Literature DB >> 22222623

Tailored excitation using nonlinear B0-shims.

Qi Duan1, Peter van Gelderen, Jeff Duyn.   

Abstract

In high-field MRI, RF flip angle inhomogeneity due to wavelength effects can lead to spatial variations in contrast and sensitivity. Improved flip angle homogeneity can be achieved through multidimensional excitation, but long RF pulse durations limit practical application. A recent approach to reduce RF pulse duration is based on parallel excitation through multiple RF channels. Here, an alternative approach to shorten multidimensional excitation is proposed that makes use of nonlinear spatial variations in the stationary (B(0)) magnetic field during a B(0)-sensitive excitation pulse. As initial demonstration, the method was applied to 2D gradient echo (GE) MRI of human brain at 7 T. Using B(0) shims with up to second-order spatial dependence, it is demonstrated that root-mean-squared flip angle variation can be reduced from 20 to 11% with RF pulse lengths that are practical for general GE imaging applications without requiring parallel excitation. The method is expected to improve contrast and sensitivity in GE MRI of human brain at high field.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22222623      PMCID: PMC3288151          DOI: 10.1002/mrm.23278

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Authors:  William Grissom; Chun-yu Yip; Zhenghui Zhang; V Andrew Stenger; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

2.  Real-time shimming to compensate for respiration-induced B0 fluctuations.

Authors:  P van Gelderen; J A de Zwart; P Starewicz; R S Hinks; J H Duyn
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

3.  Parallel RF transmission with eight channels at 3 Tesla.

Authors:  Kawin Setsompop; Lawrence L Wald; Vijayanand Alagappan; Borjan Gagoski; Franz Hebrank; Ulrich Fontius; Franz Schmitt; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2006-11       Impact factor: 4.668

4.  Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

Authors:  Adam C Zelinski; Lawrence L Wald; Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Vivek K Goyal; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

5.  A radiofrequency coil to facilitate B₁⁺ shimming and parallel imaging acceleration in three dimensions at 7 T.

Authors:  Kyle M Gilbert; Andrew T Curtis; Joseph S Gati; L Martyn Klassen; Ravi S Menon
Journal:  NMR Biomed       Date:  2010-12-08       Impact factor: 4.044

6.  Multicoil shimming of the mouse brain.

Authors:  Christoph Juchem; Peter B Brown; Terence W Nixon; Scott McIntyre; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2011-03-25       Impact factor: 4.668

7.  Dynamic Shimming of the Human Brain at 7 Tesla.

Authors:  Christoph Juchem; Terence W Nixon; Piotr Diduch; Douglas L Rothman; Piotr Starewicz; Robin A de Graaf
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2010-07-06       Impact factor: 1.176

8.  Dynamic B0 shimming at 7 T.

Authors:  Saikat Sengupta; E Brian Welch; Yansong Zhao; David Foxall; Piotr Starewicz; Adam W Anderson; John C Gore; Malcolm J Avison
Journal:  Magn Reson Imaging       Date:  2011-03-12       Impact factor: 2.546

9.  Fast large-tip-angle multidimensional and parallel RF pulse design in MRI.

Authors:  William A Grissom; Dan Xu; Adam B Kerr; Jeffrey A Fessler; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048

10.  Slice-selective RF pulses for in vivo B1+ inhomogeneity mitigation at 7 tesla using parallel RF excitation with a 16-element coil.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Borjan Gagoski; Thomas Witzel; Jonathan Polimeni; Andreas Potthast; Franz Hebrank; Ulrich Fontius; Franz Schmitt; Lawrence L Wald; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more
  3 in total

1.  Mitigation of B1+ inhomogeneity using spatially selective excitation with jointly designed quadratic spatial encoding magnetic fields and RF shimming.

Authors:  Yi-Cheng Hsu; Riccardo Lattanzi; Ying-Hua Chu; Martijn A Cloos; Daniel K Sodickson; Fa-Hsuan Lin
Journal:  Magn Reson Med       Date:  2016-10-02       Impact factor: 4.668

2.  Improved Bloch-Siegert based B1 mapping by reducing off-resonance shift.

Authors:  Qi Duan; Peter van Gelderen; Jeff Duyn
Journal:  NMR Biomed       Date:  2013-01-28       Impact factor: 4.044

3.  Radiofrequency pulse design using nonlinear gradient magnetic fields.

Authors:  Emre Kopanoglu; R Todd Constable
Journal:  Magn Reson Med       Date:  2014-09-09       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.