Evaluation of non-selective refocusing pulses for 7 T MRI.

Jay Moore1, Marcin Jankiewicz, Adam W Anderson, John C Gore.   

Abstract

There is a continuing need for improved RF pulses that achieve proper refocusing in the context of ultra-high field (≥ 7 T) human MRI. Simple block or sinc pulses are highly susceptible to RF field inhomogeneities, and adiabatic pulses are generally considered too SAR intensive for practical use at 7 T. The performance of the array of pulses falling between these extremes, however, has not been systematically evaluated. The aim of this work was to compare the performances of 21 non-selective refocusing pulses spanning a range of durations and SAR levels. The evaluation was based upon simulations and both phantom and in vivo human brain experiments conducted at 7 T. Tested refocusing designs included block, composite block, BIR-4, hyperbolic secant, and numerically optimized composite waveforms. These pulses were divided into three SAR classes and two duration categories, and, based on signal gain in a 3-D spin echo sequence, practical recommendations on usage are made within each category. All evaluated pulses were found to produce greater volume-averaged signals relative to a 180° block pulse. Although signal gains often come with the price of increased SAR or duration, some pulses were found to result in significant signal enhancement while also adhering to practical constraints. This work demonstrates the signal gains and losses realizable with single-channel refocusing pulse designs and should assist in the selection of suitable refocusing pulses for practical 3-D spin-echo imaging at 7 T. It further establishes a reference against which future pulses and multi-channel designs can be compared.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22177384      PMCID: PMC3257423          DOI: 10.1016/j.jmr.2011.11.010

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  19 in total

1.  B1 and B0 inhomogeneity mitigation in the human brain at 7 T with selective pulses by using average Hamiltonian theory.

Authors:  N Boulant; M A Cloos; A Amadon
Journal:  Magn Reson Med       Date:  2010-10-14       Impact factor: 4.668

2.  Adiabatic refocusing pulses for volume selection in magnetic resonance spectroscopic imaging.

Authors:  Laura I Sacolick; Douglas L Rothman; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

3.  Design of phase-modulated broadband refocusing pulses.

Authors:  Rolf F Schulte; Patrick Le Roux; Mika W Vogel; Hartmut Koenig
Journal:  J Magn Reson       Date:  2008-02       Impact factor: 2.229

4.  Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.

Authors:  Adam C Zelinski; Lawrence L Wald; Kawin Setsompop; Vijayanand Alagappan; Borjan A Gagoski; Vivek K Goyal; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

5.  Slice-selective tunable-flip adiabatic low peak-power excitation pulse.

Authors:  Priti Balchandani; John Pauly; Daniel Spielman
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

6.  Correction for geometric distortion in echo planar images from B0 field variations.

Authors:  P Jezzard; R S Balaban
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

Review 7.  Adiabatic pulses.

Authors:  A Tannús; M Garwood
Journal:  NMR Biomed       Date:  1997-12       Impact factor: 4.044

8.  Magnetic field mapping.

Authors:  J P Hornak; J Szumowski; R G Bryant
Journal:  Magn Reson Med       Date:  1988-02       Impact factor: 4.668

9.  3-D FLASH imaging using a single surface coil and a new adiabatic pulse, BIR-4.

Authors:  R S Staewen; A J Johnson; B D Ross; T Parrish; H Merkle; M Garwood
Journal:  Invest Radiol       Date:  1990-05       Impact factor: 6.016

10.  Theoretical description of depth pulse sequences, on and off resonance, including improvements and extensions thereof.

Authors:  M R Bendall; D T Pegg
Journal:  Magn Reson Med       Date:  1985-04       Impact factor: 4.668

View more
  4 in total

1.  Magnetic resonance imaging of the cervical spinal cord in multiple sclerosis at 7T.

Authors:  Adrienne N Dula; Siddharama Pawate; Richard D Dortch; Robert L Barry; Kristen M George-Durrett; Bailey D Lyttle; Lindsey M Dethrage; John C Gore; Seth A Smith
Journal:  Mult Scler       Date:  2015-07-24       Impact factor: 6.312

2.  Two-dimensional J-resolved LASER and semi-LASER spectroscopy of human brain.

Authors:  Meijin Lin; Anand Kumar; Shaolin Yang
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

3.  Wavelet Domain Radiofrequency Pulse Design Applied to Magnetic Resonance Imaging.

Authors:  Andrew M Huettner; Nikolai J Mickevicius; Ali Ersoz; Kevin M Koch; L Tugan Muftuler; Andrew S Nencka
Journal:  PLoS One       Date:  2015-10-30       Impact factor: 3.240

4.  Hyperpolarized 13 C spectroscopic imaging using single-shot 3D sequences with unpaired adiabatic refocusing pulses.

Authors:  Jiazheng Wang; Richard L Hesketh; Alan J Wright; Kevin M Brindle
Journal:  NMR Biomed       Date:  2018-09-10       Impact factor: 4.044

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.