A       Date:  2005-09-16       Impact factor: 4.759

2.  High-speed analyses using rapid resolution liquid chromatography on 1.8-microm porous particles.

Authors:  Tatsunari Yoshida; Ronald E Majors
Journal:  J Sep Sci       Date:  2006-11       Impact factor: 3.645

3.  Domain size-induced heterogeneity as performance limitation of small-domain monolithic columns and other LC support types.

Authors:  Jeroen Billen; Piotr Gzil; Gert Desmet
Journal:  Anal Chem       Date:  2006-09-01       Impact factor: 6.986

Review 4.  About the C term in the van Deemter's equation of plate height in monoliths.

Authors:  A-M Siouffi
Journal:  J Chromatogr A       Date:  2006-06-23       Impact factor: 4.759

Review 5.  Monolithic columns in high-performance liquid chromatography.

Authors:  Georges Guiochon
Journal:  J Chromatogr A       Date:  2007-06-03       Impact factor: 4.759

6.  Mass transfer kinetic mechanism in monolithic columns and application to the characterization of new research monolithic samples with different average pore sizes.

Authors:  Fabrice Gritti; Georges Guiochon
Journal:  J Chromatogr A       Date:  2009-04-16       Impact factor: 4.759

7.  Rapid analysis of pyrethroids in whole urine by high-performance liquid chromatography using a monolithic column and off-line preconcentration in a restricted access material cartridge.

Authors:  M E León-González; M Plaza-Arroyo; L V Pérez-Arribas; L M Polo-Díez
Journal:  Anal Bioanal Chem       Date:  2005-02-18       Impact factor: 4.142

8.  Separation and aquatic toxicity of enantiomers of synthetic pyrethroid insecticides.

Authors:  Weiping Liu; Jay J Gan; Sujie Qin
Journal:  Chirality       Date:  2005       Impact factor: 2.437

9.  Fast HPLC for quality control of Harpagophytum procumbens by using a monolithic silica column: method transfer from conventional particle-based silica column.

Authors:  Alexander H Schmidt
Journal:  J Chromatogr A       Date:  2005-05-06       Impact factor: 4.759

10.  The performance of hybrid monolithic silica capillary columns prepared by changing feed ratios of tetramethoxysilane and methyltrimethoxysilane.

Authors:  Takeshi Hara; Satoshi Makino; Yuta Watanabe; Tohru Ikegami; Karin Cabrera; Bernd Smarsly; Nobuo Tanaka
Journal:  J Chromatogr A       Date:  2009-11-10       Impact factor: 4.759

View more
  2 in total

1.  Improvement of an Automated Sample Injection System for Pillar Array Columns to Increase Analytical Reproducibility.

Authors:  Hiroshi Kuroki; Hirotaka Koyama; Makoto Tsunoda
Journal:  Molecules       Date:  2022-07-23       Impact factor: 4.927

2.  A simple protocol for determination of enantiopurity of amines using BINOL derivatives as chiral solvating agents via 1H- and 19F-NMR spectroscopic analysis.

Authors:  Pooja Chaudhary; Geeta Devi Yadav; Surendra Singh
Journal:  RSC Adv       Date:  2022-09-08       Impact factor: 4.036

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.