Literature DB >> 12652539

Quantitative tumor oxymetric images from 4D electron paramagnetic resonance imaging (EPRI): methodology and comparison with blood oxygen level-dependent (BOLD) MRI.

Martyna Elas1, Benjamin B Williams, Adrian Parasca, Colin Mailer, Charles A Pelizzari, Marta A Lewis, Jonathan N River, Gregory S Karczmar, Eugene D Barth, Howard J Halpern.   

Abstract

This work presents a methodology for obtaining quantitative oxygen concentration images in the tumor-bearing legs of living C3H mice. The method uses high-resolution electron paramagnetic resonance imaging (EPRI). Enabling aspects of the methodology include the use of injectable, narrow, single-line triaryl methyl spin probes and an accurate model of overmodulated spectra. Both of these increase the signal-to-noise ratio (SNR), resulting in high resolution in space (1 mm)(3) and oxygen concentrations (approximately 3 torr). Thresholding at 15% the maximum spectral amplitude gives leg/tumor shapes that reproduce those in photographs. The EPRI appears to give reasonable oxygen partial pressures, showing hypoxia (approximately 0-6 torr, 0-10(3) Pa) in many of the tumor voxels. EPRI was able to detect statistically significant changes in oxygen concentrations in the tumor with administration of carbogen, although the changes were not increased uniformly. As a demonstration of the method, EPRI was compared with nearly concurrent (same anesthesia) T(2)*/blood oxygen level-dependent (BOLD) MRI. There was a good spatial correlation between EPRI and MRI. Homogeneous and heterogeneous T(2)*/BOLD MRI correlated well with the quantitative EPRI. This work demonstrates the potential for EPRI to display, at high spatial resolution, quantitative oxygen tension changes in the physiologic response to environmental changes. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12652539     DOI: 10.1002/mrm.10408

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  79 in total

1.  Electron paramagnetic resonance monitoring of ischemia-induced myocardial oxygen depletion and acidosis in isolated rat hearts using soluble paramagnetic probes.

Authors:  Denis A Komarov; Ilirian Dhimitruka; Igor A Kirilyuk; Dmitrii G Trofimiov; Igor A Grigor'ev; Jay L Zweier; Valery V Khramtsov
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  Multiple-stepped Zeeman field offset method applied in acquiring enhanced resolution spin-echo electron paramagnetic resonance images.

Authors:  Payam Seifi; Boris Epel; Colin Mailer; Howard J Halpern
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Low-field magnetic resonance imaging to visualize chronic and cycling hypoxia in tumor-bearing mice.

Authors:  Hironobu Yasui; Shingo Matsumoto; Nallathamby Devasahayam; Jeeva P Munasinghe; Rajani Choudhuri; Keita Saito; Sankaran Subramanian; James B Mitchell; Murali C Krishna
Journal:  Cancer Res       Date:  2010-07-20       Impact factor: 12.701

4.  Spatially uniform sampling in 4-D EPR spectral-spatial imaging.

Authors:  Kang-Hyun Ahn; Howard J Halpern
Journal:  J Magn Reson       Date:  2006-12-15       Impact factor: 2.229

5.  Simulation of 4D spectral-spatial EPR images.

Authors:  Kang-Hyun Ahn; Howard J Halpern
Journal:  J Magn Reson       Date:  2007-03-01       Impact factor: 2.229

Review 6.  Imaging tumor hypoxia to advance radiation oncology.

Authors:  Chen-Ting Lee; Mary-Keara Boss; Mark W Dewhirst
Journal:  Antioxid Redox Signal       Date:  2014-03-24       Impact factor: 8.401

7.  Generation of Trityl Radicals by Nucleophilic Quenching of Tris(2,3,5,6-tetrathiaaryl)methyl Cations and Practical and Convenient Large-Scale Synthesis of Persistent Tris(4-carboxy-2,3,5,6-tetrathiaaryl)methyl Radical.

Authors:  Olga Yu Rogozhnikova; Vladimir G Vasiliev; Tatiana I Troitskaya; Dmitry V Trukhin; Tatiana V Mikhalina; Howard J Halpern; Victor M Tormyshev
Journal:  European J Org Chem       Date:  2013-06-01

8.  In vivo EPR oximetry using an isotopically-substituted nitroxide: Potential for quantitative measurement of tissue oxygen.

Authors:  John Weaver; Scott R Burks; Ke Jian Liu; Joseph P Y Kao; Gerald M Rosen
Journal:  J Magn Reson       Date:  2016-08-16       Impact factor: 2.229

9.  Four-channel surface coil array for 300-MHz pulsed EPR imaging: proof-of-concept experiments.

Authors:  Ayano Enomoto; Hiroshi Hirata; Shingo Matsumoto; Keita Saito; Sankaran Subramanian; Murali C Krishna; Nallathamby Devasahayam
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  Characterization of response to radiation mediated gene therapy by means of multimodality imaging.

Authors:  Chad R Haney; Adrian D Parasca; Xiaobing Fan; Rebecca M Bell; Marta A Zamora; Gregory S Karczmar; Helena J Mauceri; Howard J Halpern; Ralph R Weichselbaum; Charles A Pelizzari
Journal:  Magn Reson Med       Date:  2009-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.