Literature DB >> 22203707

Interventional 4-D C-arm CT perfusion imaging using interleaved scanning and partial reconstruction interpolation.

Andreas Fieselmann1, Arundhuti Ganguly, Yu Deuerling-Zheng, Michael Zellerhoff, Christopher Rohkohl, Jan Boese, Joachim Hornegger, Rebecca Fahrig.   

Abstract

Tissue perfusion measurement during catheter-guided stroke treatment in the interventional suite is currently not possible. In this work, we present a novel approach that uses a C-arm angiography system capable of computed tomography (CT)-like imaging (C-arm CT) for this purpose. With C-arm CT one reconstructed volume can be obtained every 4-6 s which makes it challenging to measure the flow of an injected contrast bolus. We have developed an interleaved scanning (IS) protocol that uses several scan sequences to increase temporal sampling. Using a dedicated 4-D reconstruction approach based on partial reconstruction interpolation (PRI) we can optimally process our data. We evaluated our combined approach (IS-PRI) with simulations and a study in five healthy pigs. In our simulations, the cerebral blood flow values (unit: ml/100 g/min) were 60 (healthy tissue) and 20 (pathological tissue). For one scan sequence the values were estimated with standard deviations of 14.3 and 2.9, respectively. For two interleaved sequences the standard deviations decreased to 3.6 and 1.5, respectively. We used perfusion CT to validate the in vivo results. With two interleaved sequences we achieved promising correlations ranging from r=0.63 to r=0.94. The results suggest that C-arm CT tissue perfusion imaging is feasible with two interleaved scan sequences.

Entities:  

Mesh:

Year:  2011        PMID: 22203707     DOI: 10.1109/TMI.2011.2181531

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  10 in total

1.  An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.

Authors:  Yinsheng Li; John W Garrett; Ke Li; Charles Strother; Guang-Hong Chen
Journal:  IEEE Trans Med Imaging       Date:  2019-12-20       Impact factor: 10.048

2.  Dynamic Angiography and Perfusion Imaging Using Flat Detector CT in the Angiography Suite: A Pilot Study in Patients with Acute Middle Cerebral Artery Occlusions.

Authors:  T Struffert; Y Deuerling-Zheng; S Kloska; T Engelhorn; S Lang; A Mennecke; M Manhart; C M Strother; S Schwab; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2015-06-11       Impact factor: 3.825

3.  In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging.

Authors:  A Ganguly; A Fieselmann; J Boese; C Rohkohl; J Hornegger; R Fahrig
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

4.  C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients.

Authors:  Mudassar Kamran; James V Byrne
Journal:  Neuroradiology       Date:  2015-05-29       Impact factor: 2.804

5.  Inferring CT perfusion parameters and uncertainties using a Bayesian approach.

Authors:  Tao Sun; Roger Fulton; Zhanli Hu; Christina Sutiono; Dong Liang; Hairong Zheng
Journal:  Quant Imaging Med Surg       Date:  2022-01

6.  C-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection.

Authors:  K Royalty; M Manhart; K Pulfer; Y Deuerling-Zheng; C Strother; A Fieselmann; D Consigny
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-23       Impact factor: 3.825

7.  Three-dimensional regions-of-interest-based intra-operative four-dimensional soft tissue perfusion imaging using a standard x-ray system with no gantry rotation: A simulation study for a proof of concept.

Authors:  Katsuyuki Taguchi; Thomas J Sauer; W Paul Segars; Eric C Frey; Jingyan Xu; Eleni Liapi; J Webster Stayman; Kelvin Hong; Ferdinand K Hui; Mathias Unberath; Yong Du
Journal:  Med Phys       Date:  2020-10-22       Impact factor: 4.071

8.  Time density curve analysis for C-arm FDCT PBV imaging.

Authors:  Mudassar Kamran; James V Byrne
Journal:  Interv Neuroradiol       Date:  2016-01-14       Impact factor: 1.610

9.  Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review.

Authors:  Ernst L Stille; Ilaria Viozzi; Mark Ter Laan; Frederick J A Meijer; Jurgen J Futterer; Maroeska M Rovers
Journal:  Neuroradiology       Date:  2019-09-16       Impact factor: 2.804

10.  Using Flat-Panel Perfusion Imaging to Measure Cerebral Hemodynamics: A Pilot Feasibility Study in Patients With Carotid Stenosis.

Authors:  Chung-Jung Lin; Wan-Yuo Guo; Feng-Chi Chang; Sheng-Che Hung; Ko-Kung Chen; Deuerling-Zheng Yu; Chun-Hsien Frank Wu; Jy-Kang Adrian Liou
Journal:  Medicine (Baltimore)       Date:  2016-05       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.