Literature DB >> 22188976

Reporting of quantitative oxygen mapping in EPR imaging.

Sankaran Subramanian1, Nallathamby Devasahayam, Alan McMillan, Shingo Matsumoto, Jeeva P Munasinghe, Keita Saito, James B Mitchell, Gadisetti V R Chandramouli, Murali C Krishna.   

Abstract

Oxygen maps derived from electron paramagnetic resonance spectral-spatial imaging (EPRI) are based upon the relaxivity of molecular oxygen with paramagnetic spin probes. This technique can be combined with MRI to facilitate mapping of pO(2) values in specific anatomic locations with high precision. The co-registration procedure, which matches the physical and digital dimensions of EPR and MR images, may present the pO(2) map at the higher MRI resolution, exaggerating the spatial resolution of oxygen, making it difficult to precisely distinguish hypoxic regions from normoxic regions. The latter distinction is critical in monitoring the treatment of cancer by radiation and chemotherapy, since it is well-established that hypoxic regions are three or four times more resistant to treatment compared to normoxic regions. The aim of this article is to describe pO(2) maps based on the intrinsic resolution of EPRI. A spectral parameter that affects the intrinsic spatial resolution of EPRI is the full width at half maximum (FWHM) height of the gradient-free EPR absorption line in frequency-encoded imaging. In single point imaging too, the transverse relaxation times (T(2)(∗)) limit the resolution since the signal decays by exp(-t(p)/T(2)(∗)) where the delay time after excitation pulse, t(p), is related to the resolution. Although the spin densities of two point objects may be resolved at this separation, it is inadequate to evaluate quantitative changes of pO(2) levels since the linewidths are proportionately affected by pO(2). A spatial separation of at least twice this resolution is necessary to correctly identify a change in pO(2) level. In addition, the pO(2) values are blurred by uncertainties arising from spectral dimensions. Blurring due to noise and low resolution modulates the pO(2) levels at the boundaries of hypoxic and normoxic regions resulting in higher apparent pO(2) levels in hypoxic regions. Therefore, specification of intrinsic resolution and pO(2) uncertainties are necessary to interpret digitally processed pO(2) illustrations. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22188976      PMCID: PMC3278905          DOI: 10.1016/j.jmr.2011.11.013

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  10 in total

1.  Quantitative tumor oxymetric images from 4D electron paramagnetic resonance imaging (EPRI): methodology and comparison with blood oxygen level-dependent (BOLD) MRI.

Authors:  Martyna Elas; Benjamin B Williams; Adrian Parasca; Colin Mailer; Charles A Pelizzari; Marta A Lewis; Jonathan N River; Gregory S Karczmar; Eugene D Barth; Howard J Halpern
Journal:  Magn Reson Med       Date:  2003-04       Impact factor: 4.668

2.  Pharmacokinetics of a triarylmethyl-type paramagnetic spin probe used in EPR oximetry.

Authors:  Ken-Ichiro Matsumoto; Sean English; John Yoo; Ken-Ichi Yamada; Nallathamby Devasahayam; John A Cook; James B Mitchell; Sankaran Subramanian; Murali C Krishna
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

Review 3.  Spatially resolved biologic information from in vivo EPRI, OMRI, and MRI.

Authors:  Ken-ichiro Matsumoto; Sankaran Subramanian; Ramachandran Murugesan; James B Mitchell; Murali C Krishna
Journal:  Antioxid Redox Signal       Date:  2007-08       Impact factor: 8.401

4.  Strategies for improved temporal and spectral resolution in in vivo oximetric imaging using time-domain EPR.

Authors:  Nallathamby Devasahayam; Sankaran Subramanian; Ramachandran Murugesan; Fuminori Hyodo; Ken-Ichiro Matsumoto; James B Mitchell; Murali C Krishna
Journal:  Magn Reson Med       Date:  2007-04       Impact factor: 4.668

Review 5.  Tumor hypoxia, drug resistance, and metastases.

Authors:  J M Brown
Journal:  J Natl Cancer Inst       Date:  1990-03-07       Impact factor: 13.506

Review 6.  Principles of computer assisted tomography (CAT) in radiographic and radioisotopic imaging.

Authors:  R A Brooks; G Di Chiro
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

Review 7.  Tumor hypoxia: definitions and current clinical, biologic, and molecular aspects.

Authors:  M Höckel; P Vaupel
Journal:  J Natl Cancer Inst       Date:  2001-02-21       Impact factor: 13.506

8.  Noninvasive in vivo oximetric imaging by radiofrequency FT EPR.

Authors:  Sankaran Subramanian; Ken-Ichi Yamada; Akira Irie; Ramachandran Murugesan; John A Cook; Nallathamby Devasahayam; Gootzian M Van Dam; James B Mitchell; Murali C Krishna
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

9.  Association between tumor hypoxia and malignant progression in advanced cancer of the uterine cervix.

Authors:  M Hockel; K Schlenger; B Aral; M Mitze; U Schaffer; P Vaupel
Journal:  Cancer Res       Date:  1996-10-01       Impact factor: 12.701

10.  Biodistribution, pharmacokinetics and PET imaging of [(18)F]FMISO, [(18)F]FDG and [(18)F]FAc in a sarcoma- and inflammation-bearing mouse model.

Authors:  Ren-Shyan Liu; Ta-Kai Chou; Chih-Hsien Chang; Chun-Yi Wu; Chi-Wei Chang; Tsui-Jung Chang; Shih-Jen Wang; Wuu-Jyh Lin; Hsin-Ell Wang
Journal:  Nucl Med Biol       Date:  2009-04       Impact factor: 2.408

  10 in total
  9 in total

1.  Accelerated 4D quantitative single point EPR imaging using model-based reconstruction.

Authors:  Hyungseok Jang; Shingo Matsumoto; Nallathamby Devasahayam; Sankaran Subramanian; Jiachen Zhuo; Murali C Krishna; Alan B McMillan
Journal:  Magn Reson Med       Date:  2014-05-06       Impact factor: 4.668

2.  Functional electron paramagnetic resonance imaging of ischemic rat heart: Monitoring of tissue oxygenation and pH.

Authors:  Artem A Gorodetsky; Igor A Kirilyuk; Valery V Khramtsov; Denis A Komarov
Journal:  Magn Reson Med       Date:  2015-08-24       Impact factor: 4.668

3.  Single acquisition quantitative single-point electron paramagnetic resonance imaging.

Authors:  Hyungseok Jang; Sankaran Subramanian; Nallathamby Devasahayam; Keita Saito; Shingo Matsumoto; Murali C Krishna; Alan B McMillan
Journal:  Magn Reson Med       Date:  2013-08-01       Impact factor: 4.668

4.  Dynamic Quantum Sensing of Paramagnetic Species Using Nitrogen-Vacancy Centers in Diamond.

Authors:  Valentin Radu; Joshua Colm Price; Simon James Levett; Kaarjel Kauslya Narayanasamy; Thomas David Bateman-Price; Philippe Barrie Wilson; Melissa Louise Mather
Journal:  ACS Sens       Date:  2020-01-08       Impact factor: 7.711

5.  High fidelity triangular sweep of the magnetic field for millisecond scan EPR imaging.

Authors:  Denis A Komarov; Alexandre Samouilov; Hiroshi Hirata; Jay L Zweier
Journal:  J Magn Reson       Date:  2021-06-09       Impact factor: 2.734

Review 6.  In vivo electron paramagnetic resonance oximetry and applications in the brain.

Authors:  John M Weaver; Ke Jian Liu
Journal:  Med Gas Res       Date:  2017-03-30

Review 7.  EPR Everywhere.

Authors:  Joshua R Biller; Joseph E McPeak
Journal:  Appl Magn Reson       Date:  2021-01-24       Impact factor: 0.831

Review 8.  The Role of Imaging Biomarkers to Guide Pharmacological Interventions Targeting Tumor Hypoxia.

Authors:  Bernard Gallez
Journal:  Front Pharmacol       Date:  2022-07-15       Impact factor: 5.988

Review 9.  In vivo evaluation of different alterations of redox status by studying pharmacokinetics of nitroxides using magnetic resonance techniques.

Authors:  Goran Bačić; Aleksandra Pavićević; Fabienne Peyrot
Journal:  Redox Biol       Date:  2015-11-14       Impact factor: 11.799

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.