Literature DB >> 2217560

Microlymphatics and lymph flow.

G W Schmid-Schönbein1.   

Abstract

A careful review of several different organs shows that with the information available today the beginnings of the microlymphatics in the tissue consist of endothelialized tubes only. Lymphatic smooth muscle within the collecting lymphatics appears further downstream, in some organs only outside the parenchyma. This particular anatomic picture has been observed in many different mammalian organs and in humans. The nonmuscular, so-called initial, lymphatics are the site of interstitial fluid absorption that requires only small and transient pressure gradients from the interstitium into the initial lymphatics. A fundamental question concerns the mechanism that causes expansion and compression of the initial lymphatics. I presented several realistic proposals based on information currently on hand relevant to the tissue surrounding the initial lymphatics. To achieve a continuous lymphatic output, periodic (time variant) tissue stresses need to be applied. They include arterial pressure pulsations; arteriolar vasomotion; intestinal smooth muscle contractions and motilities; skeletal muscle contraction; skin tension; and external compression, such as during walking, running, or massage, respiration, bronchiole constriction, periodic tension in tendon, contraction and relaxation of the diaphragm, tension in the pleural space during respiration, and contractions of the heart. The nonmuscular initial lymphatic system drains into a set of contractile collecting lymphatics, which by way of intrinsic smooth muscle propel lymph fluid. The exact transition between noncontractile and contractile lymphatics has been established only in a limited number of organs and requires further exploration. Retrograde flow of lymph fluid is prevented by valves. There are the usual macroscopic bileaflet valves in the initial and collecting lymphatics and also microscopic lymphatic endothelial valves on the wall of the initial lymphatics. The latter appear to prevent convective reflow into the interstitium during lymphatic compression. Many of the lymph pump mechanisms have been proposed in the past, and most authors agree that these mechanisms influence lymph flow. However, the decisive experiments have not been carried out to establish to what degree these mechanisms are sufficient to explain lymph flow rates in vivo. Because individual organs have different extrinsic pumps at the level of the initial lymphatics, future experiments need to be designed such that each pump mechanism is examined individually so as to make it possible to evaluate the additive effect on the resultant whole organ lymph flow.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 2217560     DOI: 10.1152/physrev.1990.70.4.987

Source DB:  PubMed          Journal:  Physiol Rev        ISSN: 0031-9333            Impact factor:   37.312


  170 in total

1.  Drainage of plasma proteins from the renal medullary interstitium in rats.

Authors:  O Tenstad; K J Heyeraas; H Wiig; K Aukland
Journal:  J Physiol       Date:  2001-10-15       Impact factor: 5.182

2.  Quantifying the composition of human skin for glucose sensor development.

Authors:  Willemijn Groenendaal; Golo von Basum; Kristiane A Schmidt; Peter A J Hilbers; Natal A W van Riel
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

3.  Differential effects of myosin light chain kinase inhibition on contractility, force development and myosin light chain 20 phosphorylation of rat cervical and thoracic duct lymphatics.

Authors:  Zhanna V Nepiyushchikh; Sanjukta Chakraborty; Wei Wang; Michael J Davis; David C Zawieja; Mariappan Muthuchamy
Journal:  J Physiol       Date:  2011-09-19       Impact factor: 5.182

4.  Molecular characterization of lymphatic endothelial cells.

Authors:  Simona Podgrabinska; Pascal Braun; Paula Velasco; Bryan Kloos; Michael S Pepper; Mihaela Skobe
Journal:  Proc Natl Acad Sci U S A       Date:  2002-11-22       Impact factor: 11.205

5.  Regional heterogeneity of length-tension relationships in rat lymph vessels.

Authors:  Anatoliy A Gashev; Rong-Zhen Zhang; Mariappan Muthuchamy; David C Zawieja; Michael J Davis
Journal:  Lymphat Res Biol       Date:  2012-03-14       Impact factor: 2.589

6.  Tissue contribution to the mechanical features of diaphragmatic initial lymphatics.

Authors:  Andrea Moriondo; Federica Boschetti; Francesca Bianchin; Simone Lattanzio; Cristiana Marcozzi; Daniela Negrini
Journal:  J Physiol       Date:  2010-10-15       Impact factor: 5.182

7.  Characteristic of the active and passive mechanical properties of the lymph node capsule.

Authors:  G I Lobov; M N Pan'kova; D P Dvoretsky; I V Sergeev
Journal:  Dokl Biol Sci       Date:  2010-10-21

Review 8.  From optical bench to cageside: intravital microscopy on the long road to rational vaccine design.

Authors:  Heather D Hickman; Jack R Bennink; Jonathan W Yewdell
Journal:  Immunol Rev       Date:  2011-01       Impact factor: 12.988

9.  Lack of lymphatic vessel phenotype in LYVE-1/CD44 double knockout mice.

Authors:  Mai X Luong; Joshua Tam; Qingcong Lin; Jeroen Hagendoorn; Kathryn J Moore; Timothy P Padera; Brian Seed; Dai Fukumura; Raju Kucherlapati; Rakesh K Jain
Journal:  J Cell Physiol       Date:  2009-05       Impact factor: 6.384

10.  Optical tracer size differences allow quantitation of active pumping rate versus Stokes-Einstein diffusion in lymphatic transport.

Authors:  Alisha V DSouza; Kayla Marra; Jason R Gunn; Kimberley S Samkoe; Brian W Pogue
Journal:  J Biomed Opt       Date:  2016-10-01       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.