Literature DB >> 22251751

Natural history of stent edge dissection, tissue protrusion and incomplete stent apposition detectable only on optical coherence tomography after stent implantation – preliminary observation – .

Teruyoshi Kume1, Hiroyuki Okura, Yoshinori Miyamoto, Ryotaro Yamada, Ken Saito, Tomoko Tamada, Terumasa Koyama, Yoji Neishi, Akihiro Hayashida, Takahiro Kawamoto, Kiyoshi Yoshida.   

Abstract

BACKGROUND: The clinical impact of stent edge dissection, tissue protrusion, and incomplete stent apposition (ISA) after stent implantation, detectable only on optical coherence tomography (OCT), is still unknown because the natural course has not been investigated. METHODS AND
RESULTS: All consecutive patients with angina pectoris in whom both intravascular ultrasound (IVUS) and OCT were performed immediately after stenting and at follow-up were included in the present study. The natural history of OCT-detected stent edge dissection, tissue protrusion, and ISA during follow-up was investigated. A total of 36 patients with 39 lesions was analyzed. At baseline, OCT showed 12 stent edge dissections, 25 tissue protrusions, and 8 ISAs, whereas IVUS demonstrated 6 stent edge dissections, 5 tissue protrusions, and 3 ISAs. All IVUS findings were clearly visualized on OCT. The maximum length of dissection flap and depth of ISA visualized on OCT were significantly shorter than those visualized on IVUS. Maximum length of tissue protrusion tended to be smaller on OCT than on IVUS. At follow-up (median 188 days), all findings noted on OCT were healed or resolved without any restenosis or thrombus formation.
CONCLUSIONS: Acute findings after stenting, such as edge dissection, tissue protrusion, and ISA, detectable only on OCT, tended to be smaller than those seen on both OCT and IVUS. The majority of OCT-detected acute findings resolved completely at follow-up.

Entities:  

Mesh:

Year:  2012        PMID: 22251751     DOI: 10.1253/circj.cj-11-0845

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  19 in total

1.  Frequency and prognostic impact of intravascular imaging-guided urgent percutaneous coronary intervention in patients with acute myocardial infarction: results from J-MINUET.

Authors:  Hiroyuki Okura; Yoshihiko Saito; Tsunenari Soeda; Koichi Nakao; Yukio Ozaki; Kazuo Kimura; Junya Ako; Teruo Noguchi; Satoshi Yasuda; Satoru Suwa; Kazuteru Fujimoto; Yasuharu Nakama; Takashi Morita; Wataru Shimizu; Atsushi Hirohata; Yasuhiro Morita; Teruo Inoue; Atsunori Okamura; Masaaki Uematsu; Kazuhito Hirata; Kengo Tanabe; Yoshisato Shibata; Mafumi Owa; Kenichi Tsujita; Kunihiro Nishimura; Yoshihiro Miyamoto; Masaharu Ishihara
Journal:  Heart Vessels       Date:  2018-11-02       Impact factor: 2.037

2.  Unusual peri-stent strut contrast staining 6 years after sirolimus-eluting stent implantation: an "ant colony-like" appearance.

Authors:  Yoji Neishi; Hiroyuki Okura; Kiyoshi Yoshida
Journal:  Heart Vessels       Date:  2013-11-07       Impact factor: 2.037

3.  New insight to estimate under-expansion after stent implantation on bifurcation lesions using optical coherence tomography.

Authors:  Daisuke Nakamura; Guilherme F Attizzani; Setsu Nishino; Kentaro Tanaka; Mohamad Soud; Gabriel T Pereira; Milana Leygerman; Anas Fares; Audrey Schnell; Marco A Costa; Andrejs Erglis; Hiram G Bezerra
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-08       Impact factor: 2.357

4.  Intra-coronary imaging modalities.

Authors:  Paul M Johnson; Jigar Patel; Michael Yeung; Prashant Kaul
Journal:  Curr Treat Options Cardiovasc Med       Date:  2014-05

5.  A comparison of tissue prolapse with optical coherence tomography and intravascular ultrasound after drug-eluting stent implantation.

Authors:  Jihyun Sohn; Seung-Ho Hur; In-Cheol Kim; Yun-Kyeong Cho; Hyung-Seob Park; Hyuck-Jun Yoon; Chang-Wook Nam; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  Int J Cardiovasc Imaging       Date:  2014-10-02       Impact factor: 2.357

6.  Intravascular Ultrasound Versus Optical Coherence Tomography for Coronary Artery Imaging - Apples and Oranges?

Authors:  Krishnaraj S Rathod; Stephen M Hamshere; Daniel A Jones; Anthony Mathur
Journal:  Interv Cardiol       Date:  2015-03

7.  Detection of myocardial bridge by optical coherence tomography.

Authors:  Akihiko Okamura; Hiroyuki Okura; Saki Iwai; Atsushi Kyodo; Daisuke Kamon; Yukihiro Hashimoto; Tomoya Ueda; Tsunenari Soeda; Makoto Watanabe; Yoshihiko Saito
Journal:  Int J Cardiovasc Imaging       Date:  2022-01-11       Impact factor: 2.357

8.  Impact of strut-vessel distance and underlying plaque type on the resolution of acute strut malapposition: serial optimal coherence tomography analysis after everolimus-eluting stent implantation.

Authors:  Takumi Inoue; Toshiro Shinke; Hiromasa Otake; Masayuki Nakagawa; Hirotoshi Hariki; Tsuyoshi Osue; Masamichi Iwasaki; Yu Taniguchi; Ryo Nishio; Noritoshi Hiranuma; Akihide Konishi; Hiroto Kinutani; Masaru Kuroda; Ken-ichi Hirata
Journal:  Int J Cardiovasc Imaging       Date:  2014-04-19       Impact factor: 2.357

9.  Predictors and incidence of stent edge dissections in patients with type 2 diabetes as determined by optical coherence tomography.

Authors:  Sebastian Reith; Simone Battermann; Agnes Jaskolka; Walter Lehmacher; Rainer Hoffmann; Nikolaus Marx; Mathias Burgmaier
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-05       Impact factor: 2.357

10.  Optical Coherence Tomography Imaging: Novel Insights into the Vascular Response After Coronary Stent Implantation.

Authors:  Milosz Jaguszewski; Ulf Landmesser
Journal:  Curr Cardiovasc Imaging Rep       Date:  2012-05-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.