Literature DB >> 22176886

Wavefront analysis and Zernike polynomial decomposition for evaluation of corneal optical quality.

Cristina M Oliveira1, Andreia Ferreira, Sandra Franco.   

Abstract

Wavefront-guided excimer laser refractive surgery and new customized intraocular lens and contact lens designs are major clinical applications of corneal wavefront analysis. Other therapeutic applications include corneal disorders, conventional excimer laser refractive surgery, incisional techniques and cataract surgery, corneal transplantation, intrastromal corneal ring segment implantation, and crosslinking therapy. Basic data regarding corneal wavefront aberrations, such as distribution in the population and changes with aging, are essential for understanding the nature of each aberration and correcting it. Corneal aberrometry also improved our comprehension of the optical effects of the aforementioned topics while helping us assess the success of the procedures. Zernike polynomials are representations of the higher- and lower-order aberrations of the cornea, allowing a mathematical approach to their determination. Polynomials are used to model individual components of the wavefront in familiar terms. This article reviews the current knowledge of the wavefront aberrations of the human cornea and analyzes studies in the fields of anterior segment surgery and/or therapy, diseases, and optical quality in the context of this knowledge.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22176886     DOI: 10.1016/j.jcrs.2011.11.016

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  15 in total

1.  Corrective Techniques and Future Directions for Treatment of Residual Refractive Error Following Cataract Surgery.

Authors:  Majid Moshirfar; Michael V McCaughey; Luis Santiago-Caban
Journal:  Expert Rev Ophthalmol       Date:  2014-12

2.  Higher order aberrations of the corneal surface after laser subepithelial keratomileusis.

Authors:  Hyun Ho Jung; Yong Sok Ji; Han Jin Oh; Kyung Chul Yoon
Journal:  Korean J Ophthalmol       Date:  2014-07-22

3.  Correlation between visual function and refractive, topographic, pachymetric and aberrometric data in eyes with keratoconus.

Authors:  Neslihan Bayraktar Bilen; Ibrahim F Hepsen; Carlos G Arce
Journal:  Int J Ophthalmol       Date:  2016-08-18       Impact factor: 1.779

4.  A comparable study of clinical and optical outcomes after 1.8, 2.0 mm microcoaxial and 3.0 mm coaxial cataract surgery.

Authors:  Yi-Bo Yu; Ya-Nan Zhu; Wei Wang; Yi-Dong Zhang; Yin-Hui Yu; Ke Yao
Journal:  Int J Ophthalmol       Date:  2016-03-18       Impact factor: 1.779

5.  A pilot study on total, corneal, and internal aberrations in insulin-dependent and non-insulin-dependent diabetes mellitus patients.

Authors:  Ana M Calvo-Maroto; Rafael J Pérez-Cambrodí; Santiago García-Lázaro; César Albarrán-Diego; Alejandro Cerviño
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-11-25       Impact factor: 3.117

6.  Femtosecond laser-assisted cataract surgery versus conventional phacoemulsification: comparison of internal aberrations and visual quality.

Authors:  Yueyang Zhong; Yanan Zhu; Wei Wang; Kai Wang; Xin Liu; Ke Yao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-10-12       Impact factor: 3.117

7.  Visian implantable contact lens versus AcrySof Cachet phakic intraocular lenses: comparison of aberrmetric profiles.

Authors:  Mohamed Hm Hosny; Ahmad Mm Shalaby
Journal:  Clin Ophthalmol       Date:  2013-07-22

8.  Pentacam corneal densitometry-guided treatment of adenoviral corneal subepithelial infiltrates: a comparative study between transepithelial phototherapeutic keratectomy and topical tacrolimus.

Authors:  Tarek Roshdy Elhamaky
Journal:  Int Ophthalmol       Date:  2020-08-27       Impact factor: 2.031

9.  Evaluation of anterior segment parameters and possible influencing factors in normal subjects using a dual Scheimpflug analyzer.

Authors:  Xiaogang Wang; Jing Dong; Qiang Wu
Journal:  PLoS One       Date:  2014-05-16       Impact factor: 3.240

10.  Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients.

Authors:  Yao Chen; Xiaobo Xia
Journal:  BMC Ophthalmol       Date:  2016-03-31       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.