Literature DB >> 22267587

Comparison of three-dimensional isotropic T1-weighted fast spin-echo MR arthrography with two-dimensional MR arthrography of the shoulder.

Hye Jung Choo1, Sun Joo Lee, Ok-Hwoa Kim, Seung Suk Seo, Jung Han Kim.   

Abstract

PURPOSE: To determine the accuracy of a three-dimensional (3D) isotropic T1-weighted fast spin-echo (FSE) magnetic resonance (MR) sequence as compared with a conventional two-dimensional (2D) sequence in the diagnosis of rotator cuff tears and labral lesions.
MATERIALS AND METHODS: Institutional review board approval was obtained, and the informed consent requirement was waived. Forty-nine patients who had undergone direct or indirect shoulder MR arthrography with the 2D T1-weighted FSE sequence and the 3D isotropic T1-weighted FSE sequence and subsequent arthroscopy were included. Each MR imaging sequence was independently scored by two readers retrospectively for the presence of full- or partial-thickness tears of the supraspinatus (SST) and infraspinatus (IST) tendons and the subscapularis tendon (SCT) and labral lesions. Diagnostic performance based on each sequence type was compared by using the area under the receiver operating characteristic curve (AUC).
RESULTS: Arthroscopic findings enabled confirmation of the presence of 17 full-thickness SST-IST tears, 18 partial-thickness SST-IST tears, four full-thickness SCT tears, 17 partial-thickness SCT tears, and 17 labral lesions. The AUCs for the readers using the 3D T1-weighted FSE sequence versus those obtained with the 2D sequence were 0.771-0.989 versus 0.837-0.998 for reader A and 0.771-0.989 versus 0.797-0.989 for reader B in the detection of rotator cuff tears and 0.885 versus 0.897 for reader A and 0.895 versus 0.895 for reader B in the detection of labral lesions. The mean AUCs between the 2D and 3D sequences were not significantly different, with the exception of partial-thickness SCT tears for one reader.
CONCLUSION: The accuracy of 3D isotropic FSE MR arthrography may be comparable with that of conventional 2D MR arthrography in the diagnosis of rotator cuff tears and labral lesions with a shorter imaging time. © RSNA, 2012.

Entities:  

Mesh:

Year:  2012        PMID: 22267587     DOI: 10.1148/radiol.11111261

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  20 in total

1.  The usefulness of the three-dimensional enhanced T1 high-resolution isotropic volume excitation MR in the evaluation of shoulder pathology: comparison with two-dimensional enhanced T1 fat saturation MR.

Authors:  Hee J Park; So Y Lee; Myung H Rho; Heon J Kwon; Mi S Kim; Eun C Chung
Journal:  Br J Radiol       Date:  2015-08-05       Impact factor: 3.039

Review 2.  Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis.

Authors:  Ciaran McGarvey; Ziad Harb; Christian Smith; Russell Houghton; Steven Corbett; Adil Ajuied
Journal:  Skeletal Radiol       Date:  2015-12-03       Impact factor: 2.199

3.  Diagnostic performance of wrist magnetic resonance (MR) arthrography: comparison of three-dimensional isotropic T1 weighted fast spin-echo MR arthrography and two-dimensional MR arthrography.

Authors:  Eunsun Oh; Young C Yoon; Min J Park
Journal:  Br J Radiol       Date:  2017-02-15       Impact factor: 3.039

4.  MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.

Authors:  Giovanni Foti; Paolo Avanzi; William Mantovani; Flavia Dal Corso; Emanuele Demozzi; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

5.  SLAP tears: diagnosis using 3-T shoulder MR arthrography with the 3D isotropic turbo spin-echo space sequence versus conventional 2D sequences.

Authors:  Joon-Yong Jung; Won-Hee Jee; Michael Yong Park; So-Yeon Lee; Yang-Soo Kim
Journal:  Eur Radiol       Date:  2012-08-04       Impact factor: 5.315

6.  MRI of the anterior talofibular ligament, talar cartilage and os subfibulare: Comparison of isotropic resolution 3D and conventional 2D T2-weighted fast spin-echo sequences at 3.0 T.

Authors:  Jisook Yi; Jang Gyu Cha; Young Koo Lee; Bo Ra Lee; Chan Hong Jeon
Journal:  Skeletal Radiol       Date:  2016-03-19       Impact factor: 2.199

7.  Diagnostic Performance of MR Arthrography with Anterior Trans-Subscapularis versus Posterior Injection Approach for Subscapularis Tendon Tears at 3.0T.

Authors:  Joon-Yong Jung; Won-Hee Jee; Chang-Woo Chun; Yang-Soo Kim
Journal:  Eur Radiol       Date:  2016-06-16       Impact factor: 5.315

8.  Evaluation of glenoid labral tears: comparison between dual-energy CT arthrography and MR arthrography of the shoulder.

Authors:  Giovanni Foti; William Mantovani; Matteo Catania; Paolo Avanzi; Simone Caia; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2019-09-20       Impact factor: 3.469

9.  Diagnostic accuracy of ultrasound in subscapularis tendon abnormalities and the importance of operator experience.

Authors:  Uğur Toprak; Sefa Türkoğlu; Çiğdem Aydoğan; Emrah Kovalak; Suzan Saylısoy; Duygu Sıddıkoğlu; Akkan Mahmud
Journal:  Acta Orthop Traumatol Turc       Date:  2020-07       Impact factor: 1.511

10.  Evaluation of shoulder pathology: three-dimensional enhanced T1 high-resolution isotropic volume excitation MR vs two-dimensional fast spin echo T2 fat saturation MR.

Authors:  H J Park; S Y Lee; M S Kim; S H Choi; E C Chung; S H Kook; E Kim
Journal:  Br J Radiol       Date:  2014-12-23       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.