Literature DB >> 22200308

Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry.

Paula Berton1, Estefanía M Martinis, Luis D Martinez, Rodolfo G Wuilloud.   

Abstract

In the present work, a simple and rapid analytical method based on application of ionic liquids (ILs) for inorganic Co(II) species (iCo) microextraction in a variety of nutrient supplements was developed. Inorganic Co was initially chelated with 1-nitroso-2-naphtol (1N2N) reagent followed by a modern technique named ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction (USA-TILDLME). The extraction was performed with 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)mim][PF(6)] with the aid of ultrasound to improve iCo recovery. Finally, the iCo-enriched IL phase was solubilized in methanol and directly injected into an electrothermal atomic absorption spectrometer (ETAAS). Several parameters that could influence iCo microextraction and detection were carefully studied. Since the main difficulty in these samples is caused by high concentrations of potential interfering ions, different approaches were evaluated to eliminate interferences. The limit of detection (LOD) was 5.4 ng L(-1), while the relative standard deviation (RSD) was 4.7% (at 0.5 μg L(-1) Co level and n=10), calculated from the peak height of absorbance signals. Selective microextraction of iCo species was achieved only by controlling the pH value during the procedure. The method was thus successfully applied for determination of iCo species in nutritional supplements.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22200308     DOI: 10.1016/j.aca.2011.11.024

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Sensitive spectrophotometric determination of Co(II) using dispersive liquid-liquid micro-extraction method in soil samples.

Authors:  Foroozan Hasanpour; Hassan Hadadzadeh; Masoumeh Taei; Mohsen Nekouei; Elmira Mozafari
Journal:  Environ Monit Assess       Date:  2016-04-04       Impact factor: 2.513

2.  Simultaneous determination of brazilin and protosappanin B in Caesalpinia sappan by ionic-liquid dispersive liquid-phase microextraction method combined with HPLC.

Authors:  Zhaoyang Xia; Dongdong Li; Qing Li; Yan Zhang; Wenyi Kang
Journal:  Chem Cent J       Date:  2017-11-13       Impact factor: 4.215

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.