Literature DB >> 22219244

Reliability and validity of measuring version of the acetabular component.

J-H Nho1, Y-K Lee, H J Kim, Y-C Ha, Y-S Suh, K-H Koo.   

Abstract

A variety of radiological methods of measuring version of the acetabular component after total hip replacement (THR) have been described. The aim of this study was to evaluate the reliability and validity of six methods (those of Lewinnek; Widmer; Hassan et al; Ackland, Bourne and Uhthoff; Liaw et al; and Woo and Morrey) that are currently in use. In 36 consecutive patients who underwent THR, version of the acetabular component was measured by three independent examiners on plain radiographs using these six methods and compared with measurements using CT scans. The intra- and interobserver reliabilities of each measurement were estimated. All measurements on both radiographs and CT scans had excellent intra- and interobserver reliability and the results from each of the six methods correlated well with the CT measurements. However, measurements made using the methods of Widmer and of Ackland, Bourne and Uhthoff were significantly different from the CT measurements (both p < 0.001), whereas measurements made using the remaining four methods were similar to the CT measurements. With regard to reliability and convergent validity, we recommend the use of the methods described by Lewinnek, Hassan et al, Liaw et al and Woo and Morrey for measurement of version of the acetabular component.

Entities:  

Mesh:

Year:  2012        PMID: 22219244     DOI: 10.1302/0301-620X.94B1.27621

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  34 in total

1.  Acetabular component positioning using anatomic landmarks of the acetabulum.

Authors:  Yong-Chan Ha; Jeong Joon Yoo; Young-Kyun Lee; Jin Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2012-07-10       Impact factor: 4.176

2.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

3.  Fluoroscopy assessment during anterior minimally invasive hip replacement is more accurate than with the posterior approach.

Authors:  Weifeng Ji; Nathaniel Stewart
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

4.  Central X-ray beam correction of radiographic acetabular cup measurement after THA: an experimental study.

Authors:  T Schwarz; M Weber; M Wörner; T Renkawitz; J Grifka; B Craiovan
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-10-06       Impact factor: 2.924

5.  Can the crossover sign be a reliable marker of global retroversion of the acetabulum?

Authors:  Seyed Ali Hashemi; Javad Dehghani; Amir Reza Vosoughi
Journal:  Skeletal Radiol       Date:  2016-10-18       Impact factor: 2.199

6.  Accuracy of plain antero-posterior radiographic-based methods for measurement of acetabular cup version.

Authors:  Mohammad Ali Alzohiry; Mohammad Kamal Abdelnasser; Mohamed Moustafa; Mohamed Mahran; Hatem Bakr; Yaser Khalifa; Ahmed Abelaal; Haisam Atta; Galal Zaki Said
Journal:  Int Orthop       Date:  2018-06-04       Impact factor: 3.075

7.  Reliability and validity of measuring acetabular component orientation by plain anteroposterior radiographs.

Authors:  Ming Lu; Yi-Xin Zhou; Hui Du; Ji Zhang; Jian Liu
Journal:  Clin Orthop Relat Res       Date:  2013-05-04       Impact factor: 4.176

8.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

9.  Cross table lateral radiography for measurement of acetabular cup version.

Authors:  Olav Reikeras; Ragnhild Beate Gunderson
Journal:  Ann Transl Med       Date:  2016-05

10.  Does fluoroscopy with anterior hip arthroplasty decrease acetabular cup variability compared with a nonguided posterior approach?

Authors:  Parthiv A Rathod; Sean Bhalla; Ajit J Deshmukh; Jose A Rodriguez
Journal:  Clin Orthop Relat Res       Date:  2014-02-19       Impact factor: 4.176

View more