Literature DB >> 22217587

Validation of QuickScan dicentric chromosome analysis for high throughput radiation biological dosimetry.

F N Flegal1, Y Devantier, L Marro, R C Wilkins.   

Abstract

Currently, the dicentric chromosome assay (DCA) is used to estimate radiation doses to individuals following accidental radiological and nuclear overexposures when traditional dosimetry methods are not available. While being an exceptionally sensitive method for estimating doses by radiation, conventional DCA is time-intensive and requires highly trained expertise for analysis. For this reason, in a mass casualty situation, triage-quality conventional DCA struggles to provide dose estimations in a timely manner for triage purposes. In Canada, a new scoring technique, termed DCA QuickScan, has been devised to increase the throughput of this assay. DCA QuickScan uses traditional DCA sample preparation methods while adapting a rapid scoring approach. In this study, both conventional and QuickScan methods of scoring the DCA assay were compared for accuracy and sensitivity. Dose response curves were completed on four different donors based on the analysis of 1,000 metaphases or 200 events at eight to nine dose points by eight different scorers across two laboratories. Statistical analysis was performed on the data to compare the two methods within and across the laboratories and to test their respective sensitivities for dose estimation. This study demonstrated that QuickScan is statistically similar to conventional DCA analysis and is capable of producing dose estimates as low as 0.1 Gy but up to six times faster. Therefore, DCA QuickScan analysis can be used as a sensitive and accurate method for scoring samples for radiological biodosimetry in mass casualty situations or where faster dose assessment is required.

Entities:  

Mesh:

Year:  2012        PMID: 22217587     DOI: 10.1097/HP.0b013e3182307758

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  10 in total

1.  Web-based scoring of the dicentric assay, a collaborative biodosimetric scoring strategy for population triage in large scale radiation accidents.

Authors:  H Romm; E Ainsbury; A Bajinskis; S Barnard; J F Barquinero; L Barrios; C Beinke; R Puig-Casanovas; M Deperas-Kaminska; E Gregoire; U Oestreicher; C Lindholm; J Moquet; K Rothkamm; S Sommer; H Thierens; A Vral; V Vandersickel; A Wojcik
Journal:  Radiat Environ Biophys       Date:  2014-02-21       Impact factor: 1.925

2.  Evaluation of the annual Canadian biodosimetry network intercomparisons.

Authors:  Ruth C Wilkins; Lindsay A Beaton-Green; Sylvie Lachapelle; Barbara C Kutzner; Catherine Ferrarotto; Vinita Chauhan; Leonora Marro; Gordon K Livingston; Hillary Boulay Greene; Farrah N Flegal
Journal:  Int J Radiat Biol       Date:  2015-02-27       Impact factor: 2.694

Review 3.  Nuclear and Radiological Emergencies: Biological Effects, Countermeasures and Biodosimetry.

Authors:  Elena Obrador; Rosario Salvador-Palmer; Juan I Villaescusa; Eduardo Gallego; Blanca Pellicer; José M Estrela; Alegría Montoro
Journal:  Antioxidants (Basel)       Date:  2022-05-31

4.  Assessment of biodosimetry methods for a mass-casualty radiological incident: medical response and management considerations.

Authors:  Julie M Sullivan; Pataje G S Prasanna; Marcy B Grace; Lynne K Wathen; Rodney L Wallace; John F Koerner; C Norman Coleman
Journal:  Health Phys       Date:  2013-12       Impact factor: 1.316

5.  Optimizing the Microscopy Time Schedule for Chromosomal Dosimetry of High-dose and Partial-body Irradiations.

Authors:  Volodymyr A Vinnikov
Journal:  Genome Integr       Date:  2017-01-23

Review 6.  The Application of Imaging Flow Cytometry to High-Throughput Biodosimetry.

Authors:  Ruth C Wilkins; Matthew A Rodrigues; Lindsay A Beaton-Green
Journal:  Genome Integr       Date:  2017-01-23

7.  Validation of the dicentric chromosome assay for radiation biological dosimetry in South Korea.

Authors:  Younghyun Lee; Young Woo Jin; Ruth C Wilkins; Seongjae Jang
Journal:  J Radiat Res       Date:  2019-10-23       Impact factor: 2.724

8.  Medical management of acute responses to radiation.

Authors:  Nelson J Chao; Cullen Case; Dennis Confer
Journal:  Hemasphere       Date:  2019-06-30

9.  Complete Technical Scheme for Automatic Biological Dose Estimation Platform.

Authors:  Hong Dai; Junchao Feng; Huahui Bian; Weibo Chen; Youyou Wang; Yulong Liu; Wentao Hu
Journal:  Dose Response       Date:  2018-10-03       Impact factor: 2.658

10.  High-Accuracy Relative Biological Effectiveness Values Following Low-Dose Thermal Neutron Exposures Support Bimodal Quality Factor Response with Neutron Energy.

Authors:  Laura C Paterson; Amy Festarini; Marilyne Stuart; Fawaz Ali; Christie Costello; Chad Boyer; Ronald Rogge; Norma Ybarra; John Kildea; Richard B Richardson
Journal:  Int J Mol Sci       Date:  2022-01-14       Impact factor: 5.923

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.