Literature DB >> 22198797

Assessing corneal hysteresis using the Ocular Response Analyzer.

Charles W McMonnies1.   

Abstract

PURPOSE: An examination of studies that have assessed corneal biomechanical performance using the Ocular Response Analyzer (ORA: Reichert Ophthalmic Instruments, Depew, NY) raises some questions regarding the influence of measurement variables and the interpretation of the findings obtained with this instrument. This analysis of those questions describes additional factors which do or may contribute to the assessment of corneal hysteresis (CH).
METHODS: Using key words CH and ORA, English language articles relevant to this analysis were selected after a PubMed search with the addition of some articles referenced in the selected publications.
RESULTS: Corneal thickness, the level of edema, intraocular pressure, and corneal temperature as well as the area, location, rate, duration, and sequence of corneal unloading and loading may need to be considered as significant variables when assessing CH.
CONCLUSIONS: CH values may be specific to measurement method and conditions rather than representing an unequivocal corneal property. Consideration of the uncontrolled variables involved may help explain some of the findings obtained with the ORA. That a CH measurement might vary with the sequence of unloading and loading suggests that the ORA CH finding may not represent the CH, but instead represents a hysteresis value better described as central, applanation-derived hysteresis, which is based on a very short unloading/loading sequence. The potential for the ORA to contribute to improved clinical management appears to be considerable but so does the need for better understanding and further development of its functions and applications.

Entities:  

Mesh:

Year:  2012        PMID: 22198797     DOI: 10.1097/OPX.0b013e3182417223

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  13 in total

1.  Dynamic contour tonometry over silicone hydrogel contact lens.

Authors:  Andrew K C Lam; Jimmy S H Tse
Journal:  J Optom       Date:  2013-08-28

2.  Anterior pituitary, sex hormones, and keratoconus: Beyond traditional targets.

Authors:  Dimitrios Karamichos; Paulina Escandon; Brenda Vasini; Sarah E Nicholas; Lyly Van; Deanna H Dang; Rebecca L Cunningham; Kamran M Riaz
Journal:  Prog Retin Eye Res       Date:  2021-11-02       Impact factor: 19.704

3.  In Vivo Corneal Biomechanical Properties with Corneal Visualization Scheimpflug Technology in Chinese Population.

Authors:  Ying Wu; Lei Tian; Yi-Fei Huang
Journal:  Biomed Res Int       Date:  2016-07-14       Impact factor: 3.411

4.  Application of Corvis ST to evaluate the effect of femtosecond laser-assisted cataract surgery on corneal biomechanics.

Authors:  Yinjuan Wei; Lingxiao Xu; Hui Song
Journal:  Exp Ther Med       Date:  2017-06-26       Impact factor: 2.447

Review 5.  Advances in Biomechanical Parameters for Screening of Refractive Surgery Candidates: A Review of the Literature, Part III.

Authors:  Majid Moshirfar; Mahsaw N Motlagh; Michael S Murri; Hamed Momeni-Moghaddam; Yasmyne C Ronquillo; Phillip C Hoopes
Journal:  Med Hypothesis Discov Innov Ophthalmol       Date:  2019

6.  Correlation between corneal thickness, keratometry, age, and differential pressure difference in healthy eyes.

Authors:  Ahmet Colakoglu; Iffet Emel Colakoglu; Cemile Banu Cosar
Journal:  Sci Rep       Date:  2021-02-18       Impact factor: 4.379

7.  Corneal Biomechanical Properties in Varying Severities of Myopia.

Authors:  Mohammad-Reza Sedaghat; Hamed Momeni-Moghaddam; Abbas Azimi; Zohreh Fakhimi; Mohammed Ziaei; Zeynad Danesh; Cynthia J Roberts; Naeemeh Monfared; Alireza Jamali
Journal:  Front Bioeng Biotechnol       Date:  2021-01-21

8.  Evaluation of corneal deformation analyzed with Scheimpflug based device in healthy eyes and diseased ones.

Authors:  Michele Lanza; Michela Cennamo; Stefania Iaccarino; Carlo Irregolare; Miguel Rechichi; Mario Bifani; Ugo Antonello Gironi Carnevale
Journal:  Biomed Res Int       Date:  2014-06-23       Impact factor: 3.411

Review 9.  Theoretical basis, laboratory evidence, and clinical research of chemical surgery of the cornea: cross-linking.

Authors:  Amanda C da Paz; Patrícia A Bersanetti; Marcella Q Salomão; Renato Ambrósio; Paulo Schor
Journal:  J Ophthalmol       Date:  2014-08-18       Impact factor: 1.909

10.  Relationship between the biomechanical properties of the cornea and anterior segment measurements.

Authors:  Murilo Barreto Souza; Fabricio Witzel de Medeiros; Flavio Fernandes Villela; Milton Ruiz Alves
Journal:  Clinics (Sao Paulo)       Date:  2018-09-21       Impact factor: 2.365

View more