Literature DB >> 22215278

A numerical investigation of blood damage in the hinge area of aortic bileaflet mechanical heart valves during the leakage phase.

B Min Yun1, Jingshu Wu, Helene A Simon, Shiva Arjunon, Fotis Sotiropoulos, Cyrus K Aidun, Ajit P Yoganathan.   

Abstract

Previous experimental and numerical blood studies have shown that high shear stress levels, long exposure times to these shear stresses, and flow recirculation promote thromboembolism. Artificial heart valves, in particular bileaflet mechanical heart valves (BMHVs), are prone to developing thromboembolic complications. These complications often form at the hinge regions of BMHVs and the associated geometry has been shown to affect the local flow dynamics and the associated thrombus formation. However, to date no study has focused on simulating the motion of realistically modeled blood elements within the hinge region to numerically estimate the hinge-related blood damage. Consequently, this study aims at (a) simulating the motion of realistically modeled platelets during the leakage (mid-diastole) phase in different BMHV hinge designs placed in the aortic position and (b) quantitatively comparing the blood damage associated with different designs. Three designs are investigated to assess the effects of hinge geometry and dimensions: a 23 mm St. Jude Medical Regent™ valve hinge with two different gap distances between the leaflet ear and hinge recess; and a 23 mm CarboMedics (CM) aortic valve hinge. The recently developed lattice-Boltzmann method with external boundary force method is used to simulate the hinge flow and capture the dynamics and surface shear stresses of individual platelets. A blood damage index (BDI) value is then estimated based on a linear shear stress-exposure time BDI model. The velocity boundary conditions are obtained from previous 3D large-scale simulations of the hinge flow fields. The trajectories of the blood elements in the hinge region are found to be qualitatively similar for all three hinges, but the shear stresses experienced by individual platelets are higher for the CM hinge design, leading to a higher BDI. The results of this study are also shown to be in good agreement with previous studies, thus validating the numerical method for future research in BMHV flows. This study provides a general numerical tool to optimize the hinge design based on both hemodynamic and thromboembolic performance.

Entities:  

Mesh:

Year:  2012        PMID: 22215278     DOI: 10.1007/s10439-011-0502-3

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  16 in total

1.  Mechanical platelet activation potential in abdominal aortic aneurysms.

Authors:  Kirk B Hansen; Amirhossein Arzani; Shawn C Shadden
Journal:  J Biomech Eng       Date:  2015-02-05       Impact factor: 2.097

2.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

Review 3.  Review of numerical methods for simulation of mechanical heart valves and the potential for blood clotting.

Authors:  Mohamad Shukri Zakaria; Farzad Ismail; Masaaki Tamagawa; Ahmad Fazli Abdul Aziz; Surjatin Wiriadidjaja; Adi Azrif Basri; Kamarul Arifin Ahmad
Journal:  Med Biol Eng Comput       Date:  2017-07-26       Impact factor: 2.602

4.  Blood damage through a bileaflet mechanical heart valve: a quantitative computational study using a multiscale suspension flow solver.

Authors:  B Min Yun; Cyrus K Aidun; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2014-10       Impact factor: 2.097

5.  Effect of hinge gap width of a St. Jude medical bileaflet mechanical heart valve on blood damage potential--an in vitro micro particle image velocimetry study.

Authors:  Brian H Jun; Neelakantan Saikrishnan; Sivakkumar Arjunon; B Min Yun; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2014-09       Impact factor: 2.097

Review 6.  Recent advances in computational methodology for simulation of mechanical circulatory assist devices.

Authors:  Alison L Marsden; Yuri Bazilevs; Christopher C Long; Marek Behr
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2014-01-21

7.  Dynamic and fluid-structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models.

Authors:  Ming-Chen Hsu; David Kamensky; Fei Xu; Josef Kiendl; Chenglong Wang; Michael C H Wu; Joshua Mineroff; Alessandro Reali; Yuri Bazilevs; Michael S Sacks
Journal:  Comput Mech       Date:  2015-06       Impact factor: 4.014

8.  Scalability Test of Multiscale Fluid-Platelet Model for Three Top Supercomputers.

Authors:  Peng Zhang; Na Zhang; Chao Gao; Li Zhang; Yuxiang Gao; Yuefan Deng; Danny Bluestein
Journal:  Comput Phys Commun       Date:  2016-04-08       Impact factor: 4.390

9.  A novel mathematical model of activation and sensitization of platelets subjected to dynamic stress histories.

Authors:  João S Soares; Jawaad Sheriff; Danny Bluestein
Journal:  Biomech Model Mechanobiol       Date:  2013-01-29

Review 10.  Lagrangian postprocessing of computational hemodynamics.

Authors:  Shawn C Shadden; Amirhossein Arzani
Journal:  Ann Biomed Eng       Date:  2014-07-25       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.