Literature DB >> 22249971

Influence of flow rate and scaffold pore size on cell behavior during mechanical stimulation in a flow perfusion bioreactor.

R J McCoy1, C Jungreuthmayer, F J O'Brien.   

Abstract

Mechanically stimulating cell-seeded scaffolds by flow-perfusion is one approach utilized for developing clinically applicable bone graft substitutes. A key challenge is determining the magnitude of stimuli to apply that enhances cell differentiation but minimizes cell detachment from the scaffold. In this study, we employed a combined computational modeling and experimental approach to examine how the scaffold mean pore size influences cell attachment morphology and subsequently impacts upon cell deformation and detachment when subjected to fluid-flow. Cell detachment from osteoblast-seeded collagen-GAG scaffolds was evaluated experimentally across a range of scaffold pore sizes subjected to different flow rates and exposure times in a perfusion bioreactor. Cell detachment was found to be proportional to flow rate and inversely proportional to pore size. Using this data, a theoretical model was derived that accurately predicted cell detachment as a function of mean shear stress, mean pore size, and time. Computational modeling of cell deformation in response to fluid flow showed the percentage of cells exceeding a critical threshold of deformation correlated with cell detachment experimentally and the majority of these cells were of a bridging morphology (cells stretched across pores). These findings will help researchers optimize the mean pore size of scaffolds and perfusion bioreactor operating conditions to manage cell detachment when mechanically simulating cells via flow perfusion.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22249971     DOI: 10.1002/bit.24424

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  16 in total

1.  Positive impact of dynamic seeding of mesenchymal stem cells on bone-like biodegradable scaffolds with increased content of calcium phosphate nanoparticles.

Authors:  Pavla Sauerova; Tomas Suchy; Monika Supova; Martin Bartos; Jiri Klima; Jana Juhasova; Stefan Juhas; Tereza Kubikova; Zbynek Tonar; Radek Sedlacek; Marco Piola; Gianfranco Beniamino Fiore; Monica Soncini; Marie Hubalek Kalbacova
Journal:  Mol Biol Rep       Date:  2019-06-10       Impact factor: 2.316

2.  Tissue-engineered 3D cancer-in-bone modeling: silk and PUR protocols.

Authors:  Ushashi Dadwal; Carolyne Falank; Heather Fairfield; Sarah Linehan; Clifford J Rosen; David L Kaplan; Julie Sterling; Michaela R Reagan
Journal:  Bonekey Rep       Date:  2016-10-19

3.  Investigating the interplay between substrate stiffness and ligand chemistry in directing mesenchymal stem cell differentiation within 3D macro-porous substrates.

Authors:  Matthew G Haugh; Ted J Vaughan; Christopher M Madl; Rosanne M Raftery; Laoise M McNamara; Fergal J O'Brien; Sarah C Heilshorn
Journal:  Biomaterials       Date:  2018-04-16       Impact factor: 12.479

4.  Computational investigation of interface printing patterns within 3D printed multilayered scaffolds for osteochondral tissue engineering.

Authors:  Robert Choe; Eoin Devoy; Blake Kuzemchak; Mary Sherry; Erfan Jabari; Jonathan D Packer; John P Fisher
Journal:  Biofabrication       Date:  2022-02-23       Impact factor: 9.954

5.  4-D Flow Control in Porous Scaffolds: Toward a Next Generation of Bioreactors.

Authors:  Khalid Youssef; Nanette N Jarenwattananon; Brian J Archer; Julia Mack; M Luisa Iruela-Arispe; Louis-S Bouchard
Journal:  IEEE Trans Biomed Eng       Date:  2016-03-02       Impact factor: 4.538

Review 6.  Biomechanical forces in the skeleton and their relevance to bone metastasis: biology and engineering considerations.

Authors:  Maureen E Lynch; Claudia Fischbach
Journal:  Adv Drug Deliv Rev       Date:  2014-08-29       Impact factor: 15.470

7.  Macro and microfluidic flows for skeletal regenerative medicine.

Authors:  Brandon D Riehl; Jung Yul Lim
Journal:  Cells       Date:  2012-12-11       Impact factor: 6.600

8.  Influence of Different Three-Dimensional Open Porous Titanium Scaffold Designs on Human Osteoblasts Behavior in Static and Dynamic Cell Investigations.

Authors:  Jana Markhoff; Jan Wieding; Volker Weissmann; Juliane Pasold; Anika Jonitz-Heincke; Rainer Bader
Journal:  Materials (Basel)       Date:  2015-08-24       Impact factor: 3.623

Review 9.  Protein Hydrogels: The Swiss Army Knife for Enhanced Mechanical and Bioactive Properties of Biomaterials.

Authors:  Carla Huerta-López; Jorge Alegre-Cebollada
Journal:  Nanomaterials (Basel)       Date:  2021-06-24       Impact factor: 5.076

10.  Immersed Boundary Models for Quantifying Flow-Induced Mechanical Stimuli on Stem Cells Seeded on 3D Scaffolds in Perfusion Bioreactors.

Authors:  Yann Guyot; Bart Smeets; Tim Odenthal; Ramesh Subramani; Frank P Luyten; Herman Ramon; Ioannis Papantoniou; Liesbet Geris
Journal:  PLoS Comput Biol       Date:  2016-09-22       Impact factor: 4.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.